Thursday, 24 March 2011 22:53

Active Fire Protection Measures

Life Safety and Property Protection

As the primary importance of any fire protection measure is to provide an acceptable degree of life safety to inhabitants of a structure, in most countries legal requirements applying to fire protection are based on life safety concerns. Property protection features are intended to limit physical damage. In many cases these objectives are complementary. Where concern exists with the loss of property, its function or contents, an owner may choose to implement measures beyond the required minimum necessary to address life safety concerns.

Fire Detection and Alarm Systems

A fire detection and alarm system provides a means to detect fire automatically and to warn building occupants of the threat of fire. It is the audible or visual alarm provided by a fire detection system that is the signal to begin the evacuation of the occupants from the premises. This is especially important in large or multi-storey buildings where occupants would be unaware that a fire was underway within the structure and where it would be unlikely or impractical for warning to be provided by another inhabitant.

Basic elements of a fire detection and alarm system

A fire detection and alarm system may include all or some of the following:

  1. a system control unit
  2. a primary or main electrical power supply
  3. a secondary (stand-by) power supply, usually supplied from batteries or an emergency generator
  4. alarm-initiating devices such as automatic fire detectors, manual pull stations and/or sprinkler system flow devices, connected to “initiating circuits” of the system control unit
  5. alarm-indicating devices, such as bells or lights, connected to “indicating circuits” of the system control unit
  6. ancillary controls such as ventilation shut-down functions, connected to output circuits of the system control unit
  7. remote alarm indication to an external response location, such as the fire department
  8. control circuits to activate a fire protection system or smoke control system.

 

Smoke Control Systems

To reduce the threat of smoke from entering exit paths during evacuation from a structure, smoke control systems can be used. Generally, mechanical ventilation systems are employed to supply fresh air to the exit path. This method is most often used to pressurize stairways or atrium buildings. This is a feature intended to enhance life safety.

Portable Fire Extinguishers and Hose Reels

Portable fire extinguishers and water hose reels are often provided for use by building occupants to fight small fires (see figure 1). Building occupants should not be encouraged to use a portable fire extinguisher or hose reel unless they have been trained in their use. In all cases, operators should be very cautious to avoid placing themselves in a position where safe egress is blocked. For any fire, no matter how small, the first action should always be to notify other building occupants of the threat of fire and summon assistance from the professional fire service.

Figure 1. Portable fire extinguishers.

FIR050F4

Water Sprinkler Systems

Water sprinkler systems consist of a water supply, distribution valves and piping connected to automatic sprinkler heads (see figure 2). While current sprinkler systems are primarily intended to control the spread of fire, many systems have accomplished complete extinguishment.

Figure 2. A typical sprinkler installation showing all common water supplies, outdoor hydrants and underground piping.

FIR050F1

A common misconception is that all automatic sprinkler heads open in the event of a fire. In fact, each sprinkler head is designed to open only when sufficient heat is present to indicate a fire. Water then flows only from the sprinkler head(s) that have opened as the result of fire in their immediate vicinity. This design feature provides efficient use of water for fire-fighting and limits water damage.

 

 

Water supply

Water for an automatic sprinkler system must be available in sufficient quantity and at sufficient volume and pressure at all times to ensure reliable operation in the event of fire. Where a municipal water supply cannot meet this requirement, a reservoir or pump arrangement must be provided to provide a secure water supply.

Control valves

Control valves should be maintained in the open position at all times. Often, supervision of the control valves can be accomplished by the automatic fire alarm system by provision of valve tamper switches that will initiate a trouble or supervisory signal at the fire alarm control panel to indicate a closed valve. If this type of monitoring cannot be provided, the valves should be locked in the open position.

Piping

Water flows through a piping network, ordinarily suspended from the ceiling, with the sprinkler heads suspended at intervals along the pipes. Piping used in sprinkler systems should be of a type that can withstand a working pressure of not less than 1,200 kPa. For exposed piping systems, fittings should be of the screwed, flanged, mechanical joint or brazed type.

Sprinkler heads

A sprinkler head consists of an orifice, normally held closed by a temperature-sensitive releasing element, and a spray deflector. The water discharge pattern and spacing requirements for individual sprinkler heads are used by sprinkler designers to ensure complete coverage of the protected risk.

Special Extinguishing Systems

Special extinguishing systems are used in cases where water sprinklers would not provide adequate protection or where the risk of damage from water would be unacceptable. In many cases where water damage is of concern, special extinguishing systems may be used in conjunction with water sprinkler systems, with the special extinguishing system designed to react at an early stage of fire development.

Water and water-additive special extinguishing systems

Water spray systems

Water spray systems increase the effectiveness of water by producing smaller water droplets, and thus a greater surface area of water is exposed to the fire, with a relative increase in heat absorption capability. This type of system is often chosen as a means of keeping large pressure vessels, such as butane spheres, cool when there is a risk of an exposure fire originating in an adjacent area. The system is similar to a sprinkler system; however, all heads are open, and a separate detection system or manual action is used to open control valves. This allows water to flow through the piping network to all spray devices that serve as outlets from the piping system.

Foam systems

In a foam system, a liquid concentrate is injected into the water supply before the control valve. Foam concentrate and air are mixed, either through the mechanical action of discharge or by aspirating air into the discharge device. The air entrained in the foam solution creates an expanded foam. As expanded foam is less dense than most hydrocarbons, the expanded foam forms a blanket on top of the flammable liquid. This foam blanket reduces fuel vapour propagation. Water, which represents as much as 97% of the foam solution, provides a cooling effect to further reduce vapour propagation and to cool hot objects that could serve as a source of re-ignition.

Gaseous extinguishing systems

Carbon dioxide systems

Carbon dioxide systems consist of a supply of carbon dioxide, stored as liquified compressed gas in pressure vessels (see figures 3 and 4). The carbon dioxide is held in the pressure vessel by means of an automatic valve that is opened upon fire by means of a separate detection system or by manual operation. Once released, the carbon dioxide is delivered to the fire by means of a piping and discharge nozzle arrangement. Carbon dioxide extinguishes fire by displacing the oxygen available to the fire. Carbon dioxide systems can be designed for use in open areas such as printing presses or enclosed volumes such as ship machinery spaces. Carbon dioxide, at fire-extinguishing concentrations, is toxic to people, and special measures must be employed to ensure that persons in the protected area are evacuated before discharge occurs. Pre-discharge alarms and other safety measures must be carefully incorporated into the design of the system to ensure adequate safety for people working in the protected area. Carbon dioxide is considered to be a clean extinguishant because it does not cause collateral damage and is electrically non-conductive.

Figure 3. Diagram of a high-pressure carbon dioxide system for total flooding.

FIR050F2

 

Figure 4. A total flooding system installed in a room with a raised floor.

FIR050F3

Inert gas systems

Inert gas systems generally use a mixture of nitrogen and argon as an extinguishing medium. In some cases, a small percentage of carbon dioxide is also provided in the gas mixture. The inert gas mixtures extinguish fires by reducing oxygen concentration within a protected volume. They are suitable for use in enclosed spaces only. The unique feature offered by inert gas mixtures is that they reduce the oxygen to a low enough concentration to extinguish many types of fires; however, oxygen levels are not sufficiently lowered to pose an immediate threat to occupants of the protected space. The inert gases are compressed and stored in pressure vessels. System operation is similar to a carbon dioxide system. As the inert gases cannot be liquefied by compression, the number of storage vessels required for protection of a given enclosed protected volume is greater than that for carbon dioxide.

Halon systems

Halons 1301, 1211 and 2402 have been identified as ozone-depleting substances. Production of these extinguishing agents ceased in 1994, as required by the Montreal Protocol, an international agreement to protect the earth’s ozone layer. Halon 1301 was most often used in fixed fire protection systems. Halon 1301 was stored as liquefied, compressed gas in pressure vessels in a similar arrangement to that used for carbon dioxide. The advantage offered by halon 1301 was that storage pressures were lower and that very low concentrations provided effective extinguishing capability. Halon 1301 systems were used successfully for totally enclosed hazards where the extinguishing concentration achieved could be maintained for a sufficient time for extinguishment to occur. For most risks, concentrations used did not pose an immediate threat to occupants. Halon 1301 is still used for several important applications where acceptable alternatives have yet to be developed. Examples include use on-board commercial and military aircraft and for some special cases where inerting concentrations are required to prevent explosions in areas where occupants could be present. The halon in existing halon systems that are no longer required should be made available for use by others with critical applications. This will militate against the need to produce more of these environmentally sensitive extinguishers and help protect the ozone layer.

Halocarbon systems

Halocarbon agents were developed as the result of the environmental concerns associated with halons. These agents differ widely in toxicity, environmental impact, storage weight and volume requirements, cost and availability of approved system hardware. They all can be stored as liquefied compressed gases in pressure vessels. System configuration is similar to a carbon dioxide system.

Design, Installation and Maintenance of Active Fire Protection Systems

Only those skilled in this work are competent to design, install and maintain this equipment. It may be necessary for many of those charged with purchasing, installing, inspecting, testing, approving and maintaining this equipment to consult with an experienced and competent fire protection specialist to discharge their duties effectively.

Further Information

This section of the Encyclopaedia presents a very brief and limited overview of the available choice of active fire protection systems. Readers may often obtain more information by contacting a national fire protection association, their insurer or the fire prevention department of their local fire service.

 

Back

This article describes several significant radiation accidents, their causes and the responses to them. A review of the events leading up to, during and following these accidents can provide planners with information to preclude future occurrences of such accidents and to enhance an appropriate, rapid response in the event a similar accident occurs again.

Acute Radiation Death Resulting from an Accidental Nuclear Critical Excursion on 30 December 1958

This report is noteworthy because it involved the largest accidental dose of radiation received by humans (to date) and because of the extremely professional and thorough work-up of the case. This represents one of the best, if not the best, documented acute radiation syndrome descriptions that exists (JOM 1961).

At 4:35 p.m. on 30 December 1958, an accidental critical excursion resulting in fatal radiation injury to an employee (K) took place in the plutonium recovery plant at the Los Alamos National Laboratory (New Mexico, United States).

The time of the accident is important because six other workers had been in the same room with K thirty minutes earlier. The date of the accident is important because the normal flow of fissionable material into the system was interrupted for year-end physical inventory. This interruption caused a routine procedure to become non-routine and led to an accidental “criticality” of the plutonium-rich solids that were accidentally introduced into the system.

Summary of estimates of K’s radiation exposure

The best estimate of K’s average total-body exposure was between 39 and 49 Gy, of which about 9 Gy was due to fission neutrons. A considerably greater portion of the dose was delivered to the upper half of the body than to the lower half. Table 1 shows an estimate of K’s radiation exposure.

Table 1. Estimates of K’s radiation exposure

Region and conditions

Fast neutron
absorbed dose (Gy)

Gamma
absorbed dose (Gy)

Total
absorbed dose (Gy)

Head (incident)

26

78

104

Upper abdomen
(incident)

30

90

124

Total body (average)

9

30-40

39-49

 

Clinical course of patient

In retrospect, the clinical course of patient K can be divided into four distinct periods. These periods differed in duration, symptoms and response to supportive therapy.

The first period, lasting from 20 to 30 minutes, was characterized by his immediate physical collapse and mental incapacitation. His condition progressed to semi-consciousness and severe prostration.

The second period lasted about 1.5 hours and began with his arrival by stretcher at the emergency room of the hospital and ended with his transfer from the emergency room to the ward for further supportive therapy. This interval was characterized by such severe cardiovascular shock that death seemed imminent during the whole time. He seemed to be suffering severe abdominal pain.

The third period was about 28 hours long and was characterized by enough subjective improvement to encourage continued attempts to alleviate his anoxia, hypotension and circulatory failure.

The fourth period began with the unheralded onset of rapidly increasing irritability and antagonism, bordering on mania, followed by coma and death in approximately 2 hours. The entire clinical course lasted 35 hours from the time of radiation exposure to death.

The most dramatic clinicopathological changes were observed in the haemopoietic and urinary systems. Lymphocytes were not found in the circulating blood after the eighth hour, and there was virtually complete urinary shutdown despite administration of large amount of fluids.

K’s rectal temperature varied between 39.4 and 39.7°C for the first 6 hours and then fell precipitously to normal, where it remained for the duration of his life. This high initial temperature and its maintenance for 6 hours were considered in keeping with his suspected massive dose of radiation. His prognosis was grave.

Of all the various determinations made during the course of the illness, changes in white cell count were found to be the simplest and best prognostic indicator of severe irradiation. The virtual disappearance of lymphocytes from the peripheral circulation within 6 hours of exposure was considered a grave sign.

Sixteen different therapeutic agents were employed in the symptomatic treatment of K over about a 30-hour period. In spite of this and continued oxygen administration, his heart tones became very distant, slow and irregular about 32 hours after irradiation. His heart then became progressively weaker and suddenly stopped 34 hours 45 minutes after irradiation.

Windscale Reactor No. 1 Accident of 9-12 October 1957

Windscale reactor No. 1 was an air-cooled, graphite-moderated natural uranium-fuelled plutonium production reactor. The core was partially ruined by fire on 15 October 1957. This fire resulted in a release of approximately 0.74 PBq (10+15 Bq) of iodine-131 (131I) to the downwind environment.

According to a US Atomic Energy Commission accident information report about the Windscale incident, the accident was caused by operator judgement errors concerning thermocouple data and was made worse by faulty handling of the reactor that permitted the graphite temperature to rise too rapidly. Also contributory was the fact that fuel temperature thermocouples were located in the hottest part of the reactor (that is, where the highest dose rates occurred) during normal operations rather than in parts of the reactor which were hottest during an abnormal release. A second equipment deficiency was the reactor power meter, which was calibrated for normal operations and read low during the annealing. As a result of the second heating cycle, the graphite temperature rose on 9 October, especially in the lower front part of the reactor where some cladding had failed because of the earlier rapid temperature rise. Although there were a number of small iodine releases on 9 October, the releases were not recognized until 10 October when the stack activity meter showed a significant increase (which was not regarded as highly significant). Finally, on the afternoon of 10 October, other monitoring (Calder site) indicated the release of radioactivity. Efforts to cool the reactor by forcing air through it not only failed but actually increased the magnitude of the radioactivity released.

The estimated releases from the Windscale accident were 0.74 PBq of 131I, 0.22 PBq of caesium-137 (137Cs), 3.0 TBq (1012Bq) of strontium-89 (89Sr), and 0.33 TBq of strontium-90
(90Sr). The highest offsite gamma absorbed dose rate was about 35 μGy/h due to airborne activity. Air activity readings around the Windscale and Calder plants often were 5 to 10 times the maximum permissible levels, with occasional peaks of 150 times permissible levels. A milk ban extended over a radius of approximately 420 km.

During operations to bring the reactor under control, 14 workers received dose equivalents greater than 30 mSv per calendar quarter, with the maximum dose equivalent at 46 mSv per calendar quarter.

Lessons learned

There were many lessons learned concerning natural uranium reactor design and operation. The inadequacies concerning reactor instrumentation and reactor operator training also bring up points analogous to the Three Mile Island accident (see below).

No guidelines existed for short-term permissible exposure to radioiodine in food. The British Medical Research Council performed a prompt and thorough investigation and analysis. Much ingenuity was used in promptly deriving maximum permissible concentrations for 131I in food. The study Emergency Reference Levels that resulted from this accident serves as a basis for emergency planning guides now used worldwide (Bryant 1969).

A useful correlation was derived for predicting significant radioiodine contamination in milk. It was found that gamma radiation levels in pastures which exceeded 0.3 μGy/h yielded milk which exceeded 3.7 MBq/m3.

Absorbed dose from inhalation of external exposure to radioiodines is negligible compared to that from drinking milk or eating dairy products. In an emergency, rapid gamma spectroscopy is preferable to slower laboratory procedures.

Fifteen two-person teams performed radiation surveys and obtained samples. Twenty persons were used for sample coordination and data reporting. About 150 radiochemists were involved in sampling analysis.

Glass wool stack filters are not satisfactory under accident conditions.

Gulf Oil Accelerator Accident of 4 October 1967

Gulf Oil Company technicians were using a 3 MeV Van de Graaff accelerator for the activation of soil samples on 4 October 1967. The combination of an interlock failure on the power key of the accelerator console and the taping of several of the interlocks on the safety tunnel door and the target room inside door produced serious accidental exposures to three individuals. One individual received approximately 1 Gy whole-body dose equivalent, the second received close to 3 Gy whole-body dose equivalent and the third received approximately 6 Gy whole-body dose equivalent, in addition to approximately 60 Gy to the hands and 30 Gy to the feet.

One of the accident victims reported to the medical department, complaining of nausea, vomiting and generalized muscular aches. His symptoms initially were misdiagnosed as flu symptoms. When the second patient came in with approximately the same symptoms, it was decided that they may possibly have received significant radiation exposures. Film badges verified this. Dr. Niel Wald, University of Pittsburgh Radiological Health Division, supervised the dosimetry tests and also acted as coordinating physician in the work-up and treatment of the patients.

Dr. Wald very quickly had absolute filter units flown in to the western Pennsylvania hospital in Pittsburgh where the three patients had been admitted. He set up these absolute filter/laminar flow filters to clean the patients’ environment of all biological contaminants. These “reverse isolation” units were used on the 1 Gy exposure patient for about 16 days, and on the 3 and 6 Gy exposure patients for about a month and half.

Dr. E. Donnal Thomas from the University of Washington arrived to perform a bone marrow transplant on the 6 Gy patient on the eighth day after exposure. The patient’s twin brother served as the bone marrow donor. Although this heroic medical treatment saved the 6 Gy patient’s life, nothing could be done to save his arms and legs, each of which received tens-of-gray absorbed dose.

Lessons learned

If the simple operating procedure of always using a survey meter when entering the exposure room had been followed, this tragic accident would have been avoided.

At least two interlocks had been taped closed for long periods of time prior to this accident. Defeating of protective interlocks is intolerable.

Regular maintenance checks should have been made on the key-operated power interlocks for the accelerator.

Timely medical attention saved the life of the person with the highest exposure. The heroic procedure of a complete bone marrow transplant together with the use of reverse isolation and quality medical care were all major factors in saving this person’s life.

Reverse isolation filters can be obtained in a matter of hours to be set up in any hospital to care for highly exposed patients.

In retrospect, medical authorities involved with these patients would have recommended amputation earlier and at a definitive level within two or three months after the exposure. Earlier amputation decreases the likelihood of infection, gives a shorter period of severe pain, reduces pain medication required for the patient, possibly reduces the patient’s hospital stay, and possibly contributes to earlier rehabilitation. Earlier amputation should, of course, be done while correlating dosimetry information with clinical observations.

The SL–1 Prototype Reactor Accident (Idaho, USA, 3 January 1961)

This is the first (and to date the only) fatal accident in the history of US reactor operations. The SL-1 is a prototype of a small Army Package Power Reactor (APPR) designed for air transportation to remote areas for production of electrical power. This reactor was used for fuel testing, and for reactor crew training. It was operated in the remote desert location of the National Reactor Testing Station in Idaho Falls, Idaho, by Combustion Engineering for the US Army. The SL-1 was not a commercial power reactor (AEC 1961; American Nuclear Society 1961).

At the time of the accident, the SL-1 was loaded with 40 fuel elements and 5 control rod blades. It could produce a power level of 3 MW (thermal) and was a boiling water–cooled and –moderated reactor.

The accident resulted in the deaths of three military personnel. The accident was caused by the withdrawal of a single control rod for a distance of more than 1 m. This caused the reactor to go into prompt criticality. The reason why a skilled, licensed reactor operator with much refuelling operation experience withdrew the control rod past its normal stop point is unknown.

One of the three accident victims was still alive when initial response personnel first reached the scene of the accident. High activity fission products covered his body and were embedded in his skin. Portions of the victim’s skin registered in excess of 4.4 Gy/h at 15 cm and hampered rescue and medical treatment.

Lessons learned

No reactor designed since the SL-1 accident can be brought to “prompt-critical” state with a single control rod.

All reactors must have portable survey meters onsite that have ranges greater than 20 mGy/h. Survey meters of 10 Gy/h maximum range are recommended.

Note: The Three Mile Island accident showed that 100 Gy/h is the required range for both gamma and beta measurements.

Treatment facilities are required where a highly contaminated patient can receive definitive medical treatment with reasonable safeguards for attendant personnel. Since most of these facilities will be in clinics with other ongoing missions, control of airborne and waterborne radioactive contaminants may require special provisions.

X-ray Machines, Industrial and Analytical

Accidental exposures from x-ray systems are numerous and often involve extremely high exposures to small portions of the body. It is not unusual for x-ray diffraction systems to produce absorbed dose rates of 5 Gy/s at 10 cm from the tube focus. At shorter distances, 100 Gy/s rates have often been measured. The beam is usually narrow, but even a few seconds’ exposure can result in severe local injury (Lubenau et al. 1967; Lindell 1968; Haynie and Olsher 1981; ANSI 1977).

Because these systems are often used in “non-routine” circumstances, they lend themselves to the production of accidental exposures. X-ray systems commonly used in normal operations appear to be reasonably safe. Equipment failure has not caused severe exposures.

Lessons learned from accidental x-ray exposures

Most accidental exposures occurred during non-routine uses when equipment was partially disassembled or shield covers had been removed.

In most serious exposures, adequate instruction for the staff and maintenance personnel had been lacking.

If simple and fail-safe methods had been used to ensure that x-ray tubes were turned off during repairs and maintenance, many accidental exposures would have been avoided.

Finger or wrist personnel dosimeters should be used for operators and maintenance personnel working with these machines.

If interlocks had been required, many accidental exposures would have been avoided.

Operator error was a contributing cause in most of the accidents. Lack of adequate enclosures or poor shielding design often worsened the situation.

Industrial radiography accidents

From the 1950s through the 1970s, the highest radiation accident rate for a single activity has consistently been for industrial radiographic operations (IAEA 1969, 1977). National regulatory bodies continue to struggle to reduce the rate by a combination of improved regulations, strict training requirements and ever tougher inspection and enforcement policies (USCFR 1990). These regulatory efforts have generally succeeded, but many accidents associated with industrial radiography still occur. Legislation allowing huge monetary fines may be the most effective tool in keeping radiation safety focused in the minds of industrial radiography management (and also, therefore, in workers’ minds).

Causes of industrial radiography accidents

Worker training. Industrial radiography probably has lower education and training requirements than any other type of radiation employment. Therefore, existing training requirements must be strictly enforced.

Worker production incentive. For years, major emphasis for industrial radiographers was placed on the amount of successful radiographs produced per day. This practice can lead to unsafe acts as well as to occasional non-use of personnel dosimetry so that exceeding dose equivalent limits would not be detected.

Lack of proper surveys. Thorough surveying of source pigs (storage containers) (figure 1) after every exposure is most important. Not performing these surveys is the single most probable cause of unnecessary exposures, many of which are unrecorded, since industrial radiographers rarely use hand or finger dosimeters (figure 1).

Figure 1. Industrial radiography camera

ION060F1

Equipment problems. Because of heavy use of industrial radiographic cameras, source winding mechanisms can loosen and cause the source to not completely retract into its safe storage position (point A in figure 1). There are also many instances of closet-source interlock failures that cause accidental exposures of personnel.

Design of Emergency Plans

Many excellent guidelines, both general and specific, exist for the design of emergency plans. Some references are particularly helpful. These are given in the suggested readings at the end of this chapter.

Initial drafting of emergency plan and procedures

First, one must assess the entire radioactive material inventory for the subject facility. Then credible accidents must be analysed so that one can determine the probable maximum source release terms. Next, the plan and its procedures must enable the facility operators to:

    1. recognize an accident situation
    2. classify the accident according to severity
    3. take steps to mitigate the accident
    4. make timely notifications
    5. call for help efficiently and quickly
    6. quantify releases
    7. keep track of exposures both on- and offsite, as well as keep emergency exposures ALARA
    8. recover the facility as quickly as practical
    9. keep accurate and detailed records.

                     

                    Types of accidents associated with nuclear reactors

                    A list, from most likely to least likely, of types of accidents associated with nuclear reactors follows. (The non-nuclear reactor, general-industrial type accident is by far the most likely.)

                      1. Low level unexpected release of radioactive material with little or no external radiation exposure to personnel. Usually occurs during major overhauls or in shipment of spent resin or spent fuel. Coolant system leakage and coolant-sample sink spills are often causes of spread of radioactive contamination.
                      2. Unexpected external exposure of personnel. This usually occurs during major overhauls or routine maintenance.
                      3. A combination of contamination spread, contamination of personnel, and low-level personnel external radiation exposure is the next most likely accident. These accidents occur under the same conditions as 1 and 2 above.
                      4. Gross surface contamination due to a major reactor coolant system leak or a leak of spent fuel coolant.
                      5. Chips or large particles of activated CRUD (see definition below) in or on skin, ears or eyes.
                      6. High-level radiation exposure of plant personnel. This is usually caused by carelessness.
                      7. Release of small but greater than permissible quantities of radioactive wastes to outside the plant boundary. This is usually associated with human failures.
                      8. Meltdown of reactor. Gross contamination offsite plus high personnel exposure would probably occur.
                      9. Reactor excursion (SL–1 type of accident).

                                       

                                      Radionuclides expected from water-cooled reactor accidents:

                                        • activated corrosion and erosion products (commonly known as CRUD) in the coolant; for example, cobalt-60 or -58 (60Co, 58Co), iron-59 (59Fe), manganese-58 (58Mn) and tantalum-183 (183Ta)
                                        • low level fission products usually present in the coolant; for example, iodine-131 (131I) and caesium-137 (137Cs)
                                        • in boiling water reactors, 1 and 2 above plus continuous off-gassing of low levels of tritium 
                                        • (3H) and noble radioactive gases such as xenon-133 and -135 (133Xe, 135Xe), argon-41 (41Ar), and krypton-85 (85Kr)
                                        • tritium (3H) manufactured inside the core at the rate of 1.3 × 10–4 atoms of 3H per fission (only a fraction of this leaves the fuel).

                                              Figure 2. Example of a nuclear power plant emergency plan, table of contents

                                              ION060T2

                                              Typical Nuclear Power Plant Emergency Plan, Table of Contents

                                              Figure 2 is an example of a table of contents for a nuclear power plant emergency plan. Such a plan should include each chapter shown and be tailored to meet local requirements. A list of typical power reactor implementation procedures is given in figure 3.

                                              Figure 3. Typical power reactor implementation procedures

                                              ION060F5

                                              Radiological Environmental Monitoring during Accidents

                                              This task is often called EREMP (Emergency Radiological Environmental Monitoring Programme) at large facilities.

                                              One of the most important lessons learned for the US Nuclear Regulatory Commission and other government agencies from the Three Mile Island accident was that one cannot successfully implement EREMP in one or two days without extensive prior planning. Although the US government spent many millions of dollars monitoring the environment around the Three Mile Island nuclear station during the accident, less then 5% of the total releases were measured. This was due to poor and inadequate prior planning.

                                              Designing Emergency Radiological Environmental Monitoring Programmes

                                              Experience has shown that the only successful EREMP is one that is designed into the routine radiological environmental monitoring programme. During the early days of the Three Mile Island accident, it was learned that an effective EREMP cannot be established successfully in a day or two, no matter how much manpower and money are applied to the programme.

                                              Sampling locations

                                              All routine radiological environmental monitoring programme locations will be used during long-term accident monitoring. In addition, a number of new locations must be set up so that motorized survey teams have pre-determined locations in each portion of each 22½° sector (see figure 3). Generally, sampling locations will be in areas with roads. However, exceptions must be made for normally inaccessible but potentially occupied sites such as camp grounds and hiking trails within about 16 km downwind of the accident.

                                              Figure 3. Sector and zone designations for radiological sampling and monitoring points  within emergency planning zones

                                              ION060F4

                                              Figure 3 shows the sector and zone designation for radiation and environmental monitoring points. One may designate 22½° sectors by cardinal directions (for example, N, NNE, and NE) or by simple letters (for example, A through R). However, use of letters is not recommended because they are easily confused with directional notation. For example, it is less confusing to use the directional W for west rather than the letter N.

                                              Each designated sample location should be visited during a practice drill so that people responsible for monitoring and sampling will be familiar with the location of each point and will be aware of radio “dead spaces,” poor roads, problems with finding the locations in the dark and so on. Since no drill will cover all the pre-designated locations within the 16 km emergency protection zone, drills must be designed so that all sample points will be visited eventually. It is often worthwhile to predetermine the ability of survey team vehicles to communicate with each pre-designated point. The actual locations of the sample points are chosen utilizing the same criteria as in the REMP (NRC 1980); for example, line of site, minimum exclusion area, closest individual, closest community, closest school, hospital, nursing home, milch animal herd, garden, farm and so                                                                                                                     on.

                                              Radiological monitoring survey team

                                              During an accident involving significant releases of radioactive materials, radiological monitoring teams should be continuously monitoring in the field. They also should continuously monitor onsite if conditions allow. Normally, these teams will monitor for ambient gamma and beta radiation and sample air for the presence of radioactive particulates and halogens.

                                              These teams must be well trained in all monitoring procedures, including monitoring their own exposures, and be able to accurately relay these data to the base station. Details such as survey-meter type, serial number, and open-or closed-window status must be carefully reported on well-designed log sheets.

                                              At the beginning of an emergency, an emergency monitoring team may have to monitor for 12 hours without a break. After the initial period, however, field time for the survey team should be decreased to eight hours with at least one 30 minute break.

                                              Since continuous surveillance may be needed, procedures must be in place to supply the survey teams with food and drink, replacement instruments and batteries, and for back-and-forth transfer of air filters.

                                              Even though survey teams will probably be working 12 hours per shift, three shifts a day are needed to provide continuous surveillance. During the Three Mile Island accident, a minimum of five monitoring teams was deployed at any one time for the first two weeks. The logistics for supporting such an effort must be carefully planned in advance.

                                              Radiological environmental sampling team

                                              The types of environmental samples taken during an accident depend on the type of releases (airborne versus water), direction of the wind and time of year. Soil and drinking water samples must be taken even in winter. Although radio-halogen releases may not be detected, milk samples should be taken because of the large bioaccumulation factor.

                                              Many food and environmental samples must be taken to reassure the public even though technical reasons may not justify the effort. In addition, these data may be invaluable during any subsequent legal proceedings.

                                              Pre-planned log sheets using carefully thought out offsite data procedures are essential for environmental samples. All persons taking environmental samples should have demonstrated a clear understanding of procedures and have documented field training.

                                              If possible, offsite environmental sample data collection should be done by an independent offsite group. It is also preferable that routine environmental samples be taken by the same offsite group, so that the valuable onsite group may be used for other data collection during an accident.

                                              It is notable that during the Three Mile Island accident every single environmental sample that should have been taken was collected, and not one environmental sample was lost. This occurred even though the sampling rate increased by a factor of more than ten over pre-accident sampling rates.

                                              Emergency monitoring equipment

                                              The inventory of emergency monitoring equipment should be at least double that needed at any given time. Lockers should be placed around nuclear complexes in various places so that no one accident will deny access to all of these lockers. To ensure readiness, equipment should be inventoried and its calibration checked at least twice a year and after each drill. Vans and trucks at large nuclear facilities should be completely outfitted for both on and offsite emergency surveillance.

                                              Onsite counting laboratories may be unusable during an emergency. Therefore, prior arrangements must be made for an alternate or a mobile counting laboratory. This is now a requirement for US nuclear power plants (USNRC 1983).

                                              The type and sophistication of environmental monitoring equipment should meet the requirements of attending the nuclear facility’s worst credible accident. Following is a list of typical environmental monitoring equipment required for nuclear power plants:

                                                1. Air sampling equipment should include units which are battery operated for short-term sampling and AC operable with strip chart recorders and alarm capabilities for longer-term surveillance.
                                                2. Liquid sampling equipment should contain continuous samplers. The samplers must be operable in the local environment, no matter how harsh it is.
                                                3. Portable gamma survey meters for implant work should have a maximum range of 100 Gy/h, and separate survey equipment should be able to measure beta radiation up to 100 Gy/h.
                                                4. Onsite, personnel dosimetry must include beta measurement capability, as well as finger thermoluminescent dosimeters (TLDs) (figure 4). Other extremity dosimetry also may be needed. Extra sets of control dosimeters are always needed in emergencies. A portable TLD reader may be needed to link with the station computer via telephone modem in emergency locations. In-house survey teams, such as rescue and repair teams, should have low- and high-range pocket dosimeters as well as pre-set alarm dosimeters. Careful thought must be given to pre-established dose levels for teams that may be in high radiation areas.
                                                5. Supplies of protective clothing should be supplied in emergency locations and in emergency vehicles. Extra back-up protective clothing should be available in case of accidents lasting for an extended period of time.
                                                6. Respiratory protection equipment should be in all emergency lockers and vehicles. Up-to-date lists of respiratory trained personnel should be kept in each of the major emergency equipment storage areas.
                                                7. Mobile vehicles equipped with radios are essential for emergency radiation monitoring survey teams. The location and availability of back-up vehicles must be known.
                                                8. Environmental survey team equipment should be stored in a convenient place, preferably offsite, so that it is always available.
                                                9. Emergency kits should be placed in the Technical Support Center and the Emergency Offsite Facility so that replacement survey teams need not go onsite in order to receive equipment and be deployed.
                                                10. For a severe accident involving the release of radioactive materials into the air, preparations must be in place for the use of helicopters and single-engine airplanes for airborne surveillance.

                                                                 

                                                                Figure 4. An industrial radiographer wearing a TLD badge and a ring thermoluminescent dosimeter (optional in the US)

                                                                ION060F2

                                                                Data analysis

                                                                Environmental data analysis during a serious accident should be shifted as soon as possible to an offsite location such as the Emergency Offsite Facility.

                                                                Pre-set guidelines about when environmental sample data are to be reported to management must be established. The method and frequency for transfer of environmental sample data to governmental agencies should be agreed upon early in the accident.

                                                                Health Physics and Radiochemistry Lessons Learned from the Three Mile Island Accident

                                                                Outside consultants were needed to perform the following activities because plant health physicists were fully occupied by other duties during the early hours of the 28 March 1979 Three Mile Island accident:

                                                                  • radioactive effluent release assessment (gaseous and liquid), including sample collection, coordination of laboratories for sample counting, quality control of laboratories, data collection, data analysis, report generation, distribution of data to government agencies and power plant owner
                                                                  • dose assessment, including suspected and actual overexposure investigations, skin contamination and internal deposition investigations, significant exposure mock-ups, and dose calculations
                                                                  • radiological environmental monitoring programme, including complete coordination of sample taking, data analysis, report generation and distribution, action-point notifications, expansion of programme for the accident situation and then contraction of the programme for up to one year after the accident
                                                                  • special beta dosimetry studies, including studies of the state of the art in beta personnel monitoring, modelling of the beta dose to skin from radioactive contaminants, inter-comparisons of all commercially available beta-gamma TLD personnel dosimetry systems.

                                                                         

                                                                        The above list includes examples of activities that the typical utility health physics staff cannot adequately accomplish during a serious accident. The Three Mile Island health physics staff was very experienced, knowledgeable and competent. They worked 15 to 20 hours per day for the first two weeks of the accident without a break. Yet, additional requirements caused by the accident were so numerous that they were unable to perform many important routine tasks that ordinarily would be performed easily.

                                                                        Lessons learned from the Three Mile Island accident include:

                                                                        Auxiliary building entry during accident

                                                                          1. All entries must be on a new radiation work permit reviewed by the senior health physicist onsite and signed by the unit superintendent or designated alternate.
                                                                          2. The appropriate control room should have absolute control over all Auxiliary and Fuel Handling Building entries. No entries must be allowed unless a health physicist is at the control point during the entry.
                                                                          3. No entries without a properly operating survey meter of appropriate range should be allowed. A spot check of meter response should be performed immediately prior to entry.
                                                                          4. Exposure history for all persons prior to their entry into a high radiation area must be obtained.
                                                                          5. Allowable exposures during entry, no matter how important the task should be designated.

                                                                           

                                                                          Primary coolant sampling during accident

                                                                            1. All samples to be taken on a new radiation work permit should be reviewed by the senior health physicist onsite and signed by the unit superintendent or alternate.
                                                                            2. No coolant samples should be taken unless an extremity dosimeter is worn.
                                                                            3. No coolant samples should be taken without the availability of shielded gloves and tongs at least 60 cm long in case a sample is more radioactive than expected.
                                                                            4. No coolant samples should be taken without a leaded-glass personnel shield in place in case a sample is more radioactive than expected.
                                                                            5. Sample-taking should be discontinued if the exposure to an extremity or to the whole-body is likely to exceed pre-set levels stated on the radiation work permit.
                                                                            6. Significant exposures should be distributed among a number of workers if possible.
                                                                            7. All cases of skin contamination in excess of action levels within 24 hours should be reviewed.

                                                                                         

                                                                                        Make-up valve room entry

                                                                                          1. Beta and gamma area surveys using remote detectors with appropriate maximum range must be performed.
                                                                                          2. Initial entry in an area with an absorbed dose rate of more than 20 mGy/h must have prior review to verify that exposure to radiation will be kept as low as reasonably achievable.
                                                                                          3. When water leaks are suspected, possible floor contamination should be detected.
                                                                                          4. A consistent programme for type and placement of personnel dosimetry must be put into operation.
                                                                                          5. With persons entering an area with an absorbed dose rate of more than 20 mGy/h, TLDs must be assessed immediately after exit.
                                                                                          6. It should be verified that all radiation work permit requirements are being carried out prior to entry into an area with an absorbed dose rate of more than 20 mGy/h.
                                                                                          7. Controlled-time entries into hazardous areas must be timed by a health physicist.

                                                                                                       

                                                                                                      Protective actions and offsite environmental surveillance from the local government’s perspective

                                                                                                      1. Before beginning a sampling protocol, criteria for stopping it should be established.
                                                                                                      2. Outside interference should not be allowed.
                                                                                                      3. Several confidential telephone lines should be in place. The numbers should be changed after each crisis.
                                                                                                      4. The capabilities of aerial measuring systems are better than most people think they are.
                                                                                                      5. A tape recorder should be in hand and data recorded regularly.
                                                                                                      6. While the acute episode is in progress, the reading of newspapers, watching television and listening to the radio should be abandoned as these activities only add to existing tensions.
                                                                                                      7. Food delivery and other comforts such as sleeping facilities should be planned for as it may be impossible to go home for a while.
                                                                                                      8. Alternate analytic capabilities should be planned for. Even a small accident can alter laboratory background radiation levels significantly.
                                                                                                      9. It should be noted that more energy will be expended in heading off unsound decisions than in dealing with real problems.
                                                                                                      10. It should be understood that emergencies cannot be managed from remote locations.
                                                                                                      11. It should be noted that protective action recommendations are not amenable to committee vote.
                                                                                                      12. All non-essential calls should be put on hold, time-wasters are to be hung up on.

                                                                                                                     

                                                                                                                    The Goiânia Radiological Accident of 1985

                                                                                                                    A 51 TBq 137Cs teletherapy unit was stolen from an abandoned clinic in Goiânia, Brazil, on or around 13 September 1985. Two people looking for scrap metal took home the source assembly of the teletherapy unit and attempted to disassemble the parts. The absorbed dose rate from the source assembly was about 46 Gy/h at 1 m. They did not understand the meaning of the three-bladed radiation symbol on the source capsule.

                                                                                                                    The source capsule ruptured during disassembly. Highly soluble caesium-137 chloride (137CsCl) powder was disbursed throughout a part of this city of 1,000,000 people and caused one of the most serious sealed source accidents in history.

                                                                                                                    After the disassembly, remnants of the source assembly were sold to a junk dealer. He discovered that the 137CsCl powder glowed in the dark with a blue colour (presumably, this was Cerenkov radiation). He thought that the powder could be a gemstone or even supernatural. Many friends and relatives came to see the “wonderful” glow. Portions of the source were given to a number of families. This process continued for about five days. By this time a number of people had developed gastro-intestinal syndrome symptoms from radiation exposure.

                                                                                                                    Patients who went to the hospital with severe gastro-intestinal disorders were misdiagnosed as having allergic reactions to something they ate. A patient who had severe skin effects from handling the source was suspected of having some tropical skin disease and was sent to the Tropical Disease Hospital.

                                                                                                                    This tragic sequence of events continued undetected by knowledgeable personnel for about two weeks. Many people rubbed the 137CsCl powder on their skins so that they could glow blue. The sequence might have continued much longer except that one of the irradiated persons finally connected the illnesses with the source capsule. She took the remnants of the 137CsCl source on a bus to the Public Health Department in Goiânia where she left it. A visiting medical physicist surveyed the source the next day. He took actions on his own initiative to evacuate two junkyard areas and to inform authorities. The speed and overall size of response of the Brazilian government, once it became aware of the accident, were impressive.

                                                                                                                    About 249 people were contaminated. Fifty-four were hospitalized. Four people died, one of whom was a six-year-old girl who received an internal dose of about 4 Gy from ingesting about 1 GBq (109 Bq) of 137Cs.

                                                                                                                    Response to the accident

                                                                                                                    The objectives of the initial response phase were to:

                                                                                                                      • identify the main sites of contamination
                                                                                                                      • evacuate residences where levels of radioactivity exceeded the intervention levels adopted
                                                                                                                      • establish health physics controls around these areas, preventing access where necessary
                                                                                                                      • identify persons who had incurred significant doses or were contaminated.

                                                                                                                             

                                                                                                                            The medical team initially:

                                                                                                                              • upon its arrival in Goiânia, took histories and triaged according to acute radiation syndrome symptoms
                                                                                                                              • sent all acute radiation patients to Goiânia Hospital (which was set up in advance for contamination and exposure control)
                                                                                                                              • transferred by air the next day the six most critical patients to the tertiary care center at a naval hospital in Rio de Janeiro (later eight more patients were transferred to this hospital)
                                                                                                                              • made arrangements for cytogenetic radiation dosimetry
                                                                                                                              • based medical management on each patient on that patient’s clinical course
                                                                                                                              • gave informal instruction to clinical laboratory staff to diminish their fears (the Goiânia medical community was reluctant to help).

                                                                                                                                         

                                                                                                                                        Health physicists:

                                                                                                                                          • assisted physicians in radiation dosimetry, bioassay and skin decontamination
                                                                                                                                          • coordinated and interpreted analysis of 4,000 urine and faecal samples in a four-month period
                                                                                                                                          • whole-body counted 600 individuals
                                                                                                                                          • coordinated radio-contamination monitoring of 112,000 individuals (249 were contaminated)
                                                                                                                                          • performed aerial survey of entire city and suburbs utilizing hastily assembled NaI detectors
                                                                                                                                          • performed auto-mounted NaI detector surveys of over 2,000 km of roads
                                                                                                                                          • set up action levels for decontamination of people, buildings, autos, soil and so on
                                                                                                                                          • coordinated 550 workers employed in decontamination efforts
                                                                                                                                          • coordinated demolition of seven houses and decontamination of 85 houses
                                                                                                                                          • coordinated hauling of 275 truckloads of contaminated waste
                                                                                                                                          • coordinated decontamination of 50 vehicles
                                                                                                                                          • coordinated packaging of 3,500 cubic metres of contaminated waste
                                                                                                                                          • utilized 55 survey meters, 23 contamination monitors and 450 self-reading dosimeters.

                                                                                                                                                                   

                                                                                                                                                                  Results

                                                                                                                                                                  Acute radiation syndrome patients

                                                                                                                                                                  Four patients died as a result of absorbed doses ranging from 4 to 6 Gy. Two patients exhibited severe bone marrow depression, but lived in spite of absorbed doses of 6.2 and 7.1 Gy (cytogenetic estimate). Four patients survived with estimated absorbed doses from 2.5 to 4 Gy.

                                                                                                                                                                  Radiation-induced skin injury

                                                                                                                                                                  Nineteen of twenty hospitalized patients had radiation-induced skin injuries, which started with swelling and blistering. These lesions later ruptured and secreted fluid. Ten of the nineteen skin injuries developed deep lesions about four to five weeks after irradiation. These deep lesions were indicative of significant gamma exposure of deeper tissues.

                                                                                                                                                                  All skin lesions were contaminated with 137Cs, with absorbed dose rates up to 15 mGy/h.

                                                                                                                                                                  The six-year-old girl who ingested 1 TBq of 137Cs (and who died one month later) had generalized skin contamination that averaged 3 mGy/h.

                                                                                                                                                                  One patient required an amputation about a month after exposure. Blood-pool imaging was useful in determining the demarcation between injured and normal arterioles.

                                                                                                                                                                  Internal contamination result

                                                                                                                                                                  Statistical tests showed no significant differences between body burdens determined by whole body counting as opposed to those determined by urinary excretion data.

                                                                                                                                                                  Models that related bioassay data with intakes and body burden were validated. These models were also applicable for different age groups.

                                                                                                                                                                  Prussian Blue was useful in promoting the elimination of 137CsCl from the body (if dosage was greater than 3 Gy/d).

                                                                                                                                                                  Seventeen patients received diuretics for the elimination of 137CsCl body burdens. These diuretics were ineffective in de-corporating 137Cs and their use was stopped.

                                                                                                                                                                  Skin decontamination

                                                                                                                                                                  Skin decontamination using soap and water, acetic acid, and titanium dioxide (TiO2) was performed on all patients. This decontamination was only partly successful. It was surmised that sweating resulted in recontaminating the skin from the 137Cs body burden.

                                                                                                                                                                  Contaminated skin lesions are very difficult to decontaminate. Sloughing of necrotic skin significantly reduced contamination levels.

                                                                                                                                                                  Follow-up study on cytogenetic analysis dose assessment

                                                                                                                                                                  Frequency of aberrations in lymphocytes at different times after the accident followed three main patterns:

                                                                                                                                                                  In two cases the frequencies of incidence of aberrations remained constant up to one month after the accident and declined to about 30% of the initial frequency three months later.

                                                                                                                                                                  In two cases a gradual decrease of about 20% every three months was found.

                                                                                                                                                                  In two of the cases of highest internal contamination there were increases in the frequency of incidence of aberrations (by about 50% and 100%) over a three-month period.

                                                                                                                                                                  Follow-up studies on 137Cs body burdens

                                                                                                                                                                    • Patients’ actual committed doses followed by bioassay.
                                                                                                                                                                    • Effects of Prussian Blue administration followed.
                                                                                                                                                                    • In vivo measurements for 20 people made on blood samples, wounds and organs to look for non-homogenous distribution of 137Cs and its retention in body tissues.
                                                                                                                                                                    • A woman and her newborn baby studied to look for retention and transfer by nursing.

                                                                                                                                                                           

                                                                                                                                                                          Action levels for intervention

                                                                                                                                                                          House evacuation was recommended for absorbed dose rates greater than 10 μGy/h at 1 m height inside the house.

                                                                                                                                                                          Remedial decontamination of property, clothing, soil and food was based on a person not exceeding 5 mGy in a year. Applying this criterion for different pathways resulted in decontaminating the inside of a house if the absorbed dose could exceed 1 mGy in a year and decontaminating soil if the absorbed dose rate could exceed 4 mGy in a year (3 mGy from external radiation and 1 mGy from internal radiation).

                                                                                                                                                                          The Chernobyl Nuclear Power Reactor Unit 4 Accident of 1986

                                                                                                                                                                          General description of the accident

                                                                                                                                                                          The world’s worst nuclear power reactor accident occurred on 26 April 1986 during a very low-powered electrical engineering test. In order to perform this test, a number of safety systems were switched off or blocked.

                                                                                                                                                                          This unit was a model RBMK-1000, the type of reactor that produced about 65% of all nuclear power generated in the USSR. It was a graphite-moderated, boiling-water reactor that generated 1,000 MW of electricity (MWe). The RBMK-1000 does not have a pressure-tested containment building and is not commonly built in most countries.

                                                                                                                                                                          The reactor went prompt critical and produced a series of steam explosions. The explosions blew off the entire top of the reactor, destroyed the thin structure covering the reactor, and started a series of fires on the thick asphalt roofs of units 3 and 4. Radioactive releases lasted for ten days, and 31 people died. The USSR delegation to the International Atomic Energy Agency studied the accident. They stated that the Chernobyl Unit 4 RBMK experiments that caused the accident had not received required approval and that the written rules on reactor safety measures were inadequate. The delegation further stated, “The staff involved were not adequately prepared for the tests and were not aware of the possible dangers.” This series of tests created the conditions for the emergency situation and led to a reactor accident which most believed could never occur.

                                                                                                                                                                          Release of Chernobyl Unit 4 accident fission products

                                                                                                                                                                          Total activity released

                                                                                                                                                                          Roughly 1,900 PBq of fission products and fuel (which together were labelled corium by the Three Mile Island Accident Recovery Team) were released over the ten days that it took to put out all the fires and seal off Unit 4 with a neutron absorbing shielding material. Unit 4 is now a permanently sealed steel and concrete sarcophagus that properly contains the residual corium in and around the remains of the destroyed reactor core.

                                                                                                                                                                          Twenty-five per cent of the 1,900 PBq was released on the first day of the accident. The rest was released during the next nine days.

                                                                                                                                                                          The most radiologically significant releases were 270 PBq of 131I, 8.1 PBq of 90Sr and 37 PBq of 137Cs. This can be compared with the Three Mile Island accident, which released 7.4 TBq of 131I and no measurable 90Sr or 137Cs.

                                                                                                                                                                          Environmental dispersion of radioactive materials

                                                                                                                                                                          The first releases went in a generally northern direction, but subsequent releases went toward the westerly and southwesterly directions. The first plume arrived in Sweden and Finland on 27 April. Nuclear power plant radiological environmental monitoring programmes immediately discovered the release and alerted the world about the accident. Part of this first plume drifted into Poland and East Germany. Subsequent plumes swept into eastern and central Europe on 29 and 30 April. After this, the United Kingdom saw Chernobyl releases on 2 May, followed by Japan and China on 4 May, India on 5 May and Canada and the US on 5 and 6 May. The southern hemisphere did not report detecting this plume.

                                                                                                                                                                          The deposition of the plume was governed mostly by precipitation. The fallout pattern of the major radionuclides (131I, 137Cs, 134Cs, and 90Sr) was highly variable, even within the USSR. The major risk came from external irradiation from surface deposition, as well as from ingestion of contaminated food.

                                                                                                                                                                          Radiological consequences of the Chernobyl Unit 4 accident

                                                                                                                                                                          General acute health consequences

                                                                                                                                                                          Two persons died immediately, one during the building collapse and one 5.5 hours later from thermal burns. An additional 28 of the reactor’s staff and fire-fighting crew died from radiation injuries. Radiation doses to the offsite population were below levels that can cause immediate radiation effects.

                                                                                                                                                                          The Chernobyl accident almost doubled the worldwide total of deaths due to radiation accidents through 1986 (from 32 to 61). (It is interesting to note that the three dead from the SL-1 reactor accident in the US are listed as due to a steam explosion and that the first two to die at Chernobyl are also not listed as radiation accident deaths.)

                                                                                                                                                                          Factors which influenced onsite health consequences of the accident

                                                                                                                                                                          Personnel dosimetry for the onsite persons at highest risk was not available. The absence of nausea or vomiting for the first six hours after exposure reliably indicated those patients who had received less than potentially fatal absorbed doses. This also was a good indication of patients who did not require immediate medical attention because of radiation exposure. This information together with blood data (decrease in lymphocyte count) was more useful than personnel dosimetry data.

                                                                                                                                                                          Fire-fighters’ heavy protective garments (a porous canvas) allowed high specific activity fission products to contact bare skin. These beta doses caused severe skin burns and were a significant factor in many of the deaths. Fifty-six workers received severe skin burns. The burns were extremely difficult to treat and were a serious complicating element. They made it impossible to decontaminate the patients prior to transport to hospitals.

                                                                                                                                                                          There were no clinically significant internal radioactive material body burdens at this time. Only two people had high (but not clinically significant) body burdens.

                                                                                                                                                                          Of the about 1,000 people screened, 115 were hospitalized due to acute radiation syndrome. Eight medical attendants working onsite incurred the acute radiation syndrome.

                                                                                                                                                                          As expected, there was no evidence of neutron exposure. (The test looks for sodium-24 (24Na) in blood.)

                                                                                                                                                                          Factors which influenced offsite health consequences of the accident

                                                                                                                                                                          Public protective actions can be divided into four distinct periods.

                                                                                                                                                                            1. The first 24 h: The downwind public remained indoors with doors and windows shut. Distribution of potassium iodide (KI) began in order to block thyroid uptake of 131I.
                                                                                                                                                                            2. One to seven days: Pripyat was evacuated after safe evacuation routes were established. Decontamination stations were established. The Kiev region was evacuated. The total number of people evacuated was more than 88,000.
                                                                                                                                                                            3. One to six weeks: The total number of evacuated people rose to 115,000. All these were medically examined and resettled. Potassium iodide was administered to 5.4 million Russians, including 1.7 million children. Thyroid doses were reduced by about 80 to 90%. Tens of thousands of cattle were removed from contaminated areas. Local milk and foodstuffs were banned over a large area (as dictated by derived intervention levels).
                                                                                                                                                                            4. After 6 weeks: The 30 km radius circle of evacuation was divided into three sub-zones: (a) a zone of 4 to 5 km where no public re-entry is expected in the foreseeable future, (b) a 5 to 10 km zone where limited public re-entry will be allowed after a specific time and (c) a 10 to 30 km zone where the public will eventually be allowed to return.

                                                                                                                                                                                   

                                                                                                                                                                                  A great effort has been expended in decontaminating offsite areas.

                                                                                                                                                                                  The total radiological dose to the USSR population was reported by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) to be 226,000 person-Sv (72,000 person-Sv committed during the first year). The worldwide estimated collective dose equivalent is on the order of 600,000 person-Sv. Time and further study will refine this estimate (UNSCEAR 1988).


                                                                                                                                                                                  International Organizations

                                                                                                                                                                                   

                                                                                                                                                                                  International Atomic Energy Agency

                                                                                                                                                                                  P.O. Box 100

                                                                                                                                                                                  A-1400 Vienna

                                                                                                                                                                                  AUSTRIA

                                                                                                                                                                                   

                                                                                                                                                                                  International Commission on Radiation Units and Measurements

                                                                                                                                                                                  7910 Woodmont Avenue

                                                                                                                                                                                  Bethesda, Maryland 20814

                                                                                                                                                                                  U.S.A.

                                                                                                                                                                                   

                                                                                                                                                                                  International Commission on Radiological Protection

                                                                                                                                                                                  P.O. Box No. 35

                                                                                                                                                                                  Didcot, Oxfordshire

                                                                                                                                                                                  OX11 0RJ

                                                                                                                                                                                  U.K.

                                                                                                                                                                                   

                                                                                                                                                                                  International Radiation Protection Association

                                                                                                                                                                                  Eindhoven University of Technology

                                                                                                                                                                                  P.O. Box 662

                                                                                                                                                                                  5600 AR Eindhoven

                                                                                                                                                                                  NETHERLANDS

                                                                                                                                                                                   

                                                                                                                                                                                  United Nations Committee on the Effects of Atomic Radiation

                                                                                                                                                                                  BERNAM ASSOCIATES

                                                                                                                                                                                  4611-F Assembly Drive

                                                                                                                                                                                  Lanham, Maryland 20706-4391

                                                                                                                                                                                  U.S.A.


                                                                                                                                                                                   

                                                                                                                                                                                   

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 20:03

                                                                                                                                                                                  Radiation Safety

                                                                                                                                                                                  This article describes aspects of radiation safety programmes. The objective of radiation safety is to eliminate or minimize harmful effects of ionizing radiation and radioactive material on workers, the public and the environment while allowing their beneficial uses.

                                                                                                                                                                                  Most radiation safety programmes will not have to implement every one of the elements described below. The design of a radiation safety programme depends on the types of ionizing radiation sources involved and how they are used.

                                                                                                                                                                                  Radiation Safety Principles

                                                                                                                                                                                  The International Commission on Radiological Protection (ICRP) has proposed that the following principles should guide the use of ionizing radiation and the application of radiation safety standards:

                                                                                                                                                                                  1. No practice involving exposures to radiation should be adopted unless it produces sufficient benefit to the exposed individuals or to society to offset the radiation detriment it causes (the justification of a practice).
                                                                                                                                                                                  2. In relation to any particular source within a practice, the magnitude of individual doses, the number of people exposed, and the likelihood of incurring exposures where these are not certain to be received should all be kept as low as reasonably achievable (ALARA), economic and social factors being taken into account. This procedure should be constrained by restrictions on the doses to individuals (dose constraints), so as to limit the inequity likely to result from the inherent economic and social judgements (the optimization of protection).
                                                                                                                                                                                  3. The exposure of individuals resulting from the combination of all the relevant practices should be subject to dose limits, or to some control of risk in the case of potential exposures. These are aimed at ensuring that no individual is exposed to radiation risks that are judged to be unacceptable from these practices in any normal circumstances. Not all sources are susceptible of control by action at the source and it is necessary to specify the sources to be included as relevant before selecting a dose limit (individual dose and risk limits).

                                                                                                                                                                                   

                                                                                                                                                                                  Radiation Safety Standards

                                                                                                                                                                                  Standards exist for radiation exposure of workers and the general public and for annual limits on intake (ALI) of radionuclides. Standards for concentrations of radionuclides in air and in water can be derived from the ALIs.

                                                                                                                                                                                  The ICRP has published extensive tabulations of ALIs and derived air and water concentrations. A summary of its recommended dose limits is in table 1.

                                                                                                                                                                                  Table 1. Recommended dose limits of the International Commission on Radiological Protection1

                                                                                                                                                                                  Application

                                                                                                                                                                                  Dose limit

                                                                                                                                                                                   
                                                                                                                                                                                   

                                                                                                                                                                                  Occupational

                                                                                                                                                                                  Public

                                                                                                                                                                                  Effective dose

                                                                                                                                                                                  20 mSv per year averaged over
                                                                                                                                                                                  defined periods of 5 years2

                                                                                                                                                                                  1 mSv in a year3

                                                                                                                                                                                  Annual equivalent dose in:

                                                                                                                                                                                  Lens of the eye

                                                                                                                                                                                  150 mSv

                                                                                                                                                                                  15 mSv

                                                                                                                                                                                  Skin4

                                                                                                                                                                                  500 mSv

                                                                                                                                                                                  50 mSv

                                                                                                                                                                                  Hands and feet

                                                                                                                                                                                  500 mSv

                                                                                                                                                                                  -

                                                                                                                                                                                  1 The limits apply to the sum of the relevant doses from external exposure in the specified period and the 50-year committed dose (to age 70 years for children) from intakes in the same period.

                                                                                                                                                                                  2 With the further provision that the effective dose should not exceed 50 mSv in any single year. Additional restrictions apply to the occupational exposure of pregnant women.

                                                                                                                                                                                  3 In special circumstances, a higher value of effective dose could be allowed in a single year, provided that the average over 5 years does not exceed 1 mSv per year.

                                                                                                                                                                                  4 The limitation on the effective dose provides sufficient protection for the skin against stochastic effects. An additional limit is needed for localized exposures in order to prevent deterministic effects.

                                                                                                                                                                                  Dosimetry

                                                                                                                                                                                  Dosimetry is used to indicate dose equivalents that workers receive from external radiation fields to which they may be exposed. Dosimeters are characterized by the type of device, the type of radiation they measure and the portion of the body for which the absorbed dose is to be indicated.

                                                                                                                                                                                  Three main types of dosimeters are most commonly employed. They are thermoluminescent dosimeters, film dosimeters and ionization chambers. Other types of dosimeters (not discussed here) include fission foils, track-etch devices and plastic “bubble” dosimeters.

                                                                                                                                                                                  Thermoluminescent dosimeters are the most commonly used type of personnel dosimeter. They take advantage of the principle that when some materials absorb energy from ionizing radiation, they store it such that later it can be recovered in the form of light when the materials are heated. To a high degree, the amount of light released is directly proportional to the energy absorbed from the ionizing radiation and hence to the absorbed dose the material received. This proportionality is valid over a very wide range of ionizing radiation energy and absorbed dose rates.

                                                                                                                                                                                  Special equipment is necessary to process thermoluminescent dosimeters accurately. Reading the thermoluminescent dosimeter destroys the dose information contained in it. However, after appropriate processing, thermoluminescent dosimeters are reusable.

                                                                                                                                                                                  The material used for thermoluminescent dosimeters must be transparent to the light it emits. The most common materials used for thermoluminescent dosimeters are lithium fluoride (LiF) and calcium fluoride (CaF2). The materials may be doped with other materials or made with a specific isotopic composition for specialized purposes such as neutron dosimetry.

                                                                                                                                                                                  Many dosimeters contain several thermoluminescent chips with different filters in front of them to allow discrimination between energies and types of radiation.

                                                                                                                                                                                  Film was the most popular material for personnel dosimetry before thermoluminescent dosimetry became common. The degree of film darkening depends on the energy absorbed from the ionizing radiation, but the relationship is not linear. Dependence of film response on total absorbed dose, absorbed dose rate and radiation energy is greater than that for thermoluminescent dosimeters and can limit film’s range of applicability. However, film has the advantage of providing a permanent record of the absorbed dose to which it was exposed.

                                                                                                                                                                                  Various film formulations and filter arrangements may be used for special purposes, such as neutron dosimetry. As with thermoluminescent dosimeters, special equipment is needed for proper analysis.

                                                                                                                                                                                  Film is generally much more sensitive to ambient humidity and temperature than thermoluminescent materials, and can give falsely high readings under adverse conditions. On the other hand, dose equivalents indicated by thermoluminescent dosimeters may be affected by the shock of dropping them on a hard surface.

                                                                                                                                                                                  Only the largest of organizations operate their own dosimetry services. Most obtain such services from companies specializing in providing them. It is important that such companies be licensed or accredited by appropriate independent authorities so that accurate dosimetry results are assured.

                                                                                                                                                                                  Self-reading, small ionization chambers, also called pocket chambers, are used to obtain immediate dosimetry information. Their use is often required when personnel must enter high or very high radiation areas, where personnel could receive a large absorbed dose in a short period of time. Pocket chambers often are calibrated locally, and they are very sensitive to shock. Consequently, they should always be supplemented by thermoluminescent or film dosimeters, which are more accurate and dependable but do not provide immediate results.

                                                                                                                                                                                  Dosimetry is required for a worker when he or she has a reasonable probability of accumulating a certain percentage, usually 5 or 10%, of the maximum permissible dose equivalent for the whole-body or certain parts of the body.

                                                                                                                                                                                  A whole-body dosimeter should be worn somewhere between the shoulders and the waist, at a point where the highest exposure is anticipated. When conditions of exposure warrant, other dosimeters may be worn on fingers or wrists, at the abdomen, on a band or hat at the forehead, or on a collar, to assess localized exposure to extremities, a foetus or embryo, the thyroid or the lenses of the eyes. Refer to appropriate regulatory guidelines about whether dosimeters should be worn inside or outside protective garments such as lead aprons, gloves and collars.

                                                                                                                                                                                  Personnel dosimeters indicate only the radiation to which the dosimeter was exposed. Assigning the dosimeter dose equivalent to the person or organs of the person is acceptable for small, trivial doses, but large dosimeter doses, especially those greatly exceeding regulatory standards, should be analysed carefully with respect to dosimeter placement and the actual radiation fields to which the worker was exposed when estimating the dose that the worker actually received. A statement should be obtained from the worker as part of the investigation and included in the record. However, much more often than not, very large dosimeter doses are the result of deliberate radiation exposure of the dosimeter while it was not being worn.

                                                                                                                                                                                  Bioassay

                                                                                                                                                                                  Bioassay (also called radiobioassay) means the determination of kinds, quantities or concentrations, and, in some cases, the locations of radioactive material in the human body, whether by direct measurement (in vivo counting) or by analysis and evaluation of materials excreted or removed from the human body.

                                                                                                                                                                                  Bioassay is usually used to assess worker dose equivalent due to radioactive material taken into the body. It also can provide an indication of the effectiveness of active measures taken to prevent such intake. More rarely it may be used to estimate the dose a worker received from a massive external radiation exposure (for example, by counting white blood cells or chromosomal defects).

                                                                                                                                                                                  Bioassay must be performed when a reasonable possibility exists that a worker may take or has taken into his or her body more than a certain percentage (usually 5 or 10%) of the ALI for a radionuclide. The chemical and physical form of the radionuclide sought in the body determines the type of bioassay necessary to detect it.

                                                                                                                                                                                  Bioassay can consist of analysing samples taken from the body (for example, urine, faeces, blood or hair) for radioactive isotopes. In this case, the amount of radioactivity in the sample can be related to the radioactivity in the person’s body and subsequently to the radiation dose that the person’s body or certain organs have received or are committed to receive. Urine bioassay for tritium is an example of this type of bioassay.

                                                                                                                                                                                  Whole or partial body scanning can be used to detect radionuclides that emit x or gamma rays of energy reasonably detectable outside the body. Thyroid bioassay for iodine-131 (131I) is an example of this type of bioassay.

                                                                                                                                                                                  Bioassay can be performed in-house or samples or personnel can be sent to a facility or organization that specializes in the bioassay to be performed. In either case, proper calibration of equipment and accreditation of laboratory procedures is essential to ensure accurate, precise, and defensible bioassay results.

                                                                                                                                                                                  Protective Clothing

                                                                                                                                                                                  Protective clothing is supplied by the employer to the worker to reduce the possibility of radioactive contamination of the worker or his or her clothing or to partially shield the worker from beta, x, or gamma radiation. Examples of the former are anti-contamination clothing, gloves, hoods and boots. Examples of the latter are leaded aprons, gloves and eyeglasses.

                                                                                                                                                                                  Respiratory Protection

                                                                                                                                                                                  A respiratory protection device is an apparatus, such as a respirator, used to reduce a worker’s intake of airborne radioactive materials.

                                                                                                                                                                                  Employers must use, to the extent practical, process or other engineering controls (for example, containment or ventilation) to limit the concentrations of the radioactive materials in air. When this is not possible for controlling the concentrations of radioactive material in air to values below those that define an airborne radioactivity area, the employer, consistent with maintaining the total effective dose equivalent ALARA, must increase monitoring and limit intakes by one or more of the following means:

                                                                                                                                                                                  • control of access
                                                                                                                                                                                  • limitation of exposure times
                                                                                                                                                                                  • use of respiratory protection equipment
                                                                                                                                                                                  • other controls.

                                                                                                                                                                                   

                                                                                                                                                                                  Respiratory protection equipment issued to workers must comply with applicable national standards for such equipment.

                                                                                                                                                                                  The employer must implement and maintain a respiratory protection programme that includes:

                                                                                                                                                                                  • air sampling sufficient to identify the potential hazard, permit proper equipment selection and estimate exposures
                                                                                                                                                                                  • surveys and bioassays, as appropriate, to evaluate actual intakes
                                                                                                                                                                                  • testing of respirators for operability immediately prior to each use
                                                                                                                                                                                  • written procedures regarding selection, fitting, issuance, maintenance and testing of respirators, including testing for operability immediately prior to each use; supervision and training of personnel; monitoring, including air sampling and bioassays; and record-keeping
                                                                                                                                                                                  • determination by a physician prior to the initial fitting of respirators, and periodically at a frequency determined by a physician, that the individual user is medically fit to use the respiratory protection equipment.

                                                                                                                                                                                   

                                                                                                                                                                                  The employer must advise each respirator user that the user may leave the work area at any time for relief from respirator use in the event of equipment malfunction, physical or psychological distress, procedural or communication failure, significant deterioration of operating conditions, or any other conditions that might require such relief.

                                                                                                                                                                                  Even though circumstances may not require routine use of respirators, credible emergency conditions may mandate their availability. In such cases, the respirators also must be certified for such use by an appropriate accrediting organization and maintained in a condition ready for use.

                                                                                                                                                                                  Occupational Health Surveillance

                                                                                                                                                                                  Workers exposed to ionizing radiation should receive occupational health services to the same extent as workers exposed to other occupational hazards.

                                                                                                                                                                                  General preplacement examinations assess the overall health of the prospective employee and establish baseline data. Previous medical and exposure history should always be obtained. Specialized examinations, such as of lens of the eye and blood cell counts, may be necessary depending on the nature of the expected radiation exposure. This should be left to the discretion of the attending physician.

                                                                                                                                                                                  Contamination Surveys

                                                                                                                                                                                  A contamination survey is an evaluation of the radiological conditions incident to the production, use, release, disposal or presence of radioactive materials or other sources of radiation. When appropriate, such an evaluation includes a physical survey of the location of radioactive material and measurements or calculations of levels of radiation, or concentrations or quantities of radioactive material present.

                                                                                                                                                                                  Contamination surveys are performed to demonstrate compliance with national regulations and to evaluate the extent of radiation levels, concentrations or quantities of radioactive material, and the potential radiological hazards that could be present.

                                                                                                                                                                                  The frequency of contamination surveys is determined by the degree of potential hazard present. Weekly surveys should be performed in radioactive waste storage areas and in laboratories and clinics where relatively large amounts of unsealed radioactive sources are used. Monthly surveys suffice for laboratories that work with small amounts of radioactive sources, such as laboratories that perform in vitro testing using isotopes such as tritium, carbon-14 (14C), and iodine-125 (125I) with activities less than a few kBq.

                                                                                                                                                                                  Radiation safety equipment and survey meters must be appropriate for the types of radioactive material and radiations involved, and must be properly calibrated.

                                                                                                                                                                                  Contamination surveys consist of measurements of ambient radiation levels with a Geiger-Mueller (G-M) counter, ionization chamber or scintillation counter; measurements of possible α or βγ surface contamination with appropriate thin-window G-M or zinc sulphide (ZnS) scintillation counters; and wipe tests of surfaces to be later counted in a scintillation (sodium iodide (NaI)) well counter, a germanium (Ge) counter or a liquid scintillation counter, as appropriate.

                                                                                                                                                                                  Appropriate action levels must be established for ambient radiation and contamination measurement results. When an action level is exceeded, steps must be taken immediately to mitigate the detected levels, restore them to acceptable conditions and prevent unnecessary personnel exposure to radiation and the uptake and spread of radioactive material.

                                                                                                                                                                                  Environmental Monitoring

                                                                                                                                                                                  Environmental monitoring refers to collecting and measuring environmental samples for radioactive materials and monitoring areas outside the environs of the workplace for radiation levels. Purposes of environmental monitoring include estimating consequences to humans resulting from the release of radionuclides to the biosphere, detecting releases of radioactive material to the environment before they become serious and demonstrating compliance with regulations.

                                                                                                                                                                                  A complete description of environmental monitoring techniques is beyond the scope of this article. However, general principles will be discussed.

                                                                                                                                                                                  Environmental samples must be taken that monitor the most likely pathway for radionuclides from the environment to man. For example, soil, water, grass and milk samples in agricultural regions around a nuclear power plant should be taken routinely and analysed for iodine-131 (131I) and strontium-90 (90Sr) content.

                                                                                                                                                                                  Environmental monitoring can include taking samples of air, ground water, surface water, soil, foliage, fish, milk, game animals and so on. The choices of which samples to take and how often to take them should be based on the purposes of the monitoring, although a small number of random samples may sometimes identify a previously unknown problem.

                                                                                                                                                                                  The first step in designing an environmental monitoring programme is to characterize the radionuclides being released or having the potential for being accidentally released, with respect to type and quantity and physical and chemical form.

                                                                                                                                                                                  The possibility of transport of these radionuclides through the air, ground water and surface water is the next consideration. The objective is to predict the concentrations of radionuclides reaching humans directly through air and water or indirectly through food.

                                                                                                                                                                                  The bioaccumulation of radionuclides resulting from deposition in aquatic and terrestrial environments is the next item of concern. The goal is to predict the concentration of radionuclides once they enter the food chain.

                                                                                                                                                                                  Finally, the rate of human consumption of these potentially contaminated foodstuffs and how this consumption contributes to human radiation dose and resultant health risk are examined. The results of this analysis are used to determine the best approach to environmental sampling and to ensure that the goals of the environmental monitoring programme are met.

                                                                                                                                                                                  Leak Tests of Sealed Sources

                                                                                                                                                                                  A sealed source means radioactive material that is encased in a capsule designed to prevent leakage or escape of the material. Such sources must be tested periodically to verify that the source is not leaking radioactive material.

                                                                                                                                                                                  Each sealed source must be tested for leakage before its first use unless the supplier has provided a certificate indicating that the source was tested within six months (three months for α emitters) before transfer to the present owner. Each sealed source must be tested for leakage at least once every six months (three months for α emitters) or at an interval specified by the regulatory authority.

                                                                                                                                                                                  Generally, leak tests on the following sources are not required:

                                                                                                                                                                                  • sources containing only radioactive material with a half-life of less than 30 days
                                                                                                                                                                                  • sources containing only radioactive material as a gas
                                                                                                                                                                                  • sources containing 4 MBq or less of βγ-emitting material or 0.4 MBq or less of α-emitting material
                                                                                                                                                                                  • sources stored and not being used; however, each such source must be tested for leakage before any use or transfer unless it has been leakage-tested within six months before the date of use or transfer
                                                                                                                                                                                  • seeds of iridium-192 (192Ir) encased in nylon ribbon.

                                                                                                                                                                                   

                                                                                                                                                                                  A leak test is performed by taking a wipe sample from the sealed source or from the surfaces of the device in which the sealed source is mounted or stored on which radioactive contamination might be expected to accumulate or by washing the source in a small volume of detergent solution and treating the entire volume as the sample.

                                                                                                                                                                                  The sample should be measured so that the leakage test can detect the presence of at least 200 Bq of radioactive material on the sample.

                                                                                                                                                                                  Sealed radium sources require special leak test procedures to detect leaking radon (Rn) gas. For example, one procedure involves keeping the sealed source in a jar with cotton fibres for at least 24 hours. At the end of the period, the cotton fibres are analysed for the presence of Rn progeny.

                                                                                                                                                                                  A sealed source found to be leaking in excess of allowable limits must be removed from service. If the source is not repairable, it should be handled as radioactive waste. The regulatory authority may require that leaking sources be reported in case the leakage is a result of a manufacturing defect worthy of further investigation.

                                                                                                                                                                                  Inventory

                                                                                                                                                                                  Radiation safety personnel must maintain an up-to-date inventory of all radioactive material and other sources of ionizing radiation for which the employer is responsible. The organization’s procedures must ensure that radiation safety personnel are aware of the receipt, use, transfer and disposal of all such material and sources so that the inventory can be kept current. A physical inventory of all sealed sources should be done at least once every three months. The complete inventory of ionizing radiation sources should be verified during the annual audit of the radiation safety programme.

                                                                                                                                                                                  Posting of Areas

                                                                                                                                                                                  Figure 1 shows the international standard radiation symbol. This must appear prominently on all signs denoting areas controlled for the purposes of radiation safety and on container labels indicating the presence of radioactive materials.

                                                                                                                                                                                  Figure 1. Radiation symbol

                                                                                                                                                                                  ION050F1

                                                                                                                                                                                  Areas controlled for the purposes of radiation safety are often designated in terms of increasing dose rate levels. Such areas must be conspicuously posted with a sign or signs bearing the radiation symbol and the words “CAUTION, RADIATION AREA,” “CAUTION (or DANGER), HIGH RADIATION AREA,” or “GRAVE DANGER, VERY HIGH RADIATION AREA,” as appropriate.

                                                                                                                                                                                  1. A radiation area is an area, accessible to personnel, in which radiation levels could result in an individual receiving a dose equivalent in excess of 0.05 mSv in 1 h at 30 cm from the radiation source or from any surface that the radiation penetrates.
                                                                                                                                                                                  2. A high radiation area is an area, accessible to personnel, in which radiation levels could result in an individual receiving a dose equivalent in excess of 1 mSv in 1 h at 30 cm from the radiation source or from any surface that the radiation penetrates.
                                                                                                                                                                                  3. A very high radiation area is an area, accessible to personnel, in which radiation levels could result in an individual receiving an absorbed dose in excess of 5 Gy in 1 h at 1 m from a radiation source or from any surface that the radiation penetrates.

                                                                                                                                                                                  If an area or room contains a significant amount of radioactive material (as defined by the regulatory authority), the entrance to such area or room must be conspicuously posted with a sign bearing the radiation symbol and the words “CAUTION (or DANGER), RADIOACTIVE MATERIALS”.

                                                                                                                                                                                  An airborne radioactivity area is a room or area in which airborne radioactivity exceeds certain levels defined by the regulatory authority. Each airborne radioactivity area must be posted with a conspicuous sign or signs bearing the radiation symbol and the words “CAUTION, AIRBORNE RADIOACTIVITY AREA” or “DANGER, AIRBORNE RADIOACTIVITY AREA”.

                                                                                                                                                                                  Exceptions for these posting requirements may be granted for patients’ rooms in hospitals where such rooms are otherwise under adequate control. Areas or rooms in which the sources of radiation are to be located for periods of eight hours or less and are otherwise constantly attended under adequate control by qualified personnel need not be posted.

                                                                                                                                                                                  Access Control

                                                                                                                                                                                  The degree to which access to an area must be controlled is determined by the degree of the potential radiation hazard in the area.

                                                                                                                                                                                  Control of access to high radiation areas

                                                                                                                                                                                  Each entrance or access point to a high radiation area must have one or more of the following features:

                                                                                                                                                                                  • a control device that, upon entry into the area, causes the level of radiation to be reduced below that level at which an individual might receive a dose of 1 mSv in 1 h at 30 cm from the radiation source or from any surface that the radiation penetrates
                                                                                                                                                                                  • a control device that energizes a conspicuous visible or audible alarm signal so that the individual entering the high radiation area and the supervisor of the activity are made aware of the entry
                                                                                                                                                                                  • entryways that are locked, except during periods when access to the area is required, with positive control over each individual entry.

                                                                                                                                                                                   

                                                                                                                                                                                  In place of the controls required for a high radiation area, continuous direct or electronic surveillance that is capable of preventing unauthorized entry may be substituted.

                                                                                                                                                                                  The controls must be established in a way that does not prevent individuals from leaving the high radiation area.

                                                                                                                                                                                  Control of access to very high radiation areas

                                                                                                                                                                                  In addition to the requirements for a high radiation area, additional measures must be instituted to ensure that an individual is not able to gain unauthorized or inadvertent access to areas in which radiation levels could be encountered at 5 Gy or more in 1 h at 1 m from a radiation source or any surface through which the radiation penetrates.

                                                                                                                                                                                  Markings on Containers and Equipment

                                                                                                                                                                                  Each container of radioactive material above an amount determined by the regulatory authority must bear a durable, clearly visible label bearing the radiation symbol and the words “CAUTION, RADIOACTIVE MATERIAL” or “DANGER, RADIOACTIVE MATERIAL”. The label must also provide sufficient information - such as the radionuclide(s) present, an estimate of the quantity of radioactivity, the date for which the activity is estimated, radiation levels, kinds of materials and mass enrichment - to permit individuals handling or using the containers, or working in the vicinity of the containers, to take precautions to avoid or minimize exposures.

                                                                                                                                                                                  Prior to removal or disposal of empty uncontaminated containers to unrestricted areas, the radioactive material label must be removed or defaced, or it must be clearly indicated that the container no longer contains radioactive materials.

                                                                                                                                                                                  Containers need not be labelled if:

                                                                                                                                                                                  1. the containers are attended by an individual who takes the precautions necessary to prevent the exposure of individuals in excess of the regulatory limits
                                                                                                                                                                                  2. containers, when they are in transport, are packaged and labelled in accordance with appropriate transportation regulations
                                                                                                                                                                                  3. containers are accessible only to individuals authorized to handle or use them, or to work in the vicinity of the containers, if the contents are identified to these individuals by a readily available written record (examples of containers of this type are containers in locations such as water-filled canals, storage vaults or hot cells); the record must be retained as long as the containers are in use for the purpose indicated on the record; or
                                                                                                                                                                                  4. the containers are installed in manufacturing or process equipment, such as reactor components, piping and tanks.

                                                                                                                                                                                   

                                                                                                                                                                                  Warning Devices and Alarms

                                                                                                                                                                                  High radiation areas and very high radiation areas must be equipped with warning devices and alarms as discussed above. These devices and alarms can be visible or audible or both. Devices and alarms for systems such as particle accelerators should be automatically energized as part of the start-up procedure so that personnel will have time to vacate the area or turn off the system with a “scram” button before radiation is produced. “Scram” buttons (buttons in the controlled area that, when pressed, cause radiation levels to drop immediately to safe levels) must be easily accessible and prominently marked and displayed.

                                                                                                                                                                                  Monitor devices, such as continuous air monitors (CAMs), can be preset to emit audible and visible alarms or to turn off a system when certain action levels are exceeded.

                                                                                                                                                                                  Instrumentation

                                                                                                                                                                                  The employer must make available instrumentation appropriate for the degree and kinds of radiation and radioactive material present in the workplace. This instrumentation may be used to detect, monitor or measure the levels of radiation or radioactivity.

                                                                                                                                                                                  The instrumentation must be calibrated at appropriate intervals using accredited methods and calibration sources. The calibration sources should be as much as possible like the sources to be detected or measured.

                                                                                                                                                                                  Types of instrumentation include hand-held survey instruments, continuous air monitors, hand-and-feet portal monitors, liquid scintillation counters, detectors containing Ge or NaI crystals and so on.

                                                                                                                                                                                  Radioactive Material Transportation

                                                                                                                                                                                  The International Atomic Energy Agency (IAEA) has established regulations for the transportation of radioactive material. Most countries have adopted regulations compatible with IAEA radioactive shipment regulations.

                                                                                                                                                                                  Figure 2. Category I - WHITE label

                                                                                                                                                                                  ION050F2

                                                                                                                                                                                  Figure 2, figure 3 and figure 4 are examples of shipping labels that IAEA regulations require on the exterior of packages presented for shipment that contain radioactive materials. The transport index on the labels shown in figure 3 and figure 4 refer to the highest effective dose rate at 1 m from any surface of the package in mSv/h multiplied by 100, then rounded up to the nearest tenth. (For example, if the highest effective dose rate at 1 m from any surface of a package is 0.0233 mSv/h, then the transport index is 2.4.)

                                                                                                                                                                                  Figure 3. Category II - YELLOW label

                                                                                                                                                                                  ION050F3
                                                                                                                                                                                  Figure 4. Category III - YELLOW label
                                                                                                                                                                                  ION050F4

                                                                                                                                                                                   

                                                                                                                                                                                  Figure 5 shows an example of a placard that ground vehicles must prominently display when carrying packages containing radioactive materials above certain amounts.

                                                                                                                                                                                  Figure 5. Vehicle placard

                                                                                                                                                                                  ION050F5

                                                                                                                                                                                  Packaging intended for use in shipping radioactive materials must comply with stringent testing and documentation requirements. The type and quantity of radioactive material being shipped determines what specifications the packaging must meet.

                                                                                                                                                                                  Radioactive material transportation regulations are complicated. Persons who do not routinely ship radioactive materials should always consult experts experienced with such shipments.

                                                                                                                                                                                  Radioactive Waste

                                                                                                                                                                                  Various radioactive waste disposal methods are available, but all are controlled by regulatory authorities. Therefore, an organization must always confer with its regulatory authority to ensure that a disposal method is permissible. Radioactive waste disposal methods include holding the material for radioactive decay and subsequent disposal without regard to radioactivity, incineration, disposal in the sanitary sewerage system, land burial and burial at sea. Burial at sea is often not permitted by national policy or international treaty and will not be discussed further.

                                                                                                                                                                                  Radioactive waste from reactor cores (high-level radioactive waste) presents special problems with regard to disposal. Handling and disposal of such wastes is controlled by national and international regulatory authorities.

                                                                                                                                                                                  Often radioactive waste may have a property other than radioactivity that by itself would make the waste hazardous. Such wastes are called mixed wastes. Examples include radioactive waste that is also a biohazard or is toxic. Mixed wastes require special handling. Refer to regulatory authorities for proper disposition of such wastes.

                                                                                                                                                                                  Holding for radioactive decay

                                                                                                                                                                                  If the half-life of the radioactive material is short (generally less than 65 days) and if the organization has enough storage space, the radioactive waste can be held for decay with subsequent disposal without regard to its radioactivity. A holding period of at least ten half-lives usually is sufficient to make radiation levels indistinguishable from background.

                                                                                                                                                                                  The waste must be surveyed before it may be disposed of. The survey should employ instrumentation appropriate for the radiation to be detected and demonstrate that radiation levels are indistinguishable from background.

                                                                                                                                                                                  Incineration

                                                                                                                                                                                  If the regulatory authority allows incineration, then usually it must be demonstrated that such incineration does not cause the concentration of radionuclides in air to exceed permissible levels. The ash must be surveyed periodically to verify that it is not radioactive. In some circumstances it may be necessary to monitor the stack to ensure that permissible air concentrations are not being exceeded.

                                                                                                                                                                                  Disposal in the sanitary sewerage system

                                                                                                                                                                                  If the regulatory authority allows such disposal, then usually it must be demonstrated that such disposal does not cause the concentration of radionuclides in water to exceed permissible levels. Material to be disposed of must be soluble or otherwise readily dispersible in water. The regulatory authority often sets specific annual limits to such disposal by radionuclide.

                                                                                                                                                                                  Land burial

                                                                                                                                                                                  Radioactive waste not disposable by any other means will be disposed of by land burial at sites licensed by national or local regulatory authorities. Regulatory authorities control such disposal tightly. Waste generators usually are not allowed to dispose of radioactive waste on their own land. Costs associated with land burial include packaging, shipping and storage expenses. These costs are in addition to the cost of the burial space itself and can often be reduced by compacting the waste. Land burial costs for radioactive waste disposal are rapidly escalating.

                                                                                                                                                                                  Programme Audits

                                                                                                                                                                                  Radiation safety programmes should be audited periodically for effectiveness, completeness and compliance with regulatory authority. The audit should be done at least once a year and be comprehensive. Self-audits are usually permissible but audits by independent outside agencies are desirable. Outside agency audits tend to be more objective and have a more global point of view than local audits. An auditing agency not associated with day-to-day operations of a radiation safety programme often can identify problems not seen by the local operators, who may have become accustomed to overlooking them.

                                                                                                                                                                                  Training

                                                                                                                                                                                  Employers must provide radiation safety training to all workers exposed or potentially exposed to ionizing radiation or radioactive materials. They must provide initial training before a worker begins work and annual refresher training. In addition, each female worker of child-bearing age must be provided special training and information about the effects of ionizing radiation on the unborn child and about appropriate precautions she should take. This special training must be given when she is first employed, at annual refresher training, and if she notifies her employer that she is pregnant.

                                                                                                                                                                                  All individuals working in or frequenting any portion of an area access to which is restricted for the purposes of radiation safety:

                                                                                                                                                                                  • must be kept informed of the storage, transfer or use of radioactive materials or of radiation in such portions of the restricted area
                                                                                                                                                                                  • must be instructed in the health protection problems associated with exposure to such radioactive materials or radiation, in precautions or procedures to minimize exposure, and in the purposes and functions of protective devices employed
                                                                                                                                                                                  • must be instructed in, and instructed to observe, to the extent within the worker’s control, the applicable provisions of national and employer regulations for the protection of personnel from exposures to radiation or radioactive materials occurring in such areas
                                                                                                                                                                                  • must be instructed of their responsibility to report promptly to the employer any condition which may lead to or cause a violation of national or employer regulations or unnecessary exposure to radiation or to radioactive material
                                                                                                                                                                                  • must be instructed in the appropriate response to warnings made in the event of any unusual occurrence or malfunction that may involve exposure to radiation or radioactive material
                                                                                                                                                                                  • must be advised as to the radiation exposure reports that workers may request.

                                                                                                                                                                                   

                                                                                                                                                                                  The extent of radiation safety instructions must be commensurate with potential radiological health protection problems in the controlled area. Instructions must be extended as appropriate to ancillary personnel, such as nurses who attend radioactive patients in hospitals and fire-fighters and police officers who might respond to emergencies.

                                                                                                                                                                                  Worker Qualifications

                                                                                                                                                                                  Employers must ensure that workers using ionizing radiation are qualified to perform the work for which they are employed. The workers must have the background and experience to perform their jobs safely, particularly with reference to exposure to and use of ionizing radiation and radioactive materials.

                                                                                                                                                                                  Radiation safety personnel must have the appropriate knowledge and qualifications to implement and operate a good radiation safety programme. Their knowledge and qualifications must be at least commensurate with the potential radiological health protection problems that they and the workers are reasonably likely to encounter.

                                                                                                                                                                                  Emergency Planning

                                                                                                                                                                                  All but the smallest operations that use ionizing radiation or radioactive materials must have emergency plans in place. These plans must be kept current and exercised on a periodic basis.

                                                                                                                                                                                  Emergency plans should address all credible emergency situations. The plans for a large nuclear power plant will be much more extensive and involve a much larger area and number of people than the plans for a small radioisotope laboratory.

                                                                                                                                                                                  All hospitals, especially in large metropolitan areas, should have plans for receiving and caring for radioactively contaminated patients. Police and fire-fighting organizations should have plans for dealing with transportation accidents involving radioactive material.

                                                                                                                                                                                  Record Keeping

                                                                                                                                                                                  The radiation safety activities of an organization must be fully documented and appropriately retained. Such records are essential if the need arises for past radiation exposures or radioactivity releases and for demonstrating compliance with regulatory authority requirements. Consistent, accurate and comprehensive record keeping must receive high priority.

                                                                                                                                                                                  Organizational Considerations

                                                                                                                                                                                  The position of the person primarily responsible for radiation safety must be placed in the organization so that he or she has immediate access to all echelons of workers and management. He or she must have free access to areas to which access is restricted for purposes of radiation safety and the authority to halt unsafe or illegal practices immediately.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 19:45

                                                                                                                                                                                  Workplace Design for Radiation Safety

                                                                                                                                                                                  Basic Design Features of Radiation Facilities

                                                                                                                                                                                  Hazards associated with the handling and use of radiation sources necessitate special features of design and construction that are not required for conventional laboratories or working areas. These special design features are incorporated so that the facility worker is not unduly hampered while ensuring that he or she is not exposed to undue external or internal radiation hazards.

                                                                                                                                                                                  Access to all areas where exposure to radiation sources or radioactive materials could occur must be controlled not only with respect to the facility workers who may be permitted to enter such work areas, but also with respect to the type of clothing or protective equipment that they should wear and the precautions that they should take in controlled areas. In the administration of such control measures, it helps to classify radiation work areas based on the presence of ionizing radiation, on the presence of radioactive contamination or both. The introduction of such work area classification concepts in early planning stages will result in the facility having all the features necessary to make operations with radiation sources less hazardous.

                                                                                                                                                                                  Classification of working areas and laboratory types

                                                                                                                                                                                  The basis for the classification of the work area is the grouping of radionuclides according to their relative radiotoxicities per unit activity. Group I should be classified as very high toxicity radionuclides, Group II as moderate-to-high toxicity radionuclides, Group III as moderate toxicity radionuclides, and Group IV as low toxicity radionuclides. Table 1 shows the toxicity group classification of many radionuclides.

                                                                                                                                                                                  Table 1. Radionuclides classified according to relative radiotoxicity per unit activity

                                                                                                                                                                                  Group I: Very high toxicity

                                                                                                                                                                                  210Pb

                                                                                                                                                                                  210Po

                                                                                                                                                                                  223Ra

                                                                                                                                                                                  226Ra

                                                                                                                                                                                  228Ra

                                                                                                                                                                                  227Ac

                                                                                                                                                                                  227Th

                                                                                                                                                                                  228Th

                                                                                                                                                                                  230Th

                                                                                                                                                                                  231Pa

                                                                                                                                                                                  230U

                                                                                                                                                                                  232U

                                                                                                                                                                                  233U

                                                                                                                                                                                  234U

                                                                                                                                                                                  237Np

                                                                                                                                                                                  238Pu

                                                                                                                                                                                  239Pu

                                                                                                                                                                                  240Pu

                                                                                                                                                                                  241Pu

                                                                                                                                                                                  242Pu

                                                                                                                                                                                  241Am

                                                                                                                                                                                  243Am

                                                                                                                                                                                  242Cm

                                                                                                                                                                                  243Cm

                                                                                                                                                                                  244Cm

                                                                                                                                                                                  245Cm

                                                                                                                                                                                  246Cm

                                                                                                                                                                                  249Cm

                                                                                                                                                                                  250Cf

                                                                                                                                                                                  252Cf

                                                                                                                                                                                  Group II: High toxicity

                                                                                                                                                                                  22Na

                                                                                                                                                                                  36Cl

                                                                                                                                                                                  45Ca

                                                                                                                                                                                  46Sc

                                                                                                                                                                                  54Mn

                                                                                                                                                                                  56Co

                                                                                                                                                                                  60Co

                                                                                                                                                                                  89Sr

                                                                                                                                                                                  90Sr

                                                                                                                                                                                  91Y

                                                                                                                                                                                  95Zr

                                                                                                                                                                                  106Ru

                                                                                                                                                                                  110Agm

                                                                                                                                                                                  115Cdm

                                                                                                                                                                                  114Inm

                                                                                                                                                                                  124Sb

                                                                                                                                                                                  125Sb

                                                                                                                                                                                  127Tem

                                                                                                                                                                                  129Tem

                                                                                                                                                                                  124I

                                                                                                                                                                                  126I

                                                                                                                                                                                  131I

                                                                                                                                                                                  133I

                                                                                                                                                                                  134Cs

                                                                                                                                                                                  137Cs

                                                                                                                                                                                  140Ba

                                                                                                                                                                                  144Ce

                                                                                                                                                                                  152Eu (13 y)

                                                                                                                                                                                  154Eu

                                                                                                                                                                                  160Tb

                                                                                                                                                                                  170Tm

                                                                                                                                                                                  181Hf

                                                                                                                                                                                  210Bi

                                                                                                                                                                                  182Ta

                                                                                                                                                                                  192Ir

                                                                                                                                                                                  204Tl

                                                                                                                                                                                  207Bi

                                                                                                                                                                                  230Pa

                                                                                                                                                                                  211At

                                                                                                                                                                                  212Pb

                                                                                                                                                                                  224Ra

                                                                                                                                                                                  228Ac

                                                                                                                                                                                  234Th

                                                                                                                                                                                  236U

                                                                                                                                                                                  249Bk

                                                                                                                                                                                           

                                                                                                                                                                                  Group III: Moderate toxicity

                                                                                                                                                                                  7Be

                                                                                                                                                                                  14C

                                                                                                                                                                                  18F

                                                                                                                                                                                  24Na

                                                                                                                                                                                  38Cl

                                                                                                                                                                                  31Si

                                                                                                                                                                                  32P

                                                                                                                                                                                  35S

                                                                                                                                                                                  41A

                                                                                                                                                                                  42K

                                                                                                                                                                                  43K

                                                                                                                                                                                  47Sc

                                                                                                                                                                                  48Sc

                                                                                                                                                                                  48V

                                                                                                                                                                                  51Cr

                                                                                                                                                                                  52Mn

                                                                                                                                                                                  56Mn

                                                                                                                                                                                  52Fe

                                                                                                                                                                                  55Fe

                                                                                                                                                                                  59Fe

                                                                                                                                                                                  57Co

                                                                                                                                                                                  53Ni

                                                                                                                                                                                  65Ni

                                                                                                                                                                                  64Cu

                                                                                                                                                                                  65Zn

                                                                                                                                                                                  69Znm

                                                                                                                                                                                  72Ga

                                                                                                                                                                                  73As

                                                                                                                                                                                  74As

                                                                                                                                                                                  76As

                                                                                                                                                                                  77As

                                                                                                                                                                                  82Br

                                                                                                                                                                                  85Krm

                                                                                                                                                                                  87Kr

                                                                                                                                                                                  86Rb

                                                                                                                                                                                  85Sr

                                                                                                                                                                                  91Sr

                                                                                                                                                                                  90Y

                                                                                                                                                                                  92Y

                                                                                                                                                                                  93Y

                                                                                                                                                                                  97Zr

                                                                                                                                                                                  95Nb

                                                                                                                                                                                  99Mo

                                                                                                                                                                                  96Tc

                                                                                                                                                                                  97Tcm

                                                                                                                                                                                  97Tc

                                                                                                                                                                                  99Tc

                                                                                                                                                                                  97Ru

                                                                                                                                                                                  103Ru

                                                                                                                                                                                  105Ru

                                                                                                                                                                                  105Rh

                                                                                                                                                                                  109Pd

                                                                                                                                                                                  105Ag

                                                                                                                                                                                  111Ag

                                                                                                                                                                                  109Cd

                                                                                                                                                                                  115Cd

                                                                                                                                                                                  115Inm

                                                                                                                                                                                  113Sn

                                                                                                                                                                                  125Sn

                                                                                                                                                                                  122Sb

                                                                                                                                                                                  125Tem

                                                                                                                                                                                  129Te

                                                                                                                                                                                  131Tem

                                                                                                                                                                                  132Te

                                                                                                                                                                                  130I

                                                                                                                                                                                  132I

                                                                                                                                                                                  134I

                                                                                                                                                                                  135I

                                                                                                                                                                                  135Xe

                                                                                                                                                                                  131Cs

                                                                                                                                                                                  136Cs

                                                                                                                                                                                  140La

                                                                                                                                                                                  141Ce

                                                                                                                                                                                  143Ce

                                                                                                                                                                                  142Pr

                                                                                                                                                                                  143Pr

                                                                                                                                                                                  147Nd

                                                                                                                                                                                  149Nd

                                                                                                                                                                                  147Pm

                                                                                                                                                                                  149Pm

                                                                                                                                                                                  151Sm

                                                                                                                                                                                  152Eu (9.2 h)

                                                                                                                                                                                  155Eu

                                                                                                                                                                                  153Gd

                                                                                                                                                                                  159Gd

                                                                                                                                                                                  165Dy

                                                                                                                                                                                  166Dy

                                                                                                                                                                                  166Ho

                                                                                                                                                                                  169Er

                                                                                                                                                                                  171Er

                                                                                                                                                                                  171Tm

                                                                                                                                                                                  177Lu

                                                                                                                                                                                  181W

                                                                                                                                                                                  185W

                                                                                                                                                                                  187W

                                                                                                                                                                                  183Re

                                                                                                                                                                                  186Re

                                                                                                                                                                                  188Re

                                                                                                                                                                                  185Os

                                                                                                                                                                                  191Os

                                                                                                                                                                                  193Os

                                                                                                                                                                                  190Ir

                                                                                                                                                                                  195Ir

                                                                                                                                                                                  191Pt

                                                                                                                                                                                  193Pt

                                                                                                                                                                                  197Pt

                                                                                                                                                                                  196Au

                                                                                                                                                                                  198Au

                                                                                                                                                                                  199Au

                                                                                                                                                                                  197Hg

                                                                                                                                                                                  197Hgm

                                                                                                                                                                                  203Hg

                                                                                                                                                                                  200Tl

                                                                                                                                                                                  201Tl

                                                                                                                                                                                  202Tl

                                                                                                                                                                                  203Pb

                                                                                                                                                                                  206Bi

                                                                                                                                                                                  212Bi

                                                                                                                                                                                  220Rn

                                                                                                                                                                                  222Rn

                                                                                                                                                                                  231Th

                                                                                                                                                                                  233Pa

                                                                                                                                                                                  239Np

                                                                                                                                                                                               

                                                                                                                                                                                  Group IV: Low toxicity

                                                                                                                                                                                  3H

                                                                                                                                                                                  15O

                                                                                                                                                                                  37A

                                                                                                                                                                                  58Com

                                                                                                                                                                                  59Ni

                                                                                                                                                                                  69Zn

                                                                                                                                                                                  71Ge

                                                                                                                                                                                  85Kr

                                                                                                                                                                                  85Srm

                                                                                                                                                                                  87Rb

                                                                                                                                                                                  91Ym

                                                                                                                                                                                  93Zr

                                                                                                                                                                                  97Nb

                                                                                                                                                                                  96Tcm

                                                                                                                                                                                  99Tcm

                                                                                                                                                                                  103Rhm

                                                                                                                                                                                  133Inm

                                                                                                                                                                                  129I

                                                                                                                                                                                  131Xem

                                                                                                                                                                                  133Xe

                                                                                                                                                                                  134Csm

                                                                                                                                                                                  135Cs

                                                                                                                                                                                  147Sm

                                                                                                                                                                                  187Re

                                                                                                                                                                                  191Osm

                                                                                                                                                                                  193Ptm  

                                                                                                                                                                                  197Ptm

                                                                                                                                                                                  natTh

                                                                                                                                                                                  232Th

                                                                                                                                                                                  235U

                                                                                                                                                                                  238U

                                                                                                                                                                                  natU

                                                                                                                                                                                                 

                                                                                                                                                                                  (IAEA 1973)

                                                                                                                                                                                  Three broad types of laboratories can be envisaged on the basis of radiotoxicity considerations, the amounts or quantities of radioactive materials that will be handled in the work area and the type of operations involved.

                                                                                                                                                                                  Table 2 describes laboratories by type and provides examples for each type. Table 3 shows the types of laboratories along with the work area classification and access control (IAEA 1973).

                                                                                                                                                                                  Table 2. Classification of working areas

                                                                                                                                                                                  Type

                                                                                                                                                                                  Definition

                                                                                                                                                                                  Access control

                                                                                                                                                                                  Typical operations

                                                                                                                                                                                  1

                                                                                                                                                                                  Areas in which the external radiation absorbed dose levels or radioactive contamination levels could be high

                                                                                                                                                                                  Access controlled to radiation workers only, under strictly controlled working conditions and with appropriate protective equipment

                                                                                                                                                                                  Hot laboratories, highly contaminated areas

                                                                                                                                                                                  2

                                                                                                                                                                                  Areas in which external radiation levels could exist and in which the possibility of contamination necessitates operating instructions

                                                                                                                                                                                  Access limited to radiation workers with
                                                                                                                                                                                  appropriate protective clothing and footwear

                                                                                                                                                                                  Luminizing factories and other equivalent
                                                                                                                                                                                  facilities

                                                                                                                                                                                  3

                                                                                                                                                                                  Areas in which the average external radiation level is less than 1 mGy·wk-1 and in which the possibility of radioactive contamination necessitates special operating instructions

                                                                                                                                                                                  Access limited to radiation workers, no
                                                                                                                                                                                  protective clothing required

                                                                                                                                                                                  Working areas in the immediate vicinity of
                                                                                                                                                                                  radiographic operation, for example, control rooms

                                                                                                                                                                                  4

                                                                                                                                                                                  Areas within the confines of a radiation facility where the external radiation levels are less than 0.1 mGy•wk-1 and where
                                                                                                                                                                                  radioactive contamination is not present

                                                                                                                                                                                  Access uncontrolled

                                                                                                                                                                                  Administration and patient waiting areas

                                                                                                                                                                                  (ICRP 1977, IAEA 1973)

                                                                                                                                                                                  Table 3. Classification of laboratories for handling radioactive materials

                                                                                                                                                                                  Group of
                                                                                                                                                                                  radionuclides

                                                                                                                                                                                  Type of laboratory required for the activity specified below

                                                                                                                                                                                   

                                                                                                                                                                                  Type 1

                                                                                                                                                                                  Type 2

                                                                                                                                                                                  Type 3

                                                                                                                                                                                  I

                                                                                                                                                                                  <370 kBq

                                                                                                                                                                                  70 kBq to
                                                                                                                                                                                  37 MBq

                                                                                                                                                                                  >37 MBq

                                                                                                                                                                                  II

                                                                                                                                                                                  <37 MBq

                                                                                                                                                                                  37 MBq to
                                                                                                                                                                                  37 GBq

                                                                                                                                                                                  >37 GBq

                                                                                                                                                                                  III

                                                                                                                                                                                  <37 GBq

                                                                                                                                                                                  37 GBq to
                                                                                                                                                                                  370 GBq

                                                                                                                                                                                  >370 GBq

                                                                                                                                                                                  IV

                                                                                                                                                                                  <370 GBq

                                                                                                                                                                                  370 GBq to
                                                                                                                                                                                  37 TBq

                                                                                                                                                                                  >37 Tbq

                                                                                                                                                                                   

                                                                                                                                                                                  Operational factors for laboratory use of radioactive material

                                                                                                                                                                                  Multiplication factors for the activity levels

                                                                                                                                                                                  Simple storage

                                                                                                                                                                                  ×100

                                                                                                                                                                                  Simple wet operations (for example, preparation of aliquots of stock solution)

                                                                                                                                                                                  ×10

                                                                                                                                                                                  Normal chemical operations (for example, simple chemical preparation and analysis)

                                                                                                                                                                                  ×1

                                                                                                                                                                                  Complex wet operations (for example, multiple operations or operations with complex glass ware)

                                                                                                                                                                                  ×0.1

                                                                                                                                                                                  Simple dry operations (for example, manipulations of powders of volatile radioactive compounds)

                                                                                                                                                                                  ×0.1

                                                                                                                                                                                  Dry and dusty operations (for example, grinding)

                                                                                                                                                                                  ×0.01

                                                                                                                                                                                  (ICRP 1977, IAEA 1973)

                                                                                                                                                                                  The hazards involved in working with radioactive material depend not only on the level of radiotoxicity or chemical toxicity and the activity of the radionuclides, but also on the radioactive material’s physical and chemical form and on the nature and complexity of the operation or procedure being performed.

                                                                                                                                                                                  Location of a radiation facility in a building

                                                                                                                                                                                  When a radiation facility is part of a large building, the following should be kept in mind when deciding on the location of such a facility:

                                                                                                                                                                                  • The radiation facility should be located in a relatively unfrequented part of the building, so that access to the area can be easily controlled.
                                                                                                                                                                                  • The potential for fires should be minimal in the area chosen.
                                                                                                                                                                                  • The location of the radiation facility and the heating and ventilation provided should be such that possibilities for the spread of both surface and airborne radioactive contamination are minimal.
                                                                                                                                                                                  • The location of the radiation facility should be chosen judiciously, so that with a minimum expenditure for shielding, radiation levels can be effectively maintained within established limits in the immediate vicinity.

                                                                                                                                                                                   

                                                                                                                                                                                  Planning of radiation facilities

                                                                                                                                                                                  Where a gradation of levels of activity is envisioned, the laboratory should be located so that access to areas where high radiation or radioactive contamination levels exist is gradual; that is, one first enters a non-radiation area, then a low activity area, then a medium activity area and so on.

                                                                                                                                                                                  The need for elaborate control of ventilation in small laboratories can be avoided by the use of hoods or glove boxes for handling unsealed sources of radioactive material. However, the ventilation system should be designed to permit air flow in a direction such that any radioactive material that becomes airborne will flow away from the radiation worker. The air flow should always be from an uncontaminated area toward a contaminated or potentially contaminated area.

                                                                                                                                                                                  For the handling of unsealed sources of low to medium radioactivity, the average air speed through the opening in the hood must be about 0.5 ms–1. For highly radiotoxic or high-level radioactivity, the air velocity through the opening should be raised to an average of 0.6 to
                                                                                                                                                                                  1.0 ms–1. However, excessively high air speeds can draw out radioactive materials from open containers and contaminate the entire hood area.

                                                                                                                                                                                  The placement of the hood in the laboratory is important with respect to cross-drafts. In general, a hood should be located well away from doorways where supply or make-up air must enter. Dual-speed fans will permit operation at a higher air velocity while the hood is in use and a lower velocity when it is closed.

                                                                                                                                                                                  The aim of any ventilating system should be to:

                                                                                                                                                                                  • provide comfortable working conditions
                                                                                                                                                                                  • provide continuous air changes (three to five changes per hour) for the purposes of removing and diluting undesirable air contaminants
                                                                                                                                                                                  • minimize the contamination of other areas of the building and the environment.

                                                                                                                                                                                   

                                                                                                                                                                                  In the design of radiation facilities, heavy shielding requirements can be minimized by the adoption of certain simple measures. For example, for radiation therapy, accelerators, neutron generators or panoramic radiation sources, a maze can reduce the need for a heavy lead-lined door. Tapering of the primary protective barrier in areas that are not directly in the useful beam or locating the facility partially or completely underground can significantly reduce the amount of required shielding.

                                                                                                                                                                                  Careful attention must be paid to the proper positioning of viewing windows, underground conduit cables and ventilation system baffles. The viewing window should intercept scattered radiation only. Even better is a closed circuit television, which can also improve efficiency.

                                                                                                                                                                                  Surface finishes within a work area

                                                                                                                                                                                  All raw surfaces, such as plaster, concrete, wood and so on, should be permanently sealed with a suitable material. The choice of material should be made with the following considerations in mind:

                                                                                                                                                                                  • the provision of a smooth, chemically inert surface
                                                                                                                                                                                  • the environmental conditions of temperature, humidity and mechanical wear and tear to which the surfaces may be exposed
                                                                                                                                                                                  • compatibility with radiation fields to which the surface is exposed
                                                                                                                                                                                  • the need for ease of repair in the event of damage.

                                                                                                                                                                                   

                                                                                                                                                                                  Ordinary paints, varnishes and lacquers are not recommended for covering wear surfaces. The application of a surfacing material that can be easily removed may be helpful if contamination occurs and decontamination is required. However, the removal of such materials sometimes can be difficult and messy.

                                                                                                                                                                                  Plumbing

                                                                                                                                                                                  Sinks, wash basins and floor drains should be properly marked. Wash basins where contaminated hands may be washed should have knee- or foot-operated faucets. It may be economical to reduce maintenance by using piping which can be easily decontaminated or replaced if required. In some cases it may be advisable to install underground holding or storage tanks to control the disposal of liquid radioactive materials.

                                                                                                                                                                                  Radiation Shielding Design

                                                                                                                                                                                  Shielding is important for reducing radiation exposure of facility workers and members of the general public. Shielding requirements depend on a number of factors, including the time that radiation workers or members of the public are exposed to the radiation sources and the type and energy of the radiation sources and radiation fields.

                                                                                                                                                                                  In the design of radiation shields, the shielding material should be placed near the radiation source if possible. Separate shielding considerations must be made for each type of radiation concerned.

                                                                                                                                                                                  Shielding design can be a complex task. For example, the use of computers to model shielding for accelerators, reactors and other high-level radiation sources is beyond the scope of this article. Qualified experts always should be consulted for complex shielding design.

                                                                                                                                                                                  Gamma source shielding

                                                                                                                                                                                  The attenuation of gamma radiation is qualitatively different from that of either alpha or beta radiation. Both of those types of radiation have a definite range in matter and are completely absorbed. Gamma radiation, on the other hand, can be reduced in intensity by increasingly thicker absorbers but it cannot be completely absorbed. If the attenuation of monoenergetic gamma rays is measured under conditions of good geometry (that is, the radiation is well collimated in a narrow beam) the intensity data, when plotted on a semi-log graph versus absorber thickness, will lie on a straight line with the slope equal to the attenuation
                                                                                                                                                                                  coefficient, μ.

                                                                                                                                                                                  The intensity or absorbed dose rate transmitted through an absorber can be calculated as follows:

                                                                                                                                                                                  I(t) = I(0)e μ t

                                                                                                                                                                                  where I(t) is the gamma-ray intensity or absorbed dose rate transmitted through an absorber of thickness t.

                                                                                                                                                                                  The units of μ and t are the reciprocal of each other. If the absorber thickness t is measured in cm, then μ is the linear attenuation coefficient and has units of cm–1. If t has units of areal density (g/cm2), then μ is the mass attenuation coefficient μm and has units of cm2/g.

                                                                                                                                                                                  As a first-order approximation using areal density, all materials have about the same photon attenuation properties for photons with energies between about 0.75 and 5.0 MeV (mega-electron volts). Within this energy range, gamma shielding properties are approximately proportional to the density of the shielding material. For lower or higher photon energies, absorbers of higher atomic number provide more effective shielding than those of lower atomic number, for a given areal density.

                                                                                                                                                                                  Under conditions of poor geometry (for example, for a broad beam or for a thick shield), the above equation will significantly underestimate the required shield thickness because it assumes that every photon that interacts with the shield will be removed from the beam and not be detected. A significant number of photons may be scattered by the shield into the detector, or photons that had been scattered out of the beam may be scattered back into it after a second interaction.

                                                                                                                                                                                  A shield thickness for conditions of poor geometry may be estimated through the use of the build-up factor B that may be estimated as follows:

                                                                                                                                                                                  I(t) = I(0)Be μ t

                                                                                                                                                                                  The build-up factor is always greater than one, and may be defined as the ratio of the intensity of the photon radiation, including both the primary and scattered radiation, at any point in the beam, to the intensity of the primary beam only at that point. The build-up factor may apply either to radiation flux or to absorbed dose rate.

                                                                                                                                                                                  Build-up factors have been calculated for various photon energies and various absorbers. Many of the graphs or tables give the shield thickness in terms of relaxation lengths. A relaxation length is the thickness of a shield that will attenuate a narrow beam to 1/e (about 37%) of its original intensity. One relaxation length, therefore, is numerically equal to the reciprocal of the linear attenuation coefficient (that is, 1/μ).

                                                                                                                                                                                  The thickness of an absorber that, when introduced into the primary photon beam, reduces the absorbed dose rate by one-half is called the half-value layer (HVL) or half-value thickness (HVT). The HVL may be calculated as follows:

                                                                                                                                                                                  HVL = ln2 / μ

                                                                                                                                                                                  The required photon shield thickness can be estimated by assuming narrow-beam or good geometry while calculating the required shielding, and then increasing the value thus found by one HVL to account for build-up.

                                                                                                                                                                                  The thickness of an absorber that, when introduced into the primary photon beam, reduces the absorbed dose rate by one-tenth is the tenth-value layer (TVL). One TVL is equal to about 3.32 HVLs, since:

                                                                                                                                                                                  ln10 / ln2 ≈ 3.32

                                                                                                                                                                                  Values for both TVLs and HVLs have been tabulated for various photon energies and several common shielding materials (e.g., lead, steel and concrete) (Schaeffer 1973).

                                                                                                                                                                                  The intensity or absorbed dose rate for a point source obeys the inverse square law and may be calculated as follows:

                                                                                                                                                                                  where Ii is the photon intensity or absorbed dose rate at distance di from the source.

                                                                                                                                                                                  Medical and non-medical x-ray equipment shielding

                                                                                                                                                                                  Shielding for x-ray equipment is considered under the two categories, source shielding and structural shielding. Source shielding is usually provided by the manufacturer of the x-ray tube housing.

                                                                                                                                                                                  Safety regulations specify one type of protective tube housing for medical diagnostic x-ray facilities and another type for medical therapeutic x-ray facilities. For non-medical x-ray equipment, the tube housing and other parts of the x-ray apparatus, such as the transformer, are shielded to reduce the leakage x-ray radiation to acceptable levels.

                                                                                                                                                                                  All x-ray machines, both medical and non-medical, have protective tube housings designed to limit the amount of leakage radiation. Leakage radiation, as used in these specifications for tube housings, means all radiation coming from the tube housing except for the useful beam.

                                                                                                                                                                                  Structural shielding for an x-ray facility provides protection from the useful or primary x-ray beam, from leakage radiation and from scatter radiation. It encloses both the x-ray equipment and the object being irradiated.

                                                                                                                                                                                  The amount of scatter radiation depends on the x-ray field size, energy of the useful beam, the effective atomic number of the scattering media and the angle between the incoming useful beam and the direction of scatter.

                                                                                                                                                                                  A key design parameter is the facility workload (W):

                                                                                                                                                                                  where W is the weekly workload, usually given in mA-min per week; E is the tube current multiplied by the exposure time per view, usually given in mA s; Nv is the number of views per patient or object irradiated; Np is the number of patients or objects per week and k is a conversion factor (1 min divided by 60 s).

                                                                                                                                                                                  Another key design parameter is the use factor Un for a wall (or floor or ceiling) n. The wall may be protecting any occupied area such as a control room, office or waiting room. The use factor is given by:

                                                                                                                                                                                  where, Nv,n is the number of views for which the primary x ray beam is directed toward wall n.

                                                                                                                                                                                  The structural shielding requirements for a given x ray facility are determined by the following:

                                                                                                                                                                                  • the maximum tube potential, in kilovolts-peak (kVp), at which the x ray tube is operated
                                                                                                                                                                                  • the maximum beam current, in mA, at which the x ray system is operated
                                                                                                                                                                                  • the workload (W), which is a measure, in suitable units (usually mA-min per week), of the amount of use of the x ray system
                                                                                                                                                                                  • the use factor (U), which is the fraction of the workload during which the useful beam is pointed in the direction of interest
                                                                                                                                                                                  • the occupancy factor (T), which is the factor by which the workload should be multiplied to correct for the degree or type of occupancy of the area to be protected
                                                                                                                                                                                  • the maximum permissible dose equivalent rate (P) to a person for controlled and non-controlled areas (typical absorbed dose limits are 1 mGy for a controlled area in one week and 0.1 mGy for a non-controlled area in one week)
                                                                                                                                                                                  • type of shielding material (for example, lead or concrete)
                                                                                                                                                                                  • the distance (d) from the source to the location being protected.

                                                                                                                                                                                   

                                                                                                                                                                                  With these considerations included, the value of the primary beam ratio or transmission factor K in mGy per mA-min at one metre is given by:

                                                                                                                                                                                  Shielding of the x-ray facility must be constructed so that protection is not impaired by joints; by openings for ducts, pipes and so on, that pass through the barriers; or by conduits, service boxes and so on, embedded in the barriers. The shielding should cover not only the back of the service boxes, but also the sides, or be extended sufficiently to offer equivalent protection. Conduits that pass through barriers should have sufficient bends to reduce the radiation to the required level. Observation windows must have shielding equivalent to that required for the partition (barrier) or door in which they are located.

                                                                                                                                                                                  Radiation therapy facilities may require door interlocks, warning lights, closed circuit television or means for audible (e.g., voice or buzzer) and visual communication between anyone who may be in the facility and the operator.

                                                                                                                                                                                  Protective barriers are of two types:

                                                                                                                                                                                  1. primary protective barriers, which are sufficient to attenuate the primary (useful) beam to the required level
                                                                                                                                                                                  2. secondary protective barriers, which are sufficient to attenuate leakage, scattered and stray radiation to the required level.

                                                                                                                                                                                   

                                                                                                                                                                                  To design the secondary protective barrier, separately calculate the required thickness to protect against each component. If the required thicknesses are about the same, add an additional HVL to the greatest calculated thickness. If the greatest difference between the calculated thicknesses is one TVL or more, the thickest of the calculated values will suffice.

                                                                                                                                                                                  Scattered radiation intensity depends on scattering angle, energy of the useful beam, field size or scattering area, and subject composition.

                                                                                                                                                                                  When designing secondary protective barriers, the following simplifying conservative assumptions are made:

                                                                                                                                                                                  1. When x rays are produced at 500 kV or less, the energy of the scattered radiation is equal to the energy of the useful beam.
                                                                                                                                                                                  2. After being scattered, the x-ray energy spectrum for beams generated at voltages greater than 500 kV are degraded to that of a 500 kV beam, and the absorbed dose rate at 1 m and 90 degrees from the scatterer is 0.1% of that in the useful beam at the point of scattering.

                                                                                                                                                                                   

                                                                                                                                                                                  The transmission relationship for scattered radiation is written in terms of the scattering transmission factor (Kμx) with units of mGy•m2 (mA-min)–1:

                                                                                                                                                                                  where P is the maximum weekly absorbed dose rate (in mGy), dscat is the distance from the x ray tube’s target and the object (patient), dsec is the distance from the scatterer (object) to the point of interest that the secondary barriers are meant to shield, a is the ratio of scattered radiation to incident radiation, f is the actual scattering field size (in cm2), and F is a factor accounting for the fact that x ray output increases with voltage. Smaller values of Kμx require thicker shields.

                                                                                                                                                                                  The leakage attenuation factor BLX for diagnostic x-ray systems is calculated as follows:

                                                                                                                                                                                  where d is the distance from the tube target to the point of interest and I is the tube current in mA.

                                                                                                                                                                                  The barrier attenuation relationship for therapeutic x-ray systems operating at 500 kV or less is given by:

                                                                                                                                                                                  For therapeutic x-ray tubes operating at potentials greater than 500 kV, the leakage is usually limited to 0.1% of the intensity of the useful beam at 1 m. The attenuation factor in this case is:

                                                                                                                                                                                  where Xn is the absorbed dose rate (in mGy/h) at 1 m from a therapeutic x-ray tube operated at a tube current of 1 mA.

                                                                                                                                                                                  The number n of HVLs required to obtain the desired attenuation BLX is obtained from the relationship:

                                                                                                                                                                                  or

                                                                                                                                                                                  Beta particle shielding

                                                                                                                                                                                  Two factors must be considered when designing a shield for a high-energy beta emitter. They are the beta particles themselves and the bremsstrahlung produced by beta particles absorbed in the source and in the shield. Bremsstrahlung consists of x-ray photons produced when high-speed charged particles undergo rapid deceleration.

                                                                                                                                                                                  Therefore, a beta shield often consists of a substance of low atomic number (to minimize bremsstrahlung production) that is thick enough to stop all the beta particles. This is followed by a material of high atomic number that is thick enough to attenuate bremsstrahlung to an acceptable level. (Reversing the order of the shields increases bremsstrahlung production in the first shield to a level so high that the second shield may provide inadequate protection.)

                                                                                                                                                                                  For purposes of estimating bremsstrahlung hazard, the following relationship may be used:

                                                                                                                                                                                  where f is the fraction of the incident beta energy converted into photons, Z is the atomic number of the absorber, and Eβ is the maximum energy of the beta particle spectrum in MeV. To assure adequate protection, it is normally assumed that all bremsstrahlung photons are of the maximum energy.

                                                                                                                                                                                  The bremsstrahlung flux F at a distance d from the beta source can be estimated as follows:

                                                                                                                                                                                  `Eβ is the average beta particle energy and can be estimated by:

                                                                                                                                                                                  The range Rβ of beta particles in units of areal density (mg/cm2) may be estimated as follows for beta particles with energies between 0.01 and 2.5 MeV:

                                                                                                                                                                                  where Rβ is in mg/cm2 and Eβ is in MeV.

                                                                                                                                                                                  For Eβ>2.5 MeV, the beta particle range Rβ may be estimated as follows:

                                                                                                                                                                                  where Rβ is in mg/cm2 and Eβ is in MeV.

                                                                                                                                                                                  Alpha particle shielding

                                                                                                                                                                                  Alpha particles are the least penetrating type of ionizing radiation. Because of the random nature of its interactions, the range of an individual alpha particle varies between nominal values as indicated in figure 1. Range in the case of alpha particles may be expressed in different ways: by minimum, mean, extrapolated, or maximum range. The mean range is the most accurately determinable, corresponds to the range of the “average” alpha particle, and is used most often.

                                                                                                                                                                                  Figure 1. Typical range distribution of alpha particles

                                                                                                                                                                                  ION040F1

                                                                                                                                                                                  Air is the most commonly used absorbing medium for specifying the range-energy relationship of alpha particles. For alpha energy Eα less than about 4 MeV, Rα in air is approximately given by:

                                                                                                                                                                                  where Rα is in cm, Eα in MeV.

                                                                                                                                                                                  For Eα between 4 and 8 MeV, Rα in air is given approximately by:

                                                                                                                                                                                  where Rα is in cm, Eα in MeV.

                                                                                                                                                                                  The range of alpha particles in any other medium may be estimated from the following relationship:

                                                                                                                                                                                  Rα (in other medium; mg/cm2) » 0.56 A1/3 Rα (in air; cm) where A is the atomic number of the medium.

                                                                                                                                                                                  Neutron shielding

                                                                                                                                                                                  As a general rule of thumb for neutron shielding, neutron energy equilibrium is achieved and then remains constant after one or two relaxation lengths of shielding material. Therefore, for shields thicker than a few relaxation lengths, the dose equivalent outside concrete or iron shielding will be attenuated with relaxation lengths of 120 g/cm2 or 145 g/cm2, respectively.

                                                                                                                                                                                  Neutron energy loss by elastic scattering requires a hydrogenous shield to maximize the energy transfer as the neutrons are moderated or slowed down. For neutron energies above 10 MeV, inelastic processes are effective in attenuating neutrons.

                                                                                                                                                                                  As with nuclear power reactors, high-energy accelerators require heavy shielding to protect workers. Most of the dose equivalents to workers come from exposure to activated radioactive material during maintenance operations. Activation products are produced in the accelerator’s components and support systems.

                                                                                                                                                                                  Monitoring of the Workplace Environment

                                                                                                                                                                                  It is necessary to deal separately with the design of routine and of operational monitoring programs for the workplace environment. Special monitoring programs will be designed to achieve specific objectives. It is not desirable to design programs in general terms.

                                                                                                                                                                                  Routine monitoring for external radiation

                                                                                                                                                                                  An important part in the preparation of a program for routine monitoring for external radiation in the workplace is to conduct a comprehensive survey when a new radiation source or a new facility is put into service, or when any substantial changes have been made or may have been made in an existing installation.

                                                                                                                                                                                  The frequency of routine monitoring is determined by consideration of the expected changes in the radiation environment. If changes to the protective equipment or alterations of the processes conducted in the workplace are minimal or non-substantial, then routine radiation monitoring of the workplace is rarely required for review purposes. If the radiation fields are subject to increase rapidly and unpredictably to potentially hazardous levels, then an area radiation monitoring and warning system is required.

                                                                                                                                                                                  Operational monitoring for external radiation

                                                                                                                                                                                  The design of an operational monitoring program depends greatly on whether the operations to be conducted influence the radiation fields or whether the radiation fields will remain substantially constant throughout normal operations. The detailed design of such a survey depends critically on the form of the operation and on the conditions under which it takes place.

                                                                                                                                                                                  Routine monitoring for surface contamination

                                                                                                                                                                                  The conventional method of routine monitoring for surface contamination is to monitor a representative fraction of the surfaces in an area at a frequency dictated by experience. If operations are such that considerable surface contamination is likely and such that workers could carry significant amounts of radioactive material out of the work area in a single event, routine monitoring should be supplemented by the use of portal contamination monitors.

                                                                                                                                                                                  Operational monitoring for surface contamination

                                                                                                                                                                                  One form of operational monitoring is the surveying of items for contamination when they leave a radiologically controlled area. This monitoring must include workers’ hands and feet.

                                                                                                                                                                                  The principle objectives of a program of monitoring for surface contamination are:

                                                                                                                                                                                  • to assist in preventing the spread of radioactive contamination
                                                                                                                                                                                  • to detect failures of containment or departures from good operating procedures
                                                                                                                                                                                  • to limit surface contamination to levels at which general standards of good housekeeping are adequate to keep radiation exposures as low as reasonably achievable and to avoid excessive exposures caused by contamination of clothing and skin
                                                                                                                                                                                  • to provide information for the planning of optimized programs for individuals, for air monitoring and for defining operational procedures.

                                                                                                                                                                                   

                                                                                                                                                                                  Monitoring for airborne contamination

                                                                                                                                                                                  The monitoring of airborne radioactive materials is important because inhalation is usually the most important route of intake of such material by radiation workers.

                                                                                                                                                                                  The monitoring of the workplace for airborne contamination will be needed on a routine basis in the following circumstances:

                                                                                                                                                                                  • when gaseous or volatile materials are handled in quantity
                                                                                                                                                                                  • when the handling of any radioactive material in such operations results in frequent and substantial contamination of the workplace
                                                                                                                                                                                  • during the processing of moderately to highly toxic radioactive materials
                                                                                                                                                                                  • during the handling of unsealed therapeutic radionuclides in hospitals
                                                                                                                                                                                  • during the use of hot cells, reactors and critical assemblies.

                                                                                                                                                                                   

                                                                                                                                                                                  When an air monitoring program is required, it must:

                                                                                                                                                                                  • be able to assess the probable upper limit of the inhalation of radioactive material by radiation workers
                                                                                                                                                                                  • be able to draw attention to unexpected airborne contamination so that radiation workers can be protected and remedial measures instituted
                                                                                                                                                                                  • provide information for planning of programs of individual monitoring for internal contamination.

                                                                                                                                                                                   

                                                                                                                                                                                  The most common form of monitoring for airborne contamination is the use of air samplers at a number of selected locations selected to be reasonably representative of the breathing zones of radiation workers. It may be necessary to make samples more accurately represent breathing zones by using personal air or lapel samplers.

                                                                                                                                                                                  Detection and measurement of radiation and radioactive contamination

                                                                                                                                                                                  The monitoring or surveying by wipes and instrument surveys of bench tops, floors, clothing, skin, and other surfaces are at best qualitative procedures. It is difficult to make them highly quantitative. The instruments used are usually detecting types rather than measuring devices. Since the amount of radioactivity involved is often small, the sensitivity of the instruments should be high.

                                                                                                                                                                                  The requirement for portability of contamination detectors depends on their intended uses. If the instrument is for general-purpose monitoring of laboratory surfaces, a portable type of instrument is desirable. If the instrument is for a specific use in which the item to be monitored can be brought to the instrument, then portability is not necessary. Clothing monitors and hand and shoe monitors generally are not portable.

                                                                                                                                                                                  Count-rate instruments and monitors usually incorporate meter readouts and aural outputs or earphone jacks. Table 4 identifies instruments that may be used for the detection of radioactive contamination.+

                                                                                                                                                                                  Table 4. Contamination detection instruments

                                                                                                                                                                                  Instrument

                                                                                                                                                                                  Counting rate range and other characteristics1

                                                                                                                                                                                  Typical uses

                                                                                                                                                                                  Remarks

                                                                                                                                                                                  bg surface monitors2

                                                                                                                                                                                  General

                                                                                                                                                                                  Portable count rate meter (thin-walled or thin window G-M3 counter)

                                                                                                                                                                                  0-1,000 cpm
                                                                                                                                                                                  0-10,000 cpm

                                                                                                                                                                                  Surfaces, hands, clothing

                                                                                                                                                                                  Simple, reliable, battery-powered

                                                                                                                                                                                  Thin end-window
                                                                                                                                                                                  G-M laboratory monitor

                                                                                                                                                                                  0-1,000 cpm
                                                                                                                                                                                  0-10,000 cpm
                                                                                                                                                                                  0-100,000 cpm

                                                                                                                                                                                  Surfaces, hands, clothing

                                                                                                                                                                                  Line-operated

                                                                                                                                                                                  Personnel

                                                                                                                                                                                  Hand-and-shoe monitor, G-M or
                                                                                                                                                                                  scintillator-type counter

                                                                                                                                                                                  Between 1½ and 2 times natural
                                                                                                                                                                                  background

                                                                                                                                                                                  Rapid monitoring for contamination

                                                                                                                                                                                  Automatic operation

                                                                                                                                                                                  Special

                                                                                                                                                                                  Laundry monitors, floor monitors,
                                                                                                                                                                                  doorway monitors, vehicle monitors

                                                                                                                                                                                  Between 1½ and 2 times natural
                                                                                                                                                                                  background

                                                                                                                                                                                  Monitoring for contamination

                                                                                                                                                                                  Convenient and rapid

                                                                                                                                                                                  Alpha surface monitors

                                                                                                                                                                                  General

                                                                                                                                                                                  Portable air proportional counter with probe

                                                                                                                                                                                  0-100,000 cpm over 100 cm2

                                                                                                                                                                                  Surfaces, hands, clothing

                                                                                                                                                                                  Not for use in high humidity, battery-
                                                                                                                                                                                  powered, fragile window

                                                                                                                                                                                  Portable gas-flow counter with probe

                                                                                                                                                                                  0-100,000 cpm over 100 cm2

                                                                                                                                                                                  Surfaces, hands, clothing

                                                                                                                                                                                  Battery-powered, fragile window

                                                                                                                                                                                  Portable scintillation counter with probe

                                                                                                                                                                                  0-100,000 cpm over 100 cm2

                                                                                                                                                                                  Surfaces, hands, clothing

                                                                                                                                                                                  Battery-powered, fragile window

                                                                                                                                                                                  Personal

                                                                                                                                                                                  Hand-and-shoe proportional counter-type, monitor

                                                                                                                                                                                  0-2,000 cpm over about 300 cm2

                                                                                                                                                                                  Rapid monitoring of hands and shoes for contamination

                                                                                                                                                                                  Automatic operation

                                                                                                                                                                                  Hand-and-shoe scintillation counter-type, monitor

                                                                                                                                                                                  0-4,000 cpm over about 300 cm2

                                                                                                                                                                                  Rapid monitoring of hands and shoes for contamination

                                                                                                                                                                                  Rugged

                                                                                                                                                                                  Wound monitors

                                                                                                                                                                                  Low-energy photon detection

                                                                                                                                                                                  Plutonium monitoring

                                                                                                                                                                                  Special design

                                                                                                                                                                                  Air monitors

                                                                                                                                                                                  Particle samplers

                                                                                                                                                                                  Filter paper, high-volume

                                                                                                                                                                                  1.1 m3/min

                                                                                                                                                                                  Quick grab samples

                                                                                                                                                                                  Intermittent use, requires separate
                                                                                                                                                                                  counter

                                                                                                                                                                                  Filter paper, low volume

                                                                                                                                                                                  0.2-20 m3/h

                                                                                                                                                                                  Continuous room air monitoring

                                                                                                                                                                                  Continuous use, requires separate
                                                                                                                                                                                  counter

                                                                                                                                                                                  Lapel

                                                                                                                                                                                  0.03 m3/min

                                                                                                                                                                                  Continuous breathing zone air monitoring

                                                                                                                                                                                  Continuous use, requires separate
                                                                                                                                                                                  counter

                                                                                                                                                                                  Electrostatic precipitator

                                                                                                                                                                                  0.09 m3/min

                                                                                                                                                                                  Continuous monitoring

                                                                                                                                                                                  Sample deposited on cylindrical shell,
                                                                                                                                                                                  requires separate counter

                                                                                                                                                                                  Impinger

                                                                                                                                                                                  0.6-1.1 m3/min

                                                                                                                                                                                  Alpha contamination

                                                                                                                                                                                  Special uses, requires separate counter

                                                                                                                                                                                  Tritium air monitors

                                                                                                                                                                                  Flow ionization chambers

                                                                                                                                                                                  0-370 kBq/m3 min

                                                                                                                                                                                  Continuous monitoring

                                                                                                                                                                                  May be sensitive to other ionization
                                                                                                                                                                                  sources

                                                                                                                                                                                  Complete air monitoring systems

                                                                                                                                                                                  Minimum detectable activity

                                                                                                                                                                                  Fixed filter paper

                                                                                                                                                                                  α » 0.04 Bq/m3; βγ » 0.04 Bq/m3

                                                                                                                                                                                   

                                                                                                                                                                                  Background buildup can mask low-level activity, counter included

                                                                                                                                                                                  Moving filter paper

                                                                                                                                                                                  α » 0.04 Bq/m3; βγ » 0.04 Bq/m3

                                                                                                                                                                                   

                                                                                                                                                                                  Continuous record of air activity, time of measurement can be adjusted from
                                                                                                                                                                                  time of  collection to any later time.

                                                                                                                                                                                  1 cpm = counts per minute.
                                                                                                                                                                                  2 Few surface monitors are suitable for detecting tritium (3H). Wipe tests counted by liquid scintillation devices are appropriate for detecting tritium contamination.
                                                                                                                                                                                  3 G-M = Geiger-Muller countrate meter.

                                                                                                                                                                                  Alpha contamination detectors

                                                                                                                                                                                  The sensitivity of an alpha detector is determined by its window area and window thickness. Generally window area is 50 cm2 or greater with a window areal density of 1 mg/cm2 or less. Alpha contamination monitors should be insensitive to beta and gamma radiation in order to minimize background interference. This is generally accomplished by pulse height discrimination in the counting circuit.

                                                                                                                                                                                  Portable alpha monitors can be either gas proportional counters or zinc sulphide scintillation counters.

                                                                                                                                                                                  Beta contamination detectors

                                                                                                                                                                                  Portable beta monitors of several types can be used for the detection of beta-particle contamination. Geiger-Mueller (G-M) count-rate meters generally require a thin window (areal density between 1 and 40 mg/cm2). Scintillation (anthracene or plastic) counters are very sensitive to beta particles and relatively insensitive to photons. Portable beta counters generally cannot be used to monitor for tritium (3H) contamination because tritium beta-particle energy is very low.

                                                                                                                                                                                  All instruments used for beta contamination monitoring also respond to background radiation. This must be taken into account when interpreting instrument readings.

                                                                                                                                                                                  When high background radiation levels exist, portable counters for contamination monitoring are of limited value, since they do not indicate small increases in initially high counting rates. Under these conditions smears or wipe tests are recommended.

                                                                                                                                                                                  Gamma contamination detectors

                                                                                                                                                                                  Since most gamma emitters also emit beta particles, most contamination monitors will detect both beta and gamma radiation. The usual practice is to use a detector that is sensitive to both types of radiation in order to have increased sensitivity, since the detection efficiency is usually greater for beta particles than for gamma rays. Plastic scintillators or sodium iodide (NaI) crystals are more sensitive to photons than are G-M counters, and are therefore recommended for detecting gamma rays.

                                                                                                                                                                                  Air samplers and monitors

                                                                                                                                                                                  Particulates may be sampled by the following methods: sedimentation, filtration, impaction and electrostatic or thermal precipitation. However, particulate contamination in the air is generally monitored by filtration (pumping air through filter media and measuring the radioactivity on the filter). Sampling flow rates generally are greater than 0.03 m3/min. However, most laboratories’ sampling flow rates are no more than 0.3 m3/min. Specific types of air samplers include “grab” samplers and continuous air monitors (CAM). The CAMs are available with either fixed or moving filter paper. A CAM should include an alarm since its principle function is to warn of changes in airborne contamination.

                                                                                                                                                                                  Because alpha particles have very short range, surface-loading filters (for example, membrane filters) must be used for the measurement of alpha-particle contamination. The sample collected must be thin. The time between collection and measurement must be considered to allow for the decay of radon (Rn) progeny.

                                                                                                                                                                                  Radioiodines such as 123I, 125I and 131I can be detected with filter paper (particularly if the paper is loaded with charcoal or silver nitrate) because some of the iodine will deposit on the filter paper. However, quantitative measurements require activated charcoal or silver zeolite traps or canisters to provide efficient absorption.

                                                                                                                                                                                  Tritiated water and tritium gas are the primary forms of tritium contamination. Although tritiated water has some affinity for most filter papers, filter paper techniques are not very effective for tritiated water sampling. The most sensitive and accurate measurement methods involve the absorption of tritiated water vapour condensate. Tritium in the air (for example, as hydrogen, hydrocarbons or water vapour) can be measured effectively with Kanne chambers (flow-through ionization chambers). Absorption of tritiated water vapour from an air sample can be accomplished by passing the sample through a trap containing a silica-gel molecular sieve or by bubbling the sample through distilled water.

                                                                                                                                                                                  Depending on the operation or process it may be necessary to monitor for radioactive gases. This can be accomplished with Kanne chambers. The most commonly used devices for sampling by absorption are fretted gas scrubbers and impingers. Many gases may also be collected by cooling the air below the freezing point of the gas and collecting the condensate. This method of collection is most often used for tritium oxide and noble gases.

                                                                                                                                                                                  There are a number of ways to obtain grab samples. The method selected should be appropriate for the gas to be sampled and the required method of analysis or measurement.

                                                                                                                                                                                  Monitoring of effluent

                                                                                                                                                                                  Effluent monitoring refers to the measurement of radioactivity at its point of release to the environment. It is relatively easy to accomplish because of the controlled nature of the sampling location, which is usually in a waste stream that is being discharged through a stack or liquid discharge line.

                                                                                                                                                                                  Continuous monitoring of airborne radioactivity may be necessary. In addition to the sample collection device, usually a filter, a typical sampling arrangement for particulates in air includes an air-moving device, a flowmeter and associated ducting. The air-moving device is located downstream from the sample collector; that is, the air is first passed through the sample collector, then through the remainder of the sampling system. Sampling lines, particularly those ahead of the sample collector system, should be kept as short as possible and free of sharp bends, areas of turbulence, or resistance to the air flow. Constant volume over a suitable range of pressure drops should be used for air sampling. Continuous sampling for radioactive xenon (Xe) or krypton (Kr) isotopes is accomplished by adsorption on activated charcoal or by cryogenic means. The Lucas cell is one of the oldest techniques and still the most popular method for the measurement of Rn concentrations.

                                                                                                                                                                                  Continuous monitoring of liquids and waste lines for radioactive materials is sometimes necessary. Waste lines from hot laboratories, nuclear medicine laboratories and reactor coolant lines are examples. Continuous monitoring can be performed, however, by routine laboratory analysis of a small sample proportional to the effluent flow rate. Samplers that take periodic aliquots or that continuously extract a small amount of liquid are available.

                                                                                                                                                                                  Grab sampling is the usual method used to determine the concentration of radioactive material in a hold-up tank. The sample must be taken after recirculation in order to compare the result of the measurement with allowable discharge rates.

                                                                                                                                                                                  Ideally, results of effluent monitoring and environmental monitoring will be in good agreement, with the latter calculable from the former with the aid of various pathway models. However, it must be recognized and emphasized that effluent monitoring, no matter how good or extensive, cannot substitute for actual measurement of radiological conditions in the environment.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 19:42

                                                                                                                                                                                  Journalism

                                                                                                                                                                                  Journalism is one of the romantic professions, but it is also one of the most dangerous. Between 1990 and 1997 more than 500 journalists and media workers were killed, many the victims of gangsters, paramilitary groups and terrorists. Each year, hundreds of reporters and writers are injured, both physically and psychologically, by the horrors of war and social conflict. See figure 1.

                                                                                                                                                                                  Figure 1.  Algiers, Algeria, 11 February 1996: The devastated offices of Le Soir, one of three newspapers hit by a terrorist car bomb.

                                                                                                                                                                                  ENT236F2

                                                                                                                                                                                  Le Soir

                                                                                                                                                                                  The tendency to try to manipulate or control information is becoming more evident as the speed and range of communication increases. Today information speeds around the world in seconds thanks to satellite technology. News and information can be beamed into people’s homes as it happens.

                                                                                                                                                                                  Consequently, journalists and their visible helpers—camera and technical staff, for instance—pose a threat to any group, official or otherwise, that wants to avoid public scrutiny. This leads to specific and targeted attacks on journalists and media organizations.

                                                                                                                                                                                  The problem of “censorship by violence” is exacerbated by the nature of commercial competition in the media industry and by unregulated patterns of employment. Media networks compete vigorously for market share, and this is leading to greater pressure on journalists to provide ever more dramatic and sensationalist images and reportage. Many media people are taking greater risks than before.

                                                                                                                                                                                  The situation is made worse because few media organizations provide training for their staff in how to deal with situations of violence and conflict. Such training is essential. Media staff need to be able to make coherent and sensible “risk assessment” judgements about fast-moving reporting situations. They need a basic knowledge of first aid and advice from media veterans on how to report from dangerous scenes.

                                                                                                                                                                                  The most vulnerable group of media workers—freelance journalists and casual staff—are the ones least likely to receive training even where it is available. More freelance staff are employed than ever before and many of them are hired from the regions where the reported action is taking place. Sometimes they are hired without any life or health insurance. If they get hurt, they are not entitled to compensation.

                                                                                                                                                                                  Because they often work in very unpredictable circumstances, some journalists will always be at risk. Often it will be impossible to avoid injury, even death. But much more can be done to minimize the levels of risk. For instance, in Algeria, where some 60 journalists were assassinated between June 1994 and March 1996, journalists’ unions, employers and the authorities have combined their efforts to minimize risks.

                                                                                                                                                                                  Much more needs to be done by media organizations and representatives of media workers and journalists to provide protections for media personnel. In particular there is a need for:

                                                                                                                                                                                  • Adequate preparation by journalists and media before going on assignment. Media organizations should provide technical assistance and establish training programmes specifically designed to improve levels of personal safety and to carry out risk assessment related to specific assignments.
                                                                                                                                                                                  • Health and life insurance for everyone reporting in the field, with established procedures to ensure that anyone who is likely to be at risk, including freelance staff or stringers, is covered.

                                                                                                                                                                                   

                                                                                                                                                                                  In addition, media organizations must reverse recent trends that undermine the social and professional conditions in which journalists work. There should be increased investment in professional training and journalistic ethics to emphasize the importance of investigative journalism to the good health of democratic society.

                                                                                                                                                                                  Journalists themselves have a key role to play. All journalists must take responsibility to exercise the highest standards of personal safety and minimize risks to themselves and their colleagues. Journalists need to maintain the highest professional standards and conduct and should not compromise the ethics of journalism in any aspect of the gathering, production or dissemination of news and information.

                                                                                                                                                                                  But it is not only the professionals that need to take practical steps to address the issue. Governments, which have a responsibility to protect the lives and security of citizens, must ensure that journalists and media organizations are provided with the maximum security and protection from violence.

                                                                                                                                                                                  Government and public authorities must not regard journalists as part of the state security apparatus and must not demand information or materials from media organizations in order to assist inquiries which are the responsibility of official agencies.

                                                                                                                                                                                  One of the worrying features of journalism has always been that governments are prepared to use the cover of journalistic activity in order to carry out surveillance and espionage. It is a practice which exposes all travelling journalists to suspicion and intimidation.

                                                                                                                                                                                  The key is to reduce the risk. There are no absolute guarantees of safety, but governments, journalists and media organizations need to avoid creating the conditions which make it easier to commit violence against media. A starting point would be recognition that no single story, no matter how dramatic, is worth a life.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 19:16

                                                                                                                                                                                  Sources of Ionizing Radiation

                                                                                                                                                                                  Ionizing Radiation Types

                                                                                                                                                                                  Alpha particles

                                                                                                                                                                                  An alpha particle is a tightly bound collection of two protons and two neutrons. It is identical to a helium-4 (4He) nucleus. Indeed, its ultimate fate after it loses most of its kinetic energy is to capture two electrons and become a helium atom.

                                                                                                                                                                                  Alpha-emitting radionuclides are generally relatively massive nuclei. Almost all alpha emitters have atomic numbers greater than or equal to that of lead (82Pb). When a nucleus decays by emitting an alpha particle, both its atomic number (number of protons) and its number of neutrons are reduced by two and its atomic mass number is reduced by four. For example, the alpha decay of uranium-238 (238U) to thorium-234 (234Th) is represented by:

                                                                                                                                                                                  The left superscript is the atomic mass number (number of protons plus neutrons), the left subscript is the atomic number (number of protons), and the right subscript is the number of neutrons.

                                                                                                                                                                                  Common alpha emitters emit alpha particles with kinetic energies between about 4 and 5.5 MeV. Such alpha particles have a range in air of no more than about 5 cm (see figure 1). Alpha particles with an energy of at least 7.5 MeV are required to penetrate the epidermis (the protective layer of skin, 0.07 mm thick). Alpha emitters generally do not pose an external radiation hazard. They are hazardous only if taken within the body. Because they deposit their energy in a short distance, alpha particles are high linear energy transfer (LET) radiation and have a large radiation weighting factor; typically, w R=20.

                                                                                                                                                                                  Figure 1. Range-energy radiation of slow alpha particles in air at 15 and 760 m

                                                                                                                                                                                   

                                                                                                                                                                                  ION030F1

                                                                                                                                                                                   

                                                                                                                                                                                  Beta particles

                                                                                                                                                                                  A beta particle is a highly energetic electron or positron. (A positron is the anti-particle of the electron. It has the same mass and most other properties of an electron except for its charge, which is exactly the same magnitude as that of an electron but is positive.) Beta-emitting radionuclides can be of high or low atomic weight.

                                                                                                                                                                                  Radionuclides that have an excess of protons in comparison with stable nuclides of about the same atomic mass number can decay when a proton in the nucleus converts to a neutron. When this occurs, the nucleus emits a positron and an extremely light, very non-interacting particle called a neutrino. (The neutrino and its anti-particle are of no interest in radiation protection.) When it has given up most of its kinetic energy, the positron ultimately collides with an electron and both are annihilated. The annihilation radiation produced is almost always two 0.511 keV (kiloelectron volt) photons travelling in directions 180 degrees apart. A typical positron decay is represented by:

                                                                                                                                                                                  where the positron is represented by β+ and the neutrino by n. Note that the resulting nuclide has the same atomic mass number as the parent nuclide and an atomic (proton) number larger by one and a neutron number lesser by one than those of the original nuclide.

                                                                                                                                                                                  Electron capture competes with positron decay. In electron capture decay, the nucleus absorbs an orbital electron and emits a neutrino. A typical electron capture decay is given by:

                                                                                                                                                                                  Electron capture is always possible when the resulting nucleus has a lower total energy than the initial nucleus. However, positron decay requires that the total energy of the initial atom is greater than that of the resulting atom by more than 1.02 MeV (twice the rest mass energy of the positron).

                                                                                                                                                                                  Similar to positron and electron capture decay, negatron (β) decay occurs for nuclei that have an excess of neutrons compared to stable nuclei of about the same atomic mass number. In this case, the nucleus emits a negatron (energetic electron) and an anti-neutrino. A typical negatron decay is represented by:

                                                                                                                                                                                  where the negatron is represented by β and the anti-neutrino by`n Here the resulting nucleus gains one neutron at the expense of one proton but again does not change its atomic mass number.

                                                                                                                                                                                  Alpha decay is a two-body reaction, so alpha particles are emitted with discrete kinetic energies. However, beta decay is a three-body reaction, so beta particles are emitted over a spectrum of energies. The maximum energy in the spectrum depends on the decaying radionuclide. The average beta energy in the spectrum is approximately one-third of the maximum energy (see figure 2).

                                                                                                                                                                                  Figure 2. Energy spectrum of negatrons emitted from 32P

                                                                                                                                                                                  ION030F2

                                                                                                                                                                                  Typical maximum beta energies range from 18.6 keV for tritium (3H) to 1.71 MeV for phosphorus-32 (32P).

                                                                                                                                                                                  The range of beta particles in air is approximately 3.65 m per MeV of kinetic energy. Beta particles of at least 70 keV energy are required to penetrate the epidermis. Beta particles are low-LET radiation.

                                                                                                                                                                                   

                                                                                                                                                                                  Gamma radiation

                                                                                                                                                                                  Gamma radiation is electromagnetic radiation emitted by a nucleus when it undergoes a transition from a higher to a lower energy state. The number of protons and neutrons in the nucleus does not change in such a transition. The nucleus may have been left in the higher energy state following an earlier alpha or beta decay. That is, gamma rays are often emitted immediately following alpha or beta decays. Gamma rays can also result from neutron capture and inelastic scattering of subatomic particles by nuclei. The most energetic gamma rays have been observed in cosmic rays.

                                                                                                                                                                                  Figure 3 is a picture of the decay scheme for cobalt-60 (60Co). It shows a cascade of two gamma rays emitted in nickel-60 (60Ni) with energies of 1.17 MeV and 1.33 MeV following the beta decay of 60Co.

                                                                                                                                                                                  Figure 3. Radioactive decay scheme for 60Co

                                                                                                                                                                                  ION030F3

                                                                                                                                                                                  Figure 4 is a picture of the decay scheme for molybdenum-99 (99Mo). Note that the resulting technetium-99 (99Tc) nucleus has an excited state that lasts for an exceptionally long time (t½ = 6 h). Such an excited nucleus is called an isomer. Most excited nuclear states have half-lives between a few picoseconds (ps) and 1 microsecond (μs).

                                                                                                                                                                                  Figure 4. Radioactive decay scheme for 99Mo

                                                                                                                                                                                  ION030F4

                                                                                                                                                                                  Figure 5 is a picture of the decay scheme for arsenic-74 (74As). It illustrates that some radionuclides decay in more than one way.

                                                                                                                                                                                  Figure 5. Radioactive decay scheme for 74As, illustrating competing processes of negatron emission, positron emission and electron capture (m0 is the rest mass of the electron)

                                                                                                                                                                                  ION030F5

                                                                                                                                                                                  While alpha and beta particles have definite ranges in matter, gamma rays are attenuated exponentially (ignoring build-up that results from scattering within a material) as they pass through matter. When build-up can be ignored the attenuation of gamma rays is given by:

                                                                                                                                                                                  where I(x) is the gamma ray intensity as a function of distance x into the material and μ is the mass attenuation coefficient. The mass attenuation coefficient depends on gamma-ray energy and on the material with which the gamma rays are interacting. Mass attenuation coefficient values are tabulated in many references. Figure 6 shows the absorption of gamma rays in matter in conditions of good geometry (build-up can be ignored).

                                                                                                                                                                                  Figure 6. Atenuation of 667 keV gamma rays in Al and Pb under conditions of good geometry (dashed line represents attenuation of a poly-energetic photon beam)

                                                                                                                                                                                  ION030F6

                                                                                                                                                                                  Build-up occurs when a broad gamma-ray beam interacts with matter. The measured intensity at points within the material is increased relative to the expected “good geometry” (narrow beam) value due to gamma rays scattered from the sides of the direct beam into the measuring device. The degree of build-up depends on the geometry of the beam, on the material and on the energy of the gamma rays.

                                                                                                                                                                                  Internal conversion competes with gamma emission when a nucleus transforms from a higher energy state to a lower one. In internal conversion, an inner orbital electron is ejected from the atom instead of the nucleus emitting a gamma ray. The ejected electron is directly ionizing. As outer orbital electrons drop to lower electronic energy levels to fill the vacancy left by the ejected electron, the atom emits x rays. Internal conversion probability relative to gamma emission probability increases with increasing atomic number.

                                                                                                                                                                                  X rays

                                                                                                                                                                                  X rays are electromagnetic radiation and, as such, are identical to gamma rays. The distinction between x rays and gamma rays is their origin. Whereas gamma rays originate in the atomic nucleus, x rays result from electron interactions. Although x rays often have lower energies than gamma rays, this is not a criterion for differentiating them. It is possible to produce x rays with energies much higher than gamma rays resulting from radioactive decay.

                                                                                                                                                                                  Internal conversion, discussed above, is one method of x ray production. In this case, the resulting x rays have discrete energies equal to the difference in the energy levels between which the orbital electrons transit.

                                                                                                                                                                                  Charged particles emit electromagnetic radiation whenever they are accelerated or decelerated. The amount of radiation emitted is inversely proportional to the fourth power of the particle’s mass. As a result, electrons emit much more x radiation than heavier particles such as protons, all other conditions being equal. X-ray systems produce x rays by accelerating electrons across a large electric potential difference of many kV or MV. The electrons are then quickly decelerated in a dense, heat-resistant material, such as tungsten (W).

                                                                                                                                                                                  The x rays emitted from such systems have energies spread over a spectrum ranging from about zero up to the maximum kinetic energy possessed by the electrons before deceleration. Often superimposed on this continuous spectrum are x rays of discrete energy. They are produced when the decelerating electrons ionize the target material. As other orbital electrons move to fill vacancies left after ionization, they emit x rays of discrete energies similar to the way x rays are emitted following internal conversion. They are called characteristic x rays because they are characteristic of the target (anode) material. See figure 7 for a typical x ray spectrum. Figure 8 depicts a typical x ray tube.

                                                                                                                                                                                  Figure 7. X-ray spectrum illustrating the contribution of characteristic x rays produced as electrons fill holes in the K shell of W (the wavelength of x rays is inversely proportional to their energy)

                                                                                                                                                                                  ION030F7

                                                                                                                                                                                  X rays interact with matter the same way gamma rays do, but a simple exponential attenuation equation does not adequately describe the attenuation of x rays with a continuous range of energies (see figure 6). However, as lower energy x rays are removed more rapidly from the beam than higher energy x rays as they pass through material, the description of attenuation approaches an exponential function.

                                                                                                                                                                                   

                                                                                                                                                                                   

                                                                                                                                                                                   

                                                                                                                                                                                   

                                                                                                                                                                                   

                                                                                                                                                                                  Figure 8. A simplified x-ray tube with a stationary anode and a heated filament

                                                                                                                                                                                  ION030F8

                                                                                                                                                                                  Neutrons

                                                                                                                                                                                  Generally, neutrons are not emitted as a direct result of natural radioactive decay. They are produced during nuclear reactions. Nuclear reactors produce neutrons in the greatest abundance but particle accelerators and special neutron sources, called (α, n) sources, also can yield neutrons.

                                                                                                                                                                                  Nuclear reactors produce neutrons when uranium (U) nuclei in nuclear fuel split, or fission. Indeed, the production of neutrons is essential in maintaining nuclear fission in a reactor.

                                                                                                                                                                                  Particle accelerators produce neutrons by accelerating charged particles, such as protons or electrons, to high energies to bombard stable nuclei in a target. Neutrons are only one of the particles that can result from such nuclear reactions. For example, the following reaction produces neutrons in a cyclotron that is accelerating deuterium ions to bombard a beryllium target:

                                                                                                                                                                                  Alpha emitters mixed with beryllium are portable sources of neutrons. These (α, n) sources produce neutrons via the reaction:

                                                                                                                                                                                  The source of the alpha particles can be such isotopes as polonium-210 (210Po),
                                                                                                                                                                                  plutonium-239 (239Pu) and americium-241 (241Am).

                                                                                                                                                                                  Neutrons are generally classified according to their energy as illustrated in table 1. This classification is somewhat arbitrary and may vary in different contexts.

                                                                                                                                                                                  Table 1. Classification of neutrons according to kinetic energy

                                                                                                                                                                                  Type

                                                                                                                                                                                  Energy range

                                                                                                                                                                                  Slow or thermal

                                                                                                                                                                                  0-0.1 keV

                                                                                                                                                                                  Intermediate

                                                                                                                                                                                  0.1-20 keV

                                                                                                                                                                                  Fast

                                                                                                                                                                                  20 keV-10 MeV

                                                                                                                                                                                  High-energy

                                                                                                                                                                                  >10 MeV

                                                                                                                                                                                   

                                                                                                                                                                                  A number of possible modes of neutron interaction with matter exist, but the two main modes for the purposes of radiation safety are elastic scattering and neutron capture.

                                                                                                                                                                                  Elastic scattering is the means by which higher-energy neutrons are reduced to thermal energies. Higher-energy neutrons interact primarily by elastic scattering and generally do not cause fission or produce radioactive material by neutron capture. It is thermal neutrons that are primarily responsible for the latter types of interaction.

                                                                                                                                                                                  Elastic scattering occurs when a neutron interacts with a nucleus and bounces off with reduced energy. The interacting nucleus takes up the kinetic energy the neutron loses. After being excited in this manner, the nucleus soon gives up this energy as gamma radiation.

                                                                                                                                                                                  When the neutron eventually reaches thermal energies (so-called because the neutron is in thermal equilibrium with its environment), it is easily captured by most nuclei. Neutrons, having no charge, are not repelled by the positively charged nucleus as are protons. When a thermal neutron approaches a nucleus and comes within the range of the strong nuclear force, on the order of a few fm (fm = 10–15 metres), the nucleus captures the neutron. The result can then be a radioactive nucleus that emits a photon or other particle or, in the case of fissionable nuclei such as 235U and 239Pu, the capturing nucleus can fission into two smaller nuclei and more neutrons.

                                                                                                                                                                                  The laws of kinematics indicate that neutrons will reach thermal energies more rapidly if the elastic scattering medium includes a large number of light nuclei. A neutron rebounding off a light nucleus loses a much larger percentage of its kinetic energy than when it bounces off of a heavy nucleus. For this reason, water and hydrogenous materials are the best shielding material to slow down neutrons.

                                                                                                                                                                                  A monoenergetic beam of neutrons will attenuate exponentially in material, obeying an equation similar to that given above for photons. The probability of a neutron interacting with a given nucleus is described in terms of the quantity cross section. Cross section has units of area. The special unit for cross section is the barn (b), defined by:

                                                                                                                                                                                  It is extremely difficult to produce neutrons without accompanying gamma and x rays. It may be generally assumed that if neutrons are present, so are high energy photons.

                                                                                                                                                                                  Ionizing Radiation Sources

                                                                                                                                                                                  Primordial radionuclides

                                                                                                                                                                                  Primordial radionuclides occur in nature because their half-lives are comparable with the age of the earth. Table 2 lists the most important primordial radionuclides.

                                                                                                                                                                                  Table 2. Primordial radionuclides

                                                                                                                                                                                  Radioisotope

                                                                                                                                                                                  Half-life (109 Y)

                                                                                                                                                                                  Abundance (%)

                                                                                                                                                                                  238U

                                                                                                                                                                                  4.47

                                                                                                                                                                                  99.3

                                                                                                                                                                                  232Th

                                                                                                                                                                                  14.0

                                                                                                                                                                                  100

                                                                                                                                                                                  235U

                                                                                                                                                                                  0.704

                                                                                                                                                                                  0.720

                                                                                                                                                                                  40K

                                                                                                                                                                                  1.25

                                                                                                                                                                                  0.0117

                                                                                                                                                                                  87Rb

                                                                                                                                                                                  48.9

                                                                                                                                                                                  27.9

                                                                                                                                                                                   

                                                                                                                                                                                  Uranium and thorium isotopes head a long chain of progeny radioisotopes that, as a result, are also naturally occurring. Figure 9, A-C, illustrates the decay chains for 232Th, 238U and 235U, respectively. Because alpha decay is common above atomic mass number 205 and an alpha particle’s atomic mass number is 4, there are four distinct decay chains for heavy nuclei. One of these chains (see figure 9, D), that for 237Np, does not occur in nature. This is because it does not contain a primordial radionuclide (that is, no radionuclide in this chain has a half-life comparable with the age of the earth).

                                                                                                                                                                                  Figure 9. Decay series (Z = atomic number; N = atomic mass number)    

                                                                                                                                                                                   ION030F9Note that radon (Rn) isotopes occur in each chain (219Rn, 220Rn and 222Rn). Since Rn is a gas, once Rn is produced, it has a chance of escape to the atmosphere from the matrix in which it was formed. However, the half-life of 219Rn is much too short to allow significant amounts of it to reach a breathing zone. The relatively short half-life of 220Rn usually makes it a lesser health hazard concern than 222Rn.

                                                                                                                                                                                  Not including Rn, primordial radionuclides external to the body deliver on the average about 0.3 mSv annual effective dose to the human population. The actual annual effective dose varies widely and is determined primarily by the concentration of uranium and thorium in the local soil. In some parts of the world where monazite sands are common, the annual effective dose to a member of the population is as high as about 20 mSv. In                                                                                                                           other places such as on coral atolls and near seashores, the                                                                                                                           value may be as low as 0.03 mSv (see figure 9).

                                                                                                                                                                                  Radon is usually considered separately from other naturally occurring terrestrial radionuclides. It seeps into the air from the soil. Once in the air, Rn further decays to radioactive isotopes of Po, bismuth (Bi) and Pb. These progeny radionuclides attach themselves to dust particles that may be breathed in and trapped in the lungs. Being alpha emitters, they deliver almost all of their radiation energy to the lungs. It is estimated that the average annual lung equivalent dose from such exposure is about 20 mSv. This lung equivalent dose is comparable to a whole body effective dose of about 2 mSv. Clearly, Rn and its progeny radionuclides are the most significant contributors to background radiation effective dose (see figure 9).

                                                                                                                                                                                  Cosmic rays

                                                                                                                                                                                  Cosmic radiation includes energetic particles of extraterrestrial origin that strike the atmosphere of the earth (primarily particles and mostly protons). It also includes secondary particles; mostly photons, neutrons and muons, generated by interactions of primary particles with gases in the atmosphere.

                                                                                                                                                                                  By virtue of these interactions, the atmosphere serves as a shield against cosmic radiation, and the thinner this shield, the greater the effective dose rate. Thus, the cosmic-ray effective dose rate increases with altitude. For example, the dose rate at an altitude of 1,800 metres is about double that at sea level.

                                                                                                                                                                                  Because primary cosmic radiation consists mostly of charged particles, it is influenced by the earth’s magnetic field. People living in higher latitudes receive greater effective doses of cosmic radiation than those closer to the earth’s equator. Variation due to this effect is of the order
                                                                                                                                                                                  of 10%.

                                                                                                                                                                                  Finally, the cosmic-ray effective dose rate varies according to modulation of the sun’s cosmic-ray output. On the average, cosmic rays contribute about 0.3 mSv to background radiation whole-body effective dose.

                                                                                                                                                                                  Cosmogenic radionuclides

                                                                                                                                                                                  Cosmic rays produce cosmogenic radionuclides in the atmosphere. The most prominent of these are tritium (3H), beryllium-7 (7Be), carbon-14 (14C) and sodium-22 (22Na). They are produced by cosmic rays interacting with atmospheric gases. Cosmogenic radionuclides deliver about 0.01 mSv annual effective dose. Most of this comes from 14C.

                                                                                                                                                                                  Nuclear fallout

                                                                                                                                                                                  From the 1940s through the 1960s, extensive testing of nuclear weapons above ground occurred. This testing produced large quantities of radioactive materials and distributed them to the environment throughout the world as fallout. Although much of this debris has since decayed to stable isotopes, small amounts that remain will be a source of exposure for many years to come. In addition, nations that continue to occasionally test nuclear weapons in the atmosphere add to the worldwide inventory.

                                                                                                                                                                                  The primary fallout contributors to effective dose currently are strontium-90 (90Sr) and caesium-137 (137Cs), both of which have half-lives around 30 years. The average annual effective dose from fallout is about 0.05 mSv.

                                                                                                                                                                                  Radioactive material in the body

                                                                                                                                                                                  The deposition of naturally occurring radionuclides in the human body results primarily from the inhalation and ingestion of these materials in air, food and water. Such nuclides include radioisotopes of Pb, Po, Bi, Ra, K (potassium), C, H, U and Th. Of these, 40K is the largest contributor. Naturally occurring radionuclides deposited in the body contribute about 0.3 mSv to the annual effective dose.

                                                                                                                                                                                  Machine-produced radiation

                                                                                                                                                                                  The use of x rays in the healing arts is the largest source of exposure to machine-produced radiation. Millions of medical x ray systems are in use around the world. The average exposure to these medical x ray systems is greatly dependent on a population’s access to care. In developed countries, the average annual effective dose from medically prescribed radiation from x rays and radioactive material for diagnosis and therapy is on the order of 1 mSv.

                                                                                                                                                                                  X rays are a by-product of most high-energy physics particle accelerators, especially those that accelerate electrons and positrons. However, appropriate shielding and safety precautions plus the limited population at risk make this source of radiation exposure less significant than the above sources.

                                                                                                                                                                                  Machine-produced radionuclides

                                                                                                                                                                                  Particle accelerators can produce a large variety of radionuclides in varying quantities by way of nuclear reactions. Accelerated particles include protons, deuterons (2H nuclei), alpha particles, charged mesons, heavy ions and so on. Target materials can be made of almost any isotope.

                                                                                                                                                                                  Particle accelerators are virtually the only source for positron-emitting radioisotopes. (Nuclear reactors tend to produce neutron-rich radioisotopes that decay by negatron emission.) They are also being increasingly used to produce short-lived isotopes for medical use, especially for positron-emission tomography (PET).

                                                                                                                                                                                  Technologically enhanced material and consumer products

                                                                                                                                                                                  X rays and radioactive materials appear, wanted and unwanted, in a great number of modern-day operations. Table 3 lists these radiation sources.

                                                                                                                                                                                  Table 3. Sources and estimates of associated population effective doses from technologically enhanced material and consumer products

                                                                                                                                                                                  Group I - Involves large numbers of people and the individual effective dose is very
                                                                                                                                                                                  large

                                                                                                                                                                                  Tobacco products

                                                                                                                                                                                  Combustible fuels

                                                                                                                                                                                  Domestic water supplies

                                                                                                                                                                                  Glass and ceramics

                                                                                                                                                                                  Building materials

                                                                                                                                                                                  Ophthalmic glass

                                                                                                                                                                                  Mining and agricultural products

                                                                                                                                                                                   

                                                                                                                                                                                  Group II - Involves many people but the effective dose is relatively small or is limited
                                                                                                                                                                                  to a small portion of the body

                                                                                                                                                                                  Television receivers

                                                                                                                                                                                  Highway and road construction materials

                                                                                                                                                                                  Radioluminous products

                                                                                                                                                                                  Aircraft transport of radioactive materials

                                                                                                                                                                                  Airport inspection systems

                                                                                                                                                                                  Spark gap irradiators and electron tubes

                                                                                                                                                                                  Gas and aerosol (smoke) detectors

                                                                                                                                                                                  Thorium products - fluorescent lamp starters
                                                                                                                                                                                  and gas mantles

                                                                                                                                                                                  Group III - Involves relatively few people and the collective effective dose is small

                                                                                                                                                                                  Thorium products - tungsten welding rods

                                                                                                                                                                                   

                                                                                                                                                                                  Source: NCRP 1987.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 19:38

                                                                                                                                                                                  Radio and Television Broadcasting

                                                                                                                                                                                  The production of television and radio broadcasts involves camera shoots and recordings on location and in the studio, video- and audiotape editing, transmitting and receiving broadcasts, managing electronic information and graphics, and maintenance of equipment and tape. Broadcast engineers and technicians produce pre-taped and live broadcasts for major network and cable companies, local stations and production companies. Major occupations include: camera operator, sound person, tape editor, computer operator, maintenance engineer, news broadcaster and other television and radio artists.

                                                                                                                                                                                  Broadcasting and its support activities can take place in remote locations, in the studio or in various maintenance and specialty shops. Employees can be exposed to many hazards typical of the technological workplace, including poor indoor air quality, poor workplace design and low-frequency electromagnetic radiation (since microwave technology is used to transmit and receive broadcasts, and the density of electronic equipment produces relatively high levels of low-frequency energy fields). Proper shielding and placement of equipment are prudent measures to protect operators from these fields.

                                                                                                                                                                                  Hazards and Precautions

                                                                                                                                                                                  Remote locations

                                                                                                                                                                                  Roving camera and audio crews cover news and special events for networks and local stations. Crews carry to the site everything needed for the broadcast, including camera, sound recorder, lights, tripod and electrical cords. Since the advent of lightweight cameras equipped with sound recorders, a single person may be assigned to operate the equipment. The hazards can include trips, slips and falls and musculoskeletal stress. Violence in riots and wars can lead to injuries and fatalities. Bad weather, crowds, environmental disasters and rough terrain increase the potential for serious injuries and illnesses among the crew.

                                                                                                                                                                                  The danger can be reduced through assessing the location for the potential for violence and the securing of safe operating locations. Personal protective equipment, such as bullet-proof vests and helmets, may also be needed. Adequate staffing and material-handling equipment and safe lifting practices can reduce musculoskeletal stresses.

                                                                                                                                                                                  News and traffic reports are frequently recorded or aired from helicopters. Broadcast personnel have been killed and injured in crashes and unplanned landings. Strict adherence to proper training and certification of pilots, preventive maintenance of equipment and prohibition of unsafe flying practices (such as flying too close to other helicopters or to structures) are crucial for protecting these employees. See the article “Heliocopters” elsewhere in this volume.

                                                                                                                                                                                  Sporting events, such as golf tournaments and car races, and other special events are often shot from elevated platforms and scaffolds. Motorized lifts and cranes are also used to position equipment and personnel. These structures and machines are typical of those used in general building construction and motion picture production, and one may encounter the same hazards, such as falling off the structure, being struck by falling objects, being struck by lightning in open areas and being electrocuted from contact with overhead power lines and live electrical equipment.

                                                                                                                                                                                  Proper inspection and erection of platforms, full guardrails with toe boards to prevent objects from falling, access ladders, grounding and guarding of electrical equipment and observance of weather alerts, as in construction work, are some appropriate precautions to be taken.

                                                                                                                                                                                  Studio productions

                                                                                                                                                                                  Studio productions have the advantages of familiar surroundings where employees operate cameras, sound equipment and special effects equipment. The hazards are similar to those described in motion picture production and include: musculoskeletal stresses, electrical hazards, noise (especially in rock radio studios) and exposure to theatrical smokes and fogs. Appropriate ergonomic design of work spaces and equipment, electrical safeguards, control of sound levels, careful selection of smokes and fogs and adequate ventilation are all possible preventive measures.

                                                                                                                                                                                  Film editing, handling and storage

                                                                                                                                                                                  Before being broadcast, video- and audiotapes must be edited. The conditions will depend on the size of the facility, but it is not uncommon for several editing operations to be going on at the same time. Editing work requires close attention to the material, and editing rooms can be noisy, overcrowded and poorly lit, with poor indoor air quality and electrical hazards. The space and the equipment can have poor ergonomic design; tasks may be repetitive. There may be noise and fire hazards. Proper workspace design including space, lighting and ventilation, soundproofing and electrical safeguards are all necessary. Special inspection and handling procedures are required for old film storage. Some production companies have libraries that contain old cellulose nitrate (nitrocellulose) films. These films are no longer made, but those that are in storage are severe fire and life hazards. Nitrocellulose can combust and explode readily.

                                                                                                                                                                                  Computer graphics are common in taped programmes and require long hours at visual display units. Working conditions vary based on the size and layout of the facility. Workspace design requirements are similar to other computer workstations.

                                                                                                                                                                                  Maintenance Shops

                                                                                                                                                                                  Technicians and engineers maintain cameras, recorders, editing machines and other broadcasting equipment, and their working conditions resemble those of their industrial counterparts. Low-residue organic solvents, such as freons, acetone, methanol, methyl ethyl ketone and methylene chloride are used to clean electronic parts and electrical contacts. Metal components are repaired using welding, soldering and power tools. The hazards can include inhalation of solvent vapours and metal fumes, skin contact with solvents, fire and machine hazards. The substitution of safer materials, local exhaust ventilation for solvent vapours and fumes from welding and soldering, as well as machine guards, are all possible safeguards.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 19:25

                                                                                                                                                                                  Motion Picture and Television Production

                                                                                                                                                                                  The motion picture and television industry is found throughout the world. Motion picture production can take place in fixed studios, on large commercial studio lots or on location anywhere. Film production companies range in size from large corporations’ own studios to small companies that rent space in commercial studios. The production of television shows, soap operas, videos and commercials has much in common with motion picture production.

                                                                                                                                                                                  Motion picture production involves many stages and a crew of interacting specialists. The planning stages include obtaining a finished script, determining the budget and schedule, choosing types of location and studios, designing the scene-by-scene appearance of the film, selecting costumes, planning sequence of action and camera locations and lighting schemes.

                                                                                                                                                                                  Once the planning is completed, the detailed process of choosing the location, building sets, gathering the props, arranging the lighting and hiring the actors, stunt performers, special effects operators and other needed support personnel begins. Filming follows the preproduction stage. The final step is film processing and editing, which is not discussed in this article.

                                                                                                                                                                                  Motion picture and television production can involve a wide variety of chemical, electrical and other hazards, many of which are unique to the film industry.

                                                                                                                                                                                  Hazards and Precautions

                                                                                                                                                                                  Filming location

                                                                                                                                                                                  Filming in a studio or on a studio lot has the advantage of permanent facilities and equipment, including ventilation systems, power, lighting, scene shops, costume shops and more control over environmental conditions. Studios can be very large in order to accommodate a variety of filming situations.

                                                                                                                                                                                  Filming on location, especially outdoors in remote locations, is more difficult and hazardous than in a studio because transportation, communications, power, food, water, medical services, living quarters and so on must be provided. Filming on location can expose the film crew and actors to a wide variety of hazardous conditions, including wild animals, poisonous reptiles and plants, civil unrest, climate extremes and adverse local weather conditions, communicable diseases, contaminated food and water, structurally unsafe buildings, and buildings contaminated with asbestos, lead, biological hazards and so on. Filming on water, in the mountains, in deserts and other dangerous locales poses obvious hazards.

                                                                                                                                                                                  The initial survey of possible filming locations should involve evaluating these and other potential hazards to determine the need for special precautions or alternative locations.

                                                                                                                                                                                  Fabricating scenery for motion pictures can involve constructing or modifying a building or buildings, building of indoor and outdoor sets and so on. These can be full size or scaled down. Stages and scenery should be strong enough to bear the loads under consideration (see “Scenery shops” in this chapter).

                                                                                                                                                                                  Life safety

                                                                                                                                                                                  Basic life safety includes ensuring adequate exits, keeping access routes and exits marked and clear of equipment and electrical cables and removal or proper storage and handling of combustible materials, flammable liquids and compressed gases. Dry vegetation around outdoor locations and combustible materials used in filming such as sawdust and tents must be removed or flame-proofed.

                                                                                                                                                                                  Automobiles, boats, helicopters and other means of transportation are common on film locations and a cause of many accidents and fatalities, both when used for transportation and while filming. It is essential that all drivers of vehicles and aircraft be fully qualified and obey all relevant laws and regulations.

                                                                                                                                                                                  Scaffolding and rigging

                                                                                                                                                                                  On location and in studios, lights are rigged to sets, scaffolding or permanent overhead grids, or are free standing. Rigging is also used to fly scenery or people for special effects. Hazards include collapsing scaffolds, falling lights and other equipment and failures of rigging systems.

                                                                                                                                                                                  Precautions for scaffolds include safe construction, guardrails and toeboards, proper supporting of rolling scaffolds and securing of all equipment. Construction, operation, maintenance, inspection and repair of rigging systems should be done only by properly trained and qualified persons. Only assigned personnel should have access to work areas such as scaffolds and catwalks.

                                                                                                                                                                                  Electrical and lighting equipment

                                                                                                                                                                                  Large amounts of power are usually needed for camera lights and everyday electrical needs on a set. In the past direct current (DC) power was used, but alternating current (AC) power is common today. Often, and especially on location, independent sources of power are used. Examples of electrical hazards include shorting of electrical wiring or equipment, inadequate wiring, deteriorated wiring or equipment, inadequate grounding of equipment and working in wet locations. Tie-ins to the power sources and un-ties at the end of filming are two of the most dangerous activities.

                                                                                                                                                                                  All electrical work should be done by licensed electricians and should follow standard electrical safety practices and codes. Safer direct current should be used around water when possible, or ground fault circuit interrupters installed.

                                                                                                                                                                                  Lighting can pose both electrical and health hazards. High-voltage gas discharge lamps such as neons, metal halide lamps and carbon arc lamps are especially hazardous and can pose electrical, ultraviolet radiation and toxic fume hazards.

                                                                                                                                                                                  Lighting equipment should be kept in good condition, regularly inspected and adequately secured to prevent lights from tipping or falling. It is particularly important to check high-voltage discharge lamps for lens cracks that could leak ultraviolet radiation.

                                                                                                                                                                                  Cameras

                                                                                                                                                                                  Camera crews can film in many hazardous situations, including shooting from a helicopter, moving vehicle, camera crane or side of a mountain. Basic types of camera mountings include fixed tripods, dollies for mobile cameras, camera cranes for high shots and insert camera cars for shots of moving vehicles. There have been several fatalities among camera operators while filming under unsafe conditions or near stunts and special effects.

                                                                                                                                                                                  Basic precautions for camera cranes include testing of lift controls, ensuring a stable surface for the crane base and pedestal; properly laid tracking surfaces, ensuring safe distances from high-tension electrical wires; and body harnesses where required.

                                                                                                                                                                                  Insert camera cars that have been engineered for mounting of cameras and towing of the vehicle to be filmed are recommended instead of mounting cameras on the outside of the vehicle being filmed. Special precautions include having a safety checklist, limiting the number of personnel on the car, rigging done by experts, abort procedures and having a dedicated radio communications procedure.

                                                                                                                                                                                  Actors, extras and stand-ins

                                                                                                                                                                                  See the article “Actors” in this chapter.

                                                                                                                                                                                  Costumes

                                                                                                                                                                                  Costumes are made and cared for by wardrobe attendants, who may be exposed to a wide variety of dyes and paints, hazardous solvents, aerosol sprays and so on, often without ventilation.

                                                                                                                                                                                  Hazardous chlorinated cleaning solvents should be replaced with safer solvents such as mineral spirits. Adequate local exhaust ventilation should be used when spraying dyes or using solvent-containing materials. Mixing of powders should be done in an enclosed glove box.

                                                                                                                                                                                  Special effects

                                                                                                                                                                                  A wide variety of special effects are used in motion picture production to simulate real events that would otherwise be too dangerous, impractical or expensive to execute. These include fogs, smoke, fire, pyrotechnics, firearms, snow, rain, wind, computer-generated effects and miniature or scaled-down sets. Many of these have significant hazards. Other hazardous special effects can involve the use of lasers, toxic chemicals such as mercury to give silvery effects, flying objects or people with rigging and electric hazards associated with rain and other water effects. Appropriate precautions would need to be taken with such special effects.

                                                                                                                                                                                  General precautions for hazardous special effects include adequate preplanning, having written safety procedures, using adequately trained and experienced operators and the least hazardous special effects possible, coordinating with the fire department and other emergency services, making everyone aware of the intended use of special effects (and being able to refuse to participate), not allowing children in the vicinity, running detailed rehearsals with testing of the effects, clearing the set of all but essential personnel, having a dedicated emergency communications system, minimizing the number of retakes and having procedures ready to abort production.

                                                                                                                                                                                  Pyrotechnics are used to create effects involving explosions, fires, light, smoke and sound concussions. Pyrotechnics materials are usually low explosives (mostly Class B), including flash powder, flash paper, gun cotton, black powder and smokeless powder. They are used in bullet hits (squibs), blank cartridges, flash pots, fuses, mortars, smoke pots and many more. Class A high explosives, such as dynamite, should not be used, although detonating cord is sometimes used. The major problems associated with pyrotechnics include premature triggering of the pyrotechnic effect; causing a fire by using larger quantities than needed; lack of adequate fire extinguishing capabilities; and having inadequately trained and experienced pyrotechnics operators.

                                                                                                                                                                                  In addition to the general precautions, special precautions for explosives used in pyrotechnics include proper storage, the use of appropriate type and in smallest amounts necessary to achieve the effect, and testing them in the absence of spectators. When pyrotechnics are used smoking should be banned and firefighting equipment and trained personnel should be on hand. The materials should be set off by electronic firing controls and adequate ventilation is needed.

                                                                                                                                                                                  The uses of fire effects range from ordinary gas stoves and fireplaces to the destructive fires involved in burning cars, houses, forests and even people (figure 1). In some cases, fires can be simulated by flickering lights and other electronic effects. Materials used to create fire effects include propane gas burners, rubber cement, gasoline and kerosene. They are often used in conjunction with pyrotechnic special effects. Hazards are directly related to the fire getting out of control and the heat they generate. Poor maintenance of fire generating equipment and the excessive use of flammable materials or the presence of other unintended combustible materials, and improper storage of combustible and flammable liquids and gases are all risks. Inexperienced special effects operators can also be a cause of accidents as well.

                                                                                                                                                                                  Figure 1. Fire special effect

                                                                                                                                                                                  ENT230F1

                                                                                                                                                                                  William Avery

                                                                                                                                                                                  Special precautions are similar to those needed for pyrotechnics, such as replacing gasoline, rubber cement and other flammable substances with the safer combustible gels and liquid fuels which have been developed in recent years. All materials in the fire area should be non-combustible or flame-proofed. This precaution includes flame-proofed costumes for actors in the vicinity.

                                                                                                                                                                                  Fogs and smoke effects are common in filming. Dry ice (carbon dioxide), liquid nitrogen, petroleum distillates, zinc chloride smoke generators (which might also contain chlorinated hydrocarbons), ammonium chloride, mineral oil, glycol fogs and water mists are common fog-generating substances. Some materials used, such as petroleum distillates and zinc chloride, are severe respiratory irritants and can cause chemical pneumonia. Dry ice, liquid nitrogen and water mists represent the least chemical hazards, although they can displace oxygen in enclosed areas, possibly making the air unfit for supporting life, especially in enclosed areas. Microbiological contamination can be a problem associated with water-mist generating systems. Some evidence is forthcoming that respiratory irritation is possible from those fogs and smokes that were thought to be safest, such as mineral oil and glycols.

                                                                                                                                                                                  Special precautions include eliminating the most hazardous fogs and smoke; using a fog with the machine designed for it; limiting duration of use, including limiting the number of retakes; and avoiding use in enclosed spaces. Fogs should be exhausted as soon as possible. Respiratory protection for the camera crew should be provided.

                                                                                                                                                                                  Firearms are common in films. All types of firearms are used, ranging from antique firearms to shotguns and machine guns. In many countries (not including the United States) live ammunition is banned. However, blank ammunition, which is commonly used in conjunction with live bullet hits in order to simulate actual bullet impacts, has caused many injuries and fatalities. Blank ammunition used to consist of a metal casing with a percussion primer and smokeless powder topped with a paper wad, which could be ejected at high velocity when fired. Some modern safety blanks use special plastic inserts with a primer and flash powder, giving only a flash and noise. Blank ammunition is commonly used in conjunction with bullet hits (squibs), consisting of a plastic-cased detonator imbedded in the object to be struck by the bullet to simulate actual bullet impacts. Hazards, besides the use of live ammunition, include the effects of use of blanks at close range, mixing up live and blank ammunition or using the wrong ammunition in a firearm. Improperly modified firearms can be dangerous, as can the lack of adequate training in the use of blank-firing firearms.

                                                                                                                                                                                  Live ammunition and unmodified firearms should be banned from a set and non-firing facsimile weapons used whenever possible. Firearms that can actually fire a bullet should not be used, only proper safety blanks. Firearms should be checked regularly by the property master or other firearms expert. Firearms should be locked away, as should all ammunition. Guns should never be pointed at actors in a scene, and the camera crew and others in close proximity to the set should be protected with shields from blanks fired from weapons.

                                                                                                                                                                                  Stunts

                                                                                                                                                                                  A stunt can be defined as any action sequence that involves a greater than normal risk of injury to performers or others on the set. With increasing demands for realism in films, stunts have become very common. Examples of potentially hazardous stunts include high falls, fights, helicopter scenes, car chases, fires and explosions. About half the fatalities occurring during filming are stunt-related, often also involving special effects.

                                                                                                                                                                                  Stunts can endanger not only the stunt performer but often the camera crew and other performers may be injured as well. Most of the general precautions described for special effects also apply to stunts. In addition, the stunt performer should be experienced in the type of stunt being filmed. A stunt coordinator should be in charge of all stunts since a person cannot perform a stunt and be in adequate control of safety, especially when there are several stunt performers.

                                                                                                                                                                                  Aircraft, especially helicopters, have been involved in the most serious multiple fatality accidents in motion picture production. Pilots are often not adequately qualified for stunt flying. Acrobatic manoeuvres, hovering close to the ground, flying too close to sets using pyrotechnics and filming from helicopters with open doors or from the pontoons without adequate fall protection are some of the most dangerous situations. See the article “Helicopters” elsewhere in the Encyclopaedia.

                                                                                                                                                                                  One precaution is to employ an independent aviation consultant, in addition to the pilot, to recommend and oversee safety procedures. Restriction of personnel within 50 feet of grounded aircraft and clear written procedures for filming on ground near aircraft with their engines running or during aircraft landings or takeoffs are other safety measures. Coordination with any pyrotechnics or other hazardous special effects operators is essential, as are procedures to ensure the safety of camera operators filming from aircraft. Procedures for aborting an operation are needed.

                                                                                                                                                                                  Vehicle action sequences have also been a source of many accidents and fatalities. Special effects, such as explosions, crashes, driving into rivers and car chase scenes with multiple cars, are the most common cause of accidents. Motorcycle scenes can be even more hazardous than automobiles because the operator of the motorcycle suffers from the lack of personal protection.

                                                                                                                                                                                  Special precautions include using camera cars. Using stunt drivers for all cars in a stunt scene can lower the accident rate, as can special training for non-stunt passengers. Other safety rules include proper safety equipment, inspection of all ramps and other equipment to be used during a stunt, using dummies in cars during crashes, explosions and other extremely high risk sequences and not driving cars directly towards cameras if there is a camera operator behind the camera. See figure 2 for an example of using dummies in a roller coaster stunt. Adequate ventilation is needed for automobiles that are being filmed indoors with engines running. Stunt motorcycles should be equipped with a deadman switch so that the motor shuts off when the rider separates from the motorcycle.

                                                                                                                                                                                  Figure 2. Using dummies for a roller coaster stunt.

                                                                                                                                                                                  ENT230F4

                                                                                                                                                                                  William Avery

                                                                                                                                                                                  Stunts using fire and explosion place performers at higher risk and require special precautions beyond those used just for the special effects. Protection for stunt performers directly exposed to flames includes wearing a protective barrier gel (e.g., Zel Jel) on the hair, the skin, clothing and so on. Proper protective clothing, including fireproof suits under costumes; flame-resistant gloves and boots; and sometimes hidden oxygen tanks, should be supplied. Specially trained personnel equipped with carbon dioxide fire extinguishers should be on hand in case of an emergency.

                                                                                                                                                                                  Fight scenes can involve performers in fistfights or other unarmed combat or the use of knives, swords, firearms and other combat equipment. Many film and stage fights do not involve the use of stunt performers, thus increasing the risk of injury because of the lack of training.

                                                                                                                                                                                  Simulated weapons, such as knives and swords with retractable blades, are one safeguard. Weapons should be stored carefully. Training is key. The performer should know how to fall and how to use specific weapons. Adequate choreography and rehearsals of the fights is needed, as is proper protective clothing and equipment. A blow should never be aimed directly at an actor. If a fight involves a high degree of hazard, such as falling down a flight of stairs or crashing through a window, a professional stunt double should be used.

                                                                                                                                                                                  Falls in stunts can range from falling down a flight of stairs to falling off a horse, being thrown through the air by a trampoline or ratchet catapult system, or a high fall off a cliff or building (figure 3). There have been many injuries and fatalities from poorly prepared falls.

                                                                                                                                                                                  Figure 3. High fall stunt.

                                                                                                                                                                                  ENT230F3

                                                                                                                                                                                  Only experienced stunt performers should attempt fall stunts. When possible, the fall should be simulated. For example, falling down a flight of stairs can be filmed a few stairs at a time so the stunt performer is never out of control, or a fall off a tall building simulated by a fall of a few feet onto a net and using a dummy for the rest of the fall. Precautions for high falls involve a high fall coordinator and a specialized fall/arrest system for safe deceleration. Falls of more than 15 feet require two safety spotters. Other precautions for falls include airbags, crash pads of canvas filled with sponge rubber, sand pits and so on, depending on the type of fall. Testing of all equipment is crucial.

                                                                                                                                                                                  Animal scenes are potentially very hazardous because of the unpredictability of animals. Some animals, such as large cats, can attack if startled. Large animals like horses can be a hazard just because of their size. Dangerous, untrained or unhealthy animals should not be used on sets. Venomous reptiles such as rattlesnakes are particularly hazardous. In addition to the hazards to personnel, the health and safety of the animals should be considered.

                                                                                                                                                                                  Only trained animal handlers should be allowed to work with animals. Adequate conditions for the animals are needed, as is basic animal safety equipment, such as fire extinguishers, fire hoses, nets and tranquilizing equipment. Animals should be allowed adequate time to become familiar with the set, and only required personnel should be permitted on the set. Conditions that could upset animals should be eliminated and animals kept from exposure to loud noises or light flashes whenever possible, thus ensuring the animals will not be injured and will not become unmanageable. Certain situations—for example, those using venomous reptiles or large numbers of horses—will require special precautions.

                                                                                                                                                                                  Water stunts can include diving, filming in fast-moving water, speedboat stunts and sea battles. Hazards include drowning, hypothermia in cold water, underwater obstructions and contaminated water. Emergency teams, including certified safety divers, should be on hand for all water stunts. Diver certification for all performers or camera operators using self-contained underwater breathing apparatus (SCUBA) and provision of standby breathing equipment are other precautions. Emergency decompression procedures for dives over 10 m should be in place. Safety pickup boats for rescue and proper safety equipment, such as use of nets and ropes in fast-moving water, are needed.

                                                                                                                                                                                  Health and Safety Programmes

                                                                                                                                                                                  Most major film studios have a full-time health and safety officer to oversee the health and safety programme. Problems of responsibility and authority can occur, however, when a studio rents facilities to a production company, as is increasingly common. Most production companies do not have a health and safety programme. A health and safety officer, with authority to establish safety procedures and to ensure they are carried out, is essential. There is a need to coordinate the activities of others charged with production planning, such as stunt coordinators, special effects operators, firearms experts and the key grip (who is usually the individual most responsible for the safety of sets, cameras, scaffolding, etc.), each of whom has specialized safety knowledge and experience. A health and safety committee that meets regularly with representatives from all departments and unions can provide a conduit between the management and employees. Many unions have an independent health and safety committee which can be a source of health and safety expertise.

                                                                                                                                                                                  Medical services

                                                                                                                                                                                  Both non-emergency and emergency medical services are essential during film production. Many film studios have a permanent medical department, but most production companies do not. The first step in determining the degree of on-location medical services to be provided is a needs assessment, to identify potential medical risks, including the need for vaccination in certain countries, possible local endemic diseases, evaluation of local environmental and climate conditions, and an evaluation of the quality of local medical resources. The second, pre-planning stage involves a detailed analysis of major risks and availability of adequate emergency and other medical care in order to determine what type of emergency planning is essential. In situations where there are high risks and/or remote locations, trained emergency physicians would be needed on location. Where there is quick access to adequate emergency facilities, paramedics or emergency medical technicians with advanced training would suffice. In addition, adequate emergency transportation should be arranged beforehand. There have been several fatalities due to the lack of adequate emergency transportation (Carlson 1989; McCann 1989).

                                                                                                                                                                                  Standards

                                                                                                                                                                                  There are few occupational safety and health regulations aimed specifically at the film production industry. However, many general regulations, such as those affecting fire safety, electrical hazards, scaffolding, lifts, welding and so on, are applicable. Local fire departments generally require special fire permits for filming and may require that standby fire personnel be present on filming sites.

                                                                                                                                                                                  Many productions have special requirements for the licensing of certain special effects operators, such as pyrotechnicians, laser operators and firearms users. There can be regulations and permits required for specific situations, such as the sale, storage and use of pyrotechnics, and the use of firearms.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 19:22

                                                                                                                                                                                  Scenery Shops

                                                                                                                                                                                  Theatres, motion pictures, television, theme and amusement parks and similar entertainment enterprises all build and paint scenery and make props for their presentations. In many cases, these are made in-house. There are also commercial scenic shops that specialize in making large scenery which is then transported to the site. The major difference between making scenery backstage in a small theatre and building huge sets or even houses for a motion picture, for example, is the scale of the work and who does the work. In small theatres, there is little division of tasks, whereas in larger facilities, there would be a division of labour among carpenters, scenic painters, welders, prop makers and so on.

                                                                                                                                                                                  The scenery for a theatre play, motion picture set or television studio might look realistic, but is often an illusion. The walls of a room are usually not solid but are composed of lightweight flats (panels of painted canvas stretched on wooden frames). Background scenery often consists of backdrops (huge curtains painted to represent the background) which can be lowered and raised for different scenes. Other solid-looking props, such as trees, rocks, vases, mouldings, sculptures and so forth, might be made out of papier mâché, plaster, polyurethane foam or other materials. Today, a wide variety of materials are used to make scenery, including wood, metal, plastics, synthetic fabrics, paper and other modern industrial products. For scenery which performers will walk or climb on, the structures must be solid and meet proper safety standards.

                                                                                                                                                                                  The basic processes and chemicals used for making sets and props tend to be similar for the various types of entertainment facilities. Outdoor sets, however, can often use heavy construction materials such as cement on a large scale, which would be impractical inside due to smaller load-bearing capacities. The degree of hazard depends on the types and amounts of chemicals used, and the precautions taken. A theatre might use quarts of polyurethane foam resin for making small props, while the inside of a tunnel in a theme park set might use hundreds of gallons of the resin. Small in-house shops tend to have less awareness of the hazards, and overcrowding often creates additional hazards due to the proximity of incompatible processes such as welding and use of flammable solvents.

                                                                                                                                                                                  Woodworking

                                                                                                                                                                                  Wood, plywood, particle board and Plexiglas are commonly used in constructing sets. Hazards include: accidents with woodworking machinery, power tools and hand tools; electrical shock; fire from combustible wood dust; and toxic effects from inhalation of wood dust, formaldehyde and methyl methacrylate decomposition products from machining plywood, particle board and Plexiglas, and solvents used with contact adhesives.

                                                                                                                                                                                  Precautions include machine guards, proper electrical safety, housekeeping and adequate storage to reduce fire hazards, dust collectors, adequate ventilation and eye protection.

                                                                                                                                                                                  Welding, Cutting and Brazing

                                                                                                                                                                                  Steel and aluminium frameworks are commonly used for the construction of sets. These are often welded using oxyacetylene torches and arc welders of various types. Injury hazards include fire from flying sparks, fire and explosion from compressed gases, and electrical shock from arc welders; health hazards include metal fumes, fluxes, welding gases (ozone, nitrogen oxides, carbon monoxide) and ultraviolet radiation.

                                                                                                                                                                                  Precautions include removal or protection of combustible materials, proper storage and handling of compressed gas cylinders, electrical safety, adequate ventilation and personal protective equipment.

                                                                                                                                                                                  Scenic Painting

                                                                                                                                                                                  Paints, lacquers, varnishes, dye solutions and other coatings are used for painting scenery flats and fabric drops. The paints and dye solutions can be either solvent based or water based. Powdered pigments and dyes are usually mixed in the shop, with the use of lead chromate pigments still being common. Large flats and drops are often sprayed. Solvents are used for dissolving dyes and resins, thinning, removing paint and other coatings and for cleaning tools, brushes and even hands. Hazards include skin contact with solvents and inhalation of solvent vapours, spray mists and powdered dyes and pigments. Solvents are also fire hazards, particularly when sprayed.

                                                                                                                                                                                  Precautions include elimination of lead pigments, using water-based paints and dyes, adequate ventilation for use of solvents, respiratory protection for spraying, proper storage and handling of flammable liquids and proper disposal of waste solvents and paints.

                                                                                                                                                                                  Plastic Resins

                                                                                                                                                                                  Polyurethane foam resins, epoxy resins, polyester resins and other resins are commonly used to make large sets and props. Spraying of polyurethane foam resins containing diphenylmethane diisocyanate (MDI) is particularly dangerous, with hazards of chemical pneumonia and asthma. Epoxy resins, polyester resins and solvents have skin, eye and inhalation hazards, and are fire hazards.

                                                                                                                                                                                  Precautions include substitution of safer materials (such as cement or celastic instead of spray polyurethane foams, or water-based materials to replace solvent-based types), local exhaust ventilation, proper storage and handling, proper disposal of waste materials and adequate personal protective equipment.

                                                                                                                                                                                  Props and Models

                                                                                                                                                                                  Plastic resins are also used to make body armour, face masks, breakaway glass and other props and models, as are wood, plaster, metal, plastics and so on. A variety of water-based and solvent-based adhesives are also used. Solvents are used in cleanup. Precautions are similar to those already discussed.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Thursday, 24 March 2011 19:18

                                                                                                                                                                                  Theatre and Opera

                                                                                                                                                                                  Occupational safety and health in the theatre and opera comprises diverse aspects, including all the problems of industry in general plus specific artistic and cultural aspects. More than 125 different professions are involved in the process of making theatre or opera performances; these performances can take place in classrooms and small theatres, as well as large opera houses or convention halls. Very often theatre and opera companies tour around the country and abroad, performing in diverse buildings.

                                                                                                                                                                                  There are the artistic professions—artists, actors, singers (soloists and choirs), musicians, dancers, coaches, choreographers, conductors and directors; the technical and production professions—technical directors and managers, lighting manager, chief electrician, sound engineer, chief machinist, armourer, wigmaster, dyeing and wardrobe director, property maker, costume maker and others; and the administrative professions—chief accountant, personnel managers, house managers, catering managers, contracts managers, marketing personnel, box office personnel, advertising managers and so on.

                                                                                                                                                                                  The theatre and opera involve general industrial safety hazards such as lifting of heavy objects and accident risks as a result of irregular working hours, combined with factors specific to the theatre, such as the layout of the premises, complex technical arrangements, bad lighting, extreme temperatures and the need to work to tight schedules and meet deadlines. These risks are the same for artists and technical personnel.

                                                                                                                                                                                  A serious attitude towards occupational safety and health demands taking care of the hand of a violinist or the wrist of a ballet dancer, as well as a broader view of the situation of theatre employees as a whole, including both physical and psychological risks. Theatre buildings are also open to the public, and this aspect of safety and health must be taken care of.

                                                                                                                                                                                  Fire Safety

                                                                                                                                                                                  There are many types of potential fire hazards in theatres and opera houses. These include: general hazards such as blocked or locked exits, inadequate number and size of exits, lack of training in procedures in the event of fire; backstage hazards such as improper storage of paints and solvents, unsafe storage of scenery and other combustibles, welding in close proximity to combustible materials and lack of proper exits for dressing rooms; on-stage hazards such as pyrotechnics and open flames, lack of fireproofing of drapes, decorations, props and scenery, and lack of stage exits and sprinkler systems; and audience hazards such as permitting smoking, blocked aisles and exceeding the legal number of occupants. In case of a fire in the theatre building all aisles, passages and staircases must be kept entirely free from chairs or any other obstructions, to help evacuation. Fire escapes and emergency exits must be marked. The alarm bells, fire alarms, fire extinguishers, sprinkler systems, heat and smoke detectors and emergency lights must function. The fire curtain must be lowered and raised in the presence of each audience, unless a deluge sprinkler system is installed. When the audience must leave, whether in an emergency or at the end of a performance, all exit doors must be open.

                                                                                                                                                                                  Fire safety procedures must be established and fire drills held. One or more trained fire guards must be present at all performances unless the fire department assigns firefighters. All scenery, props, drapes and other combustible materials present on the stage must be fireproofed. If pyrotechnics or open flames are present, fire permits must be obtained when required and safe procedures established for their use. Stage and backstage lighting equipment and electrical systems must meet standards and be properly maintained. Combustible materials and other fire hazards should be removed. Smoking should not be allowed in any theatre except in properly designated areas.

                                                                                                                                                                                  Grids and Rigging

                                                                                                                                                                                  Theatre and opera stages have overhead grids from which lights are hung, and rigging systems to fly (raise and lower) scenery and sometimes performers. There are ladders and overhead catwalks for lighting technicians and others to work overhead. On the stage, discipline is required from both the artists and the technical staff because of all the hanging equipment above. Theatre scenery can be moved vertically and horizontally. Horizontal movement of scenery at the side of the stage can be done manually or mechanically through the ropes from the grids in the rope house. Safety routines are very important in rope and counterweight flying. There are different kinds of rigging systems, using hydraulic and electric power. Rigging should be done by trained and qualified personnel. Safety procedures for rigging include: inspection of all rigging equipment before use and after alterations; ensuring load capacities are not exceeded; following safe procedures when loading, unloading or operating rigging systems; maintaining visual contact with a moving piece at all times; warning everyone before moving any rigged object; and ensuring no one is underneath when moving scenery. The lighting crew must take appropriate safety measures while mounting, connecting and directing spotlights (figure 1). Lights should be fastened to the grid with safety chains. Safety shoes and helmets should be worn by personnel working on stage when any work is proceeding overhead.

                                                                                                                                                                                  Figure 1. Arranging lights in a lowered lighting grid.

                                                                                                                                                                                  ENT220F1

                                                                                                                                                                                  William Avery

                                                                                                                                                                                  Costumes and Makeup

                                                                                                                                                                                  Costumes

                                                                                                                                                                                  Costumes can be made in the theatres’ own ateliers by the wardrobe attendants. It is a heavy job, especially the handling and transportation of old classical costumes. Body aches, headaches, musculoskeletal strains and sprains and other injuries can result from operating sewing machines, dryers, irons, ironing boards and electrical equipment; dust from textiles is a health hazard. Cleaning and dying of costumes, wigs and shoes can use a variety of hazardous liquid solvents and aerosol sprays.

                                                                                                                                                                                  Wearing heavy costumes can be hot under stage lights. Frequent costume changes between scenes can be a source of stress. If flames are present, fireproofing of costumes is essential.

                                                                                                                                                                                  Precautions for wardrobe attendants include proper electrical safety; adequate lighting and ventilation for solvents and spraying; adequate adjustable chairs, work tables and ironing boards; and knowledge of textiles health hazards.

                                                                                                                                                                                  Makeup

                                                                                                                                                                                  Performers usually have to wear heavy layers of makeup for several hours for every performance. Application of makeup and hair styling is usually done by makeup and hair artists in commercial theatre and opera. Often the makeup artist has to work on several performers in a short period of time. Makeup can contain a wide variety of solvents, dyes and pigments, oils, waxes and other ingredients, many of which can cause skin or eye irritation or allergies. Special effects makeup can involve the use of hazardous adhesives and solvents. Eye injuries can result from abrasions during application of eye makeup. Shared makeup is a concern for transmission of bacterial contamination (but not hepatitis or HIV). The use of aerosol hair sprays in enclosed dressing rooms is an inhalation hazard. For makeup removal, large quantities of cold creams are used; solvents are also used for removing special effects makeup.

                                                                                                                                                                                  Precautions include washing off the makeup with soap after every performance, cleaning of brushes and sponges or using disposable ones, using individual applicators for makeup and keeping all makeup cold. The makeup room must have mirrors, flexible lighting and adequate chairs.

                                                                                                                                                                                  Setting Up and Striking Sets

                                                                                                                                                                                  Scenery at a theatre may require one standing set, which can be constructed of heavy materials; more frequently there can be several changes of scenery during a performance, requiring movability. Similarly, for a repertory theatre, changeable scenery can be constructed which is easily transportable. Scenery can be built on wheels, for mobility.

                                                                                                                                                                                  Stage crews risk injury when building, disassembling and moving scenery, and when moving counterbalances. Hazards include back, leg and arm injuries. Accidents often occur when breaking down (striking) the set when a show’s run is over, due to fatigue. Precautions include wearing hard hats and safety shoes, safe lifting procedures and equipment, banning of unnecessary personnel and not working when fatigued.

                                                                                                                                                                                  For scene decorators or painters painting, nailing and laying out backdrops, paint and other chemicals are also health hazards. For carpenters, unsafe worksites, noise and vibration as well as air contamination are all problems. Wig and mask makers generally have problems with working postures as well as health risks associated with the use of resins—for example, when working on bald heads and false noses. Health risks include toxic chemicals and possible allergies, skin irritation and asthmatic complaints.

                                                                                                                                                                                  Regulations

                                                                                                                                                                                  There are often national laws, for example, building codes, and local regulations for fire safety. For grids and rigging, directives from the European Economic Commission—for instance, on machinery (89/392 EEC) and on lifting appliances for persons—may influence national legislation. Other countries also have safety and health legislation that can affect theatres and opera houses.

                                                                                                                                                                                   

                                                                                                                                                                                  Back

                                                                                                                                                                                  Page 48 of 122

                                                                                                                                                                                  " DISCLAIMER: The ILO does not take responsibility for content presented on this web portal that is presented in any language other than English, which is the language used for the initial production and peer-review of original content. Certain statistics have not been updated since the production of the 4th edition of the Encyclopaedia (1998)."

                                                                                                                                                                                  Contents

                                                                                                                                                                                  Transport Industry and Warehousing References

                                                                                                                                                                                  American National Standards Institute (ANSI). 1967. Illumination. ANSI A11.1-1967. New York: ANSI.

                                                                                                                                                                                  Anton, DJ. 1988. Crash dynamics and restraint systems. In Aviation Medicine, 2nd edition, edited by J Ernsting and PF King. London: Butterworth.

                                                                                                                                                                                  Beiler, H and U Tränkle. 1993. Fahrerarbeit als Lebensarbeitsperpektive. In Europäische Forschungsansätze zur Gestaltung der Fahrtätigkeit im ÖPNV (S. 94-98) Bundesanstat für Arbeitsschutz. Bremerhaven: Wirtschaftsverlag NW.

                                                                                                                                                                                  Bureau of Labor Statistics (BLS). 1996. Safety and Health Statistics. Washington, DC: BLS.

                                                                                                                                                                                  Canadian Urban Transit Association. 1992. Ergonomic Study of the Driver’s Workstation in Urban Buses. Toronto: Canadian Urban Transit Association.

                                                                                                                                                                                  Decker, JA. 1994. Health Hazard Evaluation: Southwest Airlines, Houston Hobby Airport, Houston, Texas. HETA-93-0816-2371. Cincinnati, OH: NIOSH.

                                                                                                                                                                                  DeHart RL. 1992. Aerospace medicine. In Public Health and Preventive Medicine, 13th edition, edited by ML Last and RB Wallace. Norwalk, CT: Appleton and Lange.

                                                                                                                                                                                  DeHart, RL and KN Beers. 1985. Aircraft accidents, survival, and rescue. In Fundamentals of Aerospace Medicine, edited by RL DeHart. Philadelphia, PA: Lea and Febiger.

                                                                                                                                                                                  Eisenhardt, D and E Olmsted. 1996. Investigation of Jet Exhaust Infiltration into a Building Located on John F. Kennedy (JFK) Airport Taxiway. New York: US Department of Health and Human Services, Public Health Service, Division of Federal Occupational Health, New York Field Office.

                                                                                                                                                                                  Firth, R. 1995. Steps to successfully installing a warehouse management system. Industrial Engineering 27(2):34–36.

                                                                                                                                                                                  Friedberg, W, L Snyder, DN Faulkner, EB Darden, Jr., and K O’Brien. 1992. Radiation Exposure of Air Carrier Crewmembers II. DOT/FAA/AM-92-2.19. Oklahoma City, OK: Civil Aeromedical Institute; Washington, DC: Federal Aviation Administration.

                                                                                                                                                                                  Gentry, JJ, J Semeijn, and DB Vellenga. 1995. The future of road haulage in the new European Union—1995 and beyond. Logistics and Transportation Review 31(2):149.

                                                                                                                                                                                  Giesser-Weigt, M and G Schmidt. 1989. Verbesserung des Arbeitssituation von Fahrern im öffentlichen Personennahverkehr. Bremerhaven: Wirtschaftsverlag NW.

                                                                                                                                                                                  Glaister, DH. 1988a. The effects of long duration acceleration. In Aviation Medicine, 2nd edition, edited by J Ernsting and PF King. London: Butterworth.

                                                                                                                                                                                  —. 1988b. Protection against long duration acceleration. In Aviation Medicine, 2nd edition, edited by J Ernsting and PF King. London: Butterworth.

                                                                                                                                                                                  Haas, J, H Petry and W Schühlein. 1989. Untersuchung zurVerringerung berufsbedingter Gesundheitsrisien im Fahrdienst des öffentlichen Personennahverkehr. Bremerhaven; Wirtschaftsverlag NW.

                                                                                                                                                                                  International Chamber of Shipping. 1978. International Safety Guide for Oil Tankers and Terminals. London: Witherby.

                                                                                                                                                                                  International Labour Organization (ILO). 1992. Recent Developments in Inland Transportation. Report I, Sectoral Activities Programme, Twelfth Session. Geneva: ILO.

                                                                                                                                                                                  —. 1996. Accident Prevention on Board Ship at Sea and in Port. An ILO Code of Practice. 2nd edition. Geneva: ILO.

                                                                                                                                                                                  Joyner, KH and MJ Bangay. 1986. Exposure survey of civilian airport radar workers in Australia. Journal of Microwave Power and Electromagnetic Energy 21(4):209–219.

                                                                                                                                                                                  Landsbergis, PA, D Stein, D Iacopelli and J Fruscella. 1994. Work environment survey of air traffic controllers and development of an occupational safety and health training program. Presented at the American Public Health Association, 1 November, Washington, DC.

                                                                                                                                                                                  Leverett, SD and JE Whinnery. 1985. Biodynamics: Sustained acceleration. In Fundamentals of Aerospace Medicine, edited by RL DeHart. Philadelphia, PA: Lea and Febiger.

                                                                                                                                                                                  Magnier, M. 1996. Experts: Japan has the structure but not the will for intermodalism. Journal of Commerce and Commercial 407:15.

                                                                                                                                                                                  Martin, RL. 1987. AS/RS: From the warehouse to the factory floor. Manufacturing Engineering 99:49–56.

                                                                                                                                                                                  Meifort, J, H Reiners, and J Schuh. 1983. Arbeitshedingungen von Linienbus- und Strassenbahnfahrern des Dortmunder Staatwerke Aktiengesellschaft. Bremen- haven: Wirtschaftsverlag.

                                                                                                                                                                                  Miyamoto, Y. 1986. Eye and respiratory irritants in jet engine exhaust. Aviation, Space and Environmental Medicine 57(11):1104–1108.

                                                                                                                                                                                  National Fire Protection Association (NFPA). 1976. Fire Protection Handbook, 14th edition. Quincy, MA: NFPA.

                                                                                                                                                                                  National Institute for Occupational Safety and Health (NIOSH). 1976. Documented Personnel Exposures from Airport Baggage Inspection Systems. DHHS (NIOSH) Publication 77-105. Cincinnati, OH: NIOSH.

                                                                                                                                                                                  —. 1993a. Health Hazard Evaluation: Big Bear Grocery Warehouse. HETA 91-405-2340. Cincinnati, OH: NIOSH.

                                                                                                                                                                                  —. 1993b. Alert: Preventing Homicide in the Workplace. DHHS (NIOSH) Publication 93-108. Cincinatti, OH: NIOSH.

                                                                                                                                                                                  —. 1995. Health Hazard Evaluation: Kroger Grocery Warehouse. HETA 93-0920-2548. Cincinnati, OH: NIOSH.

                                                                                                                                                                                  National Safety Council. 1988. Aviation Ground Operation Safety Handbook, 4th edition. Chicago, IL: National Safety Council.

                                                                                                                                                                                  Nicogossian, AE, CL Huntoon and SL Pool (eds.). 1994. Space Physiology and Medicine, 3rd edition. Philadelphia, PA: Lea and Febiger.

                                                                                                                                                                                  Peters, Gustavsson, Morén, Nilsson and Wenäll. 1992. Forarplats I Buss, Etapp 3; Kravspecifikation. Linköping, Sweden: Väg och Trafikinstitutet.

                                                                                                                                                                                  Poitrast, BJ and deTreville. 1994. Occupational medical considerations in the aviation industry. In Occupational Medicine, 3rd edition, edited by C Zenz, OB Dickerson, and EP Hovarth. St. Louis, MO: Mosby.

                                                                                                                                                                                  Register, O. 1994. Make Auto-ID work in your world. Transportation and Distribution 35(10):102–112.

                                                                                                                                                                                  Reimann, J. 1981. Beanspruchung von Linienbusfahrern. Untersuchungen zur Beanspruchung von Linienbusfahrern im innerstädtischen Verkehr. Bremerhaven: Wirtschafts-verlag NW.

                                                                                                                                                                                  Rogers, JW. 1980. Results of FAA Cabin Ozone Monitoring Program in Commercial Aircraft in 1978 and 1979. FAA-EE-80-10. Washington, DC: Federal Aviation Administration, Office of Environment and Energy.

                                                                                                                                                                                  Rose, RM, CD Jenkins, and MW Hurst. 1978. Air Traffic Controller Health Change Study. Boston, MA: Boston University School of Medicine.

                                                                                                                                                                                  Sampson, RJ, MT Farris, and DL Shrock. 1990. Domestic Transportation: Practice, Theory, and Policy, 6th edition. Boston, MA: Houghton Mifflin Company.

                                                                                                                                                                                  Streekvervoer Nederland. 1991. Chaufferscabine [Driver’s cabin]. Amsterdam, Netherlands: Streekvervoer Nederland.

                                                                                                                                                                                  US Senate. 1970. Air Traffic Controllers (Corson Report). Senate Report 91-1012. 91st Congress, 2nd Session, 9 July. Washington, DC: GPO.

                                                                                                                                                                                  US Department of Transportation (DOT). 1995. Senate Report 103–310, June 1995. Washington, DC: GPO.

                                                                                                                                                                                  Verband Deutscher Verkehrsunternehmen. 1996. Fahrerarbeitsplatz im Linienbus [Driver’s workstation in buses]. VDV Schrift 234 (Entwurf). Cologne, Germany: Verband Deutscher Verkehrsunternehmen.

                                                                                                                                                                                  Violland, M. 1996. Whither railways? OECD Observer No. 198, 33.

                                                                                                                                                                                  Wallentowitz H, M Marx, F Luczak, J Scherff. 1996. Forschungsprojekt. Fahrerarbeitsplatz im Linienbus— Abschlußbericht [Research project. Driver’s workstation in buses—Final report]. Aachen, Germany: RWTH.

                                                                                                                                                                                  Wu, YX, XL Liu, BG Wang, and XY Wang. 1989. Aircraft noise-induced temporary threshold shift. Aviation Space and Medicine 60(3):268–270.